• Title/Summary/Keyword: Control efficiency

Search Result 9,368, Processing Time 0.04 seconds

Partial transmission block production for real efficient method of block and MLC (Partial transmission block 제작 시 real block과 MLC를 이용한 방법 중 효율적인 방법에 대한 고찰)

  • Choi JiMin;Park JuYoung;Ju SangGyu;Ahn JongHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.19-24
    • /
    • 2004
  • Introduction : The Vaginal, the urethra, the vulva and anal cancer avoid the many dose to femur head and the additional treatment is necessary in inguinal LN. The partial transmission block to use inguinal LN addition there is to a method which it treats and produce partial transmission block a method and the MLC which to it analyzes. Material & Methode : The Inguinal the LN treatment patient partial transmission it used block and the MLC in the object and with solid water phantom with the patient it reappeared the same depth. In order to analyze the error of the junction the EDR2 (Extended dose range, the Kodak and the U.S) it used the Film and it got film scanner it got the beam profile. The partial transmission block and the MLC bias characteristic, accuracy and stability of production for, it shared at hour and comparison it analyzed. Result : The partial the transmission block compares in the MLC and the block production is difficult and production hour also above 1 hours. The custom the block the place where it revises the error of the junction is a difficult problem. If use of the MLC the fabrication will be break and only the periodical calibration of the MLC it will do and it will be able to use easily. Conclusion : The Inguinal there is to LN treatment and partial transmission block and the MLC there is efficiency of each one but there is a place where the junction of block for partial transmission block the production hour is caught long and it fixes and a point where the control of the block is difficult. like this problem it transfers with the MLC and if it treats, it means the effective treatment will be possible.

  • PDF

A Study On Irrigation Water Price Structure and Prescription (농업용수의 가격구조에 관한 연구)

  • 심기영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.4
    • /
    • pp.3170-3180
    • /
    • 1973
  • This study of the subject will review past and present irrigation development in Korea. Particular attention will be given to water pricing structure and a case study on the purpose of rational operation and management of irrigation water and organizations, and the optimum irrigation water and organizations, and the optimum irrigation water fee inorder to reduce farmers burden and to rationalize the farmland associations management so as to achieve development of the rural environment. In 1971, the reservoir of the Farmland Improvement A sociation (FIA) produced only 775 millison $m^3$ of irrigation water or 77% of planned capacity of 1,015 million $m^3$. It was caused by inefficient maintenance of irrigation facilities; for instance, about 21% of reservoirs, pumping stations and weirs in Korea have been silted by soil erosion which hinder to water production according to an ADC survey. The first Irritation Association was established in 1906, whcih was renamed the Farmland Assoeiation by the Rural Development Enouragement Law in 1970. By the end of 1971, 411,000 ha of rice paddies were under the control of 267 associations nationwide. The average water price assessed by Associations nationwide rose from 790 won per 0.1 ha. in 1966 to 1,886 won in 1971. The annual growth rate was 20%. The highest water price in 1971 was 4,773 won her 0.1 ha. and the lowest was 437 won. This range was caused by differences in debt burden, geographic conditions and management efficiency among the Associations. In 1971, the number of Associations which exceeded the average water price of 1,886 won per 0.1 ha. was 144, or 55.1% of all Association. In determination of water price, there are two principles; one is determined by production cost such as installation cost of irrigation facilities, maintenance cost, management cost and depreciation ect. For instance, the Yong San River Development project was required 33.7 billion won for total construction and maintenance cost is 3.1 billion won for repayment, maintenance and management cost per year. The project produces 590 million $m^3$ of irrigation water annually. Accordingly, the water price per $m^3$ is 5.25 won. The other principle is determined by water value in the crop products and in compared with production of irrigated paddy and non-irrigated paddy. By using this method, water value in compared with paddy rice vs. upland rice(Average of 1967-1971) was 14.15 won per $m^3$ and irrigated paddy vs. non-irrigated paddy was 2.98 won per $m^3$. In contrast the irrigation fee in average association of 1967-1971 was 1.54 won per $m^3$. Accordingly, the current national average irrigation fee(water price) is resonable compared with its water value. In this study, it is found that the ceiling of water price in terms of water value is 2.98 won per $m^3$ or 2,530 won per 0.1 ha. However, in 1971 55% of the associations were above the average of nationwide irrigation fees. which shows the need for rationalization of the Association's management. In connection with rationalization of the Association's management, this study recommends the following matters. (1) Irrigation fee must be assessed according to the amount of water consumption taking intoaccount the farmer's ability. (2) Irrigation fee should be graded according to behefits and crop patterns. (3) Training personnel in the operation and procedures of water management to save O&M costs. (4) Insolvent farmland association should be integrated into larger, sound associations in the same GUN in order to reduce farmers' water cost. (5) The maintenance and repair of existing irrigation facilities is as important as expansion of facilities. (6) Establishment of a new Union of Farmland Association is required to promoted proper maintenance and to protect the huge investment in irrigation facilities by means of technical supervision and guidance.

