Browse > Article
http://dx.doi.org/10.5302/J.ICROS.2006.12.12.1249

New Start-Up Logic for Microturbine by Constant Power Control under an Extremely Low Temperature  

Rho, Min-Sik (신라대학교 전자공학과)
Publication Information
Journal of Institute of Control, Robotics and Systems / v.12, no.12, 2006 , pp. 1249-1255 More about this Journal
Abstract
This paper presents a constant power control logic for perfect starting a microtubine in vehicle. Under extremely low temperature, performance of the start-up system is severely dropped than that of room temperature because of increasing of load of mechanical parts including engine core and drop of the lead-acid battery capacity. Unfortunately, performance drop of lead-acid battery makes severe problems that cause a malfunction of fuel and lubrication system and power fail of digital devices. So we propose the new start-up logic by constant output power control of lead-acid battery using PWM inverter controller for preventing above problems and keeping good performance of start-up system for microturbine. Also, we prove usefulness of new start-up logic through experimental results under $-32^{\circ}C$ ambient temperature.
Keywords
start-up logic; constant power; microturbine; inverter; sensorless;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 B.-H. Bae, S.-K Sui, J.-H. Kwon, and J.-S. Shin, 'Implementation of sensorless vector control for super-high speed PMSM of turbo- compressor,' IEEF/ISA Cicago Annual Meeting, 2001   DOI
2 최강모 '디젤 엔진의 냉시동(Cold Start)의 특허 동향 보고서,' 한국특허정보원, 12. 2004
3 L. Xu and C. Wang, 'Implementation and experimental investgation of sensorless control schemes for PMSM in super high variable speed operation,' IEEF/ISA, 1998   DOI
4 W. G. Scott, 'Micro-turbine generators for distribution systems,' IEEE, Industry Applications Magazine, pp. 57-62, 1998   DOI   ScienceOn
5 노민식, 박승엽, '터보 제너레이터의 시동기 제어에 관한 연구' 제어.지동화.시스템공학 논문지, 제10 권, 제3호, pp. 286-293, 3. 2004   과학기술학회마을   DOI