  • PDF

Analyses of User Behavior and Preference Factors in the Outdoor Spaces of Psychiatric Hospitals (정신병원 옥외공간의 이용행태 및 선호요인 분석)

  • Ahn, Deug-Soo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.6
    • /
    • pp.72-88
    • /
    • 2014
  • This study was conducted in order to analyze user behavior and preference factors in the outdoor spaces of mental hospitals. Among hospitals with 250 or more beds, 5 hospitals were selected in consideration of size of garden and diversity of garden elements. The subject of the study was restricted to mild cases of schizophrenia while 30~50 patients were selected on the recommendation of their doctor from 5 hospitals, respectively. The physical environment was analyzed, focusing on space components, after visiting the sites of study. A face to face interview method was selected in consideration of patients' cognitive abilities, a total of 230 questionnaires were used for the analysis. The results of the study can be summarized as follows. Rest facilities occupy the largest numbers in the components of garden, and those are followed by landscape facilities, walking/exercise facilities, and experience facilities. Outdoor walking/exercise programs are classified into group walks and free walks with most patients taking group walks. Most of the patients visit these outdoor spaces every day but some of them rarely use the outdoor areas. In order to increase the efficiency of using these outdoor spaces, the percentage of space for ensuring a sense of control should properly harmonize with the percentage of space to facilitate patients in having social contact. With regard to the reasons for preferring the most widely-used outdoor spaces, landscape/environment property was the most important, followed by functionality and then accessibility. Major activities in the preferred space are mainly composed of walking/exercise and rest. The preferred facilities are waterscape facilities such as ponds, waterfalls and fountains, rest facilities such as pergolas and shade trees, and lawn. It was understood that naturalness should be considered to be the most important factor in constructing a new healing garden, followed by aesthetics and amenities. Single facilities rated by preference for introduction were flower beds, trails, and lawn. According to type, waterscape facilities such as fountains, ponds, waterfalls and waterwheels were most preferred. Space for natural distraction and programs for the cultivation of flower beds were also preferred. The ideal image of a healing garden should be bright, familiar, and orderly as a whole, having plenty of introduced facilities. Open spaces were preferred to enclosed spaces. Finally, the image of a garden that helps patients feel calm was thought to be that of the most ideal garden.

A Feasibility Study on the Deep Soil Mixing Barrier to Control Contaminated Groundwater (오염지하수의 확산방지를 위한 대체 혼합차수재의 적용에 관한 연구)

  • 김윤희;임동희;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.53-59
    • /
    • 2001
  • There is a lot of method to manage the insanitary landfill but vertical cutoff walls have been widespreadly used and were installed into the subsurface to act as a barrier to horizontal groundwater flow, The stabilized material such as specialized cement or mixed soil with additives has been generally applied for the materials of the deep soil mixing barrier in korea. The amount of the stabilized material is dependent on the field conditions, because the mixing ratio of the material and the field soil should achieve a requirement in the coefficient of permeability, lower than 1.0$\times$$10^{7}$cm/sec. This study determined the quantity and optimized function ratio of the stabilized material in the formation process of the mixed barrier that was added with stabilized material on the field soil classified into SW-SC under USCS (Unified Soil Classification System). After that the fly ash and lime were selected as an additives an that could improve the function of the stabilized material and then the method to improve the functional progress in the usage of putting into the stabilized material as an appropriate ratio was studied and reviewed. The author used the flexible-wall permeameter for measuring the permeability and unconfined compressive strength tester for compressive strength, and in the view of environmental engineering the absorption test of heavy metals and leaching test regulated by Korean Waste Management Act were performed. As the results, the suitable mixing ratio of the stabilized material in the deep soil mixing barrier was determined as 13 percent. To make workability easy, the ratio of stabilized material and water was proven to be 1 : 1.5. With the results, the range of the portion of the additives(fly ash : lime= 70 : 30) was proven to be 20-40% for improving the function of the stabilized material, lowering of permeability. In heavy metal absorption assessment of the mixing barrier system with the additives, the result of heavy metal absorption was proved to be almost same with the case of the original stabilized material; high removal efficiency of heavy metals. In addition, the leaching concentration of heavy metals from the leaching test for the environmental hazard assessment showed lower than the regulated criteria.

  • PDF

Decrease of Aflatoxin M1 Level in Raw Cow’s Milk using the Hazard Analysis and Critical Control Points (HACCP) System (HACCP 제도에 의한 우유의 아플라톡신 M1의 저감화)

  • Kim, Ki-Hwan;Nam, Myoung Soo
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.190-197
    • /
    • 2016
  • Aflatoxin M1 can be produced in cow’s milk when cows eat contaminated produce. Milk is a major source of food for infants and for children who have a weak level of immunity, and the detection of Aflatoxin M1 for risk assessment is necessary in order to reduce the amount of it in milk. In this study, the Aflatoxin M1 level was monitored for one year in raw milk samples obtained from Chungnam Province, Korea. The milk samples were divided into three categories: 1. milk samples from a standard general farm, 2. milk samples from a HACCP controlled farm, and 3. milk samples from the supply of Aflatoxin M1 reduced fodder. The average concentrations of Aflatoxin M1 in milk were 0.023±0.005 ug/l for the standard general farm, 0.017±0.004 ug/l for the HACCP controlled farm, and 0.013±0.003 ug/l for the supply of Aflatoxin M1 reduction fodder. Milk collected from the supply of Aflatoxin M1 reduction fodder had the lowest level of Aflatoxin M1. However, when efficiency and economic aspects are considered the most effective way of reducting Aflatoxin M1, could be taking milk from the HACCP controlled farm and implementing good feed management. Institutional support from the government, careful management of dairy farming, and a strict farm sanitation program are required in order to lower the level of Aflatoxin M1 in milk.

Presence of Leukemia-maintaining Cells in Differentiation-resistant Fraction of K562 Chronic Myelogenous Leukemia (만성 골수성 백혈병 K562세포의 분화 내성 분획에서 백혈병 유지 세포의 동정)

  • Lee, Hong-Rae;Kim, Mi-Ju;Ha, Gahee;Kim, So-Jung;Kim, Sun-Hee;Kang, Chi-Dug
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.197-206
    • /
    • 2013
  • The present study investigated whether leukemia-maintaining cells reside in a differentiation-resistant fraction using a megakaryocytic differentiation model of K562 cells. Treatment with phorbol-12-myristate-13-acetate (PMA) significantly inhibited the colony-forming efficiency of the K562 cells. At a PMA concentration of 1 nM or higher, colony was not formed, but approximately 40% of K562 cells still survived in soft agar. Approximately 70% of colony-forming cells that were isolated following the removal of PMA after exposure to the agent were differentiated after treatment with 10 nM PMA for 3 days. The differentiation rate of the colony-forming cells was gradually increased and reached about 90% 6 weeks after colony isolation, which was comparable to the level of a PMA-treated K562 control. Meanwhile, imatinib-resistant variants from the K562 cells, including K562/R1, K562/R2, and K562/R3 cells, did not show any colony-forming activity, and most imatinib-resistant variants were CD44 positive. After 4 months of culture in drug-free medium, the surface level of CD44 was decreased in comparison with primary imatinib-resistant variants, and a few colonies were formed from K562/R3 cells. In these cells, Bcr-Abl, which was lost in the imatinib-resistant variants, was re-expressed, and the original phenotypes of the K562 cells were partially recovered. These results suggest that leukemia-maintaining cells might reside in a differentiation-resistant population. Differentiation therapy to eliminate leukemia-maintaining cells could be a successful treatment for leukemia if the leukemia-maintaining cells were exposed to a differentiation inducer for a long time and at a high dose.

Migration of $^{99m}Tc$-Hexamethylpropylene Amino Oxime (HMPAO) Labeled Immature and Mature Dendritic Cells in the Mouse (마우스에서 Tc-99m HMPAO 표지 미성숙 및 성숙 수지상세포의 이동에 관한 연구)

  • Li, Ming-Hao;Lee, Je-Jung;Min, Jung-Joon;Heo, Young-Jun;Song, Ho-Chun;Park, Young-Kyu;Park, An-Na;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.26-33
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate migration of technetium-99m hexamethylpropylene amine oxime ($^{99m}Tc$-HMPAO) labeled immature and mature dendritic cells (DC) in the mouse. Methods: DC were collected from bone marrow (BM) of tibiae and femurs of mice. Immature and mature DC from BM cells were radiolabeled with $^{99m}Tc$-HMPAO. To evaluate the functional and phenotypic changes of DC from radiolabeling, the allogeneic mixed lymphocyte reaction (MLR) and fluorescence-activated cell sorting (FACS) analysis were performed before and after labeling with $^{99m}Tc$-HMPAO. Migration of intravenously injected DC (iv-DC) was assessed by serial gamma camera images of mice with or without subcutaneous tumor. Percent injected dose per gram (%ID/g) was calculated in lungs, liver, spleen, kidneys, and tumor through dissection of each mice after 24 hours of injection. Results: Labeling efficiency of immature and mature DC were $60.4{\pm}5.4%\;and\;61.8{\pm}6.7%$, respectively. Iv-DC initially appeared in the lungs, then redistributed mainly to liver and spleen. Migration of mature DC to spleen was significantly higher than that of immature DC ($38.3{\pm}4.0%\;vs.\;32.2{\pm}4.1%$ in control group, $40.4{\pm}4.1%\;vs.\;35.9{\pm}3.8%$ in tumor group; p<0.05). Migration to tumor was also significantly higher in mature DC than in immature DC ($2.4{\pm}0.3%\;vs\;1.7{\pm}0.2%$; p=0.034). Conclusion: Assessment of migration pattern of DC in mice was possible using $^{99m}Tc$-HMPAO labeled immature and mature DC. Migration of mature DC to spleen and tumor was higher than that of immature DC when they were i.v. injected.

Environment-friendly and Low-Carbon Agriculture for Demand-Supply Control and Food Security of Korean Rice (쌀 수급안정과 식량안보를 위한 친환경·저탄소 농업 전환방안)

  • Yang, Seung-Koo;Park, Pyung-Sik;Son, Jang-Hwan;An, Kyu-Nam
    • Korean Journal of Organic Agriculture
    • /
    • v.26 no.1
    • /
    • pp.99-128
    • /
    • 2018
  • The cultivation area of rice as staple grains is decreasing in the domestic situation in Korea. Import volume of a duty in foreign rice is 409,000 tons for a year regardless increasing of production per unit area and decreasing of rice consumption. The total stock of rice is increasing cumulatively despite the effort for production mediation of rice. Therefore, maintenance of cultivation area and reduction of production are necessary for national foodstuffs security problems. Development of environment-friendly and low-carbon technology as alternative of global warming and aging of farm labor power is very important responsibility for descendants with creation of sustainable agriculture environment. As alternative for demand and supply stabilization of rice from all angles, first stage: extension of environment-friendly cultivation area as 17% Jeollanam-do level with maintenance of cultivation area under the present circumstances, second stage: extension of environment-friendly cultivation area as 25%, third stage: extension of environment-friendly cultivation area as 35%. From above mentioned scenario, reduction of rice production (60,000 tons), increases of production cost (59,200,000,000 Won), and reduction of income (201,500,000,000 Won) are estimated in first stage. Reduction of rice production (90,000 tons), increases of production cost (122,100,000,000 Won), and reduction of income (313,700,000,000 Won) are estimated in second stage. Reduction of rice production (380,000 tons), increases of production cost (222,000,000,000 Won), and reduction of income (464,500,000,000 Won) are estimated in third stage. From analysis results for partial tillage in transplanting cultivation complex (10ha), rice production is decreased 1.3~1.5 ton by complex. Production cost of rice is decreased and increases of income cultivation type. Gradual extension of environment-friendly agriculture and low-carbon partial tillage could be expected for environment maintenance of the territorial integrity, confidence of consumer, and high-efficiency of low-cost.

Analysis and Design of Profiling Adaptor for XML based Energy Storage System (XML 기반의 에너지 저장용 프로파일 어댑터 분석 및 설계)

  • Woo, Yongje;Park, Jaehong;Kang, Mingoo;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.29-38
    • /
    • 2015
  • The Energy Storage System stores electricity for later use. This system can store electricity from legacy electric power systems or renewable energy systems into a battery device when demand is low. When there is high electricity demand, it uses the electricity previously stored and enables efficient energy usage and stable operation of the electric power system. It increases the energy usage efficiency, stabilizes the power supply system, and increases the utilization of renewable energy. The recent increase in the global interest for efficient energy consumption has increased the need for an energy storage system that can satisfy both the consumers' demand for stable power supply and the suppliers' demand for power demand normalization. In general, an energy storage system consists of a Power Conditioning System, a Battery Management System, a battery cell and peripheral devices. The specifications of the subsystems that form the energy storage system are manufacturer dependent. Since the core component interfaces are not standardized, there are difficulties in forming and operating the energy storage system. In this paper, the design of the profile structure for energy storage system and realization of private profiling system for energy storage system is presented. The profiling system accommodates diverse component settings that are manufacturer dependent and information needed for effective operation. The settings and operation information of various PCSs, BMSs, battery cells, and other peripheral device are analyzed to define profile specification and structure. A profile adapter software that can be applied to energy storage system is designed and implemented. The profiles for energy storage system generated by the profile authoring tool consist of a settings profile and operation profile. Setting profile consists of configuration information for energy device what composes energy saving system. To be more specific, setting profile has three parts of category as information for electric control module, sub system, and interface for communication between electric devices. Operation profile includes information in relation to the method in which controls Energy Storage system. The profiles are based on standard XML specification to accommodate future extensions. The profile system has been verified by applying it to an energy storage system and testing charge and discharge operations.

Study on Ventilation Efficiency of A Naturally Ventilated Broiler House-( I ) Summer Season (자연환기식 육계사내의 환기효율성 조사연구-( I )하절기)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;성시흥
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • Most of broiler houses in Korea have the trouble of environmental control such as suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens. Accordingly, it is very urgent to develop optimum designs of naturally and mechanically ventilated broiler houses for Korean climate. In this study, the internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were measured at a naturally ventilated broiler house. The data were collected during summer season including local weather data. It was found that the difference between measured and optimum air temperatures was $14.0^{\circ}C$ in maximum during the summer time. The daily maximum range of internal averaged air temperature was found $10.5^{\circ}C$ while the uniformity was $5.2^{\circ}C$ in maximum. The maximum, average, and minimum internal averaged relative humidity were 89.3%, 73.7%, and 49.2%, respectively while locally measured were 95.1% and 47.2%, respectively in maximum and minimum. Considering Temperature-humidity index, during summer season, over 97% of totally rearing period was shown that counter plan is needed for thermal stress while it was very dangerous situation for 22% of the rearing period. The ammonia gas and dust concentrations were seriously affected by the broilers activity, growth level, and relative humidity.

  • PDF