• 제목/요약/키워드: Control circuit

Search Result 3,859, Processing Time 0.03 seconds

In Memristor Based Differential or Integral Control Circuit, Hysteresis Curve Characteristic Analysis According to Capacitance (멤리스터 기반 미분 및 적분제어 회로에서의 커패시턴스 변화에 따른 히스테리시스 곡선 특성 분석)

  • Choi, Jin-Woong;Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.10
    • /
    • pp.658-664
    • /
    • 2015
  • This paper presents an electrical feature analysis of hysteresis curves in memristor differential and intergral control circuit. After making macro model of the memristor device, electric characteristics of the model such as time analysis, frequency dependent DC I-V curves were performed by PSPICE simulation. Also, we made a circuit of memristor-capacitor based on nano-wired memristor device and analyzed the simulated PSPICE results. Finally, we proposed a memristor based differential or integral control circuit, analyzed hysteresis curve characteristic in the control circuit.

Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply (보조전원장치의 단락부하 차단기 개방을 위한 제어방법)

  • 황광철;조국춘;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

Implementation of ELB Leakage Current Control System based on ZigBee Communication (ZigBee통신 기반 ELB 누전전류 제어시스템 구현)

  • Ju, Jae-Han
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.52-57
    • /
    • 2012
  • Social development as well as the development of consumer electronic devices due to leakage, electric shock or fire, and many are exposed to the risk of leakage currents. Premises in the control cabinet, but the circuit breaker is installed, the existing circuit breaker shuts off when a short circuit in the control cabinet, installed only have the capability. Also connected to the outlet is installed byeokmada family of devices is not easy thing to check individually. In this paper, circuit breakers and circuit analysis and circuit performance, ZigBee-based premises of consumer electronics devices using sensors to monitor the health of the leakage can be presented on how. Performance analysis, the proposed ELB leakage current control system is built into the appliance leakage circuit breaker for each household appliances because the application can check the status of a short circuit, short circuit, over the existing system can be monitored easily.

Characterics of Meter-In / Meter-Out Circuits to pneumatic System (공압회로에서 미터인 회로와 미터아웃 회로의 특성 비교)

  • 박재범;염만오
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.446-450
    • /
    • 2002
  • Pneumatic system has been mainly used as main equipment for actuation and control of compressed air force in manufacturing industry, pneumatic circuit for the most part is used in Meter-Out circuit. Meter-Out circuit method is Flow Control Valve to fit in exhaust part of cylinder port. In the reverse, Meter-In circuit is Flow Control Valve to fit in input part of cylinder port. This study examines the dynamic characteristics comparison of Meter-In and Meter-Out Circuits in the pneumatic circuits. The results of the experimental research are obtained to the followings: i ) System Response is Meter-In Circuit more than Meter-Out one before cushion zone. ii) we conjectured that the collision of piston and head cover is ease to collide Meter-In Circuit more than Meter-Out one at the stroke end part.

  • PDF

A New Power Factor Correction Circuit Using Boost Converter (부스트 컨버터를 이용한 새로운 역율 개선회로)

  • 김만고
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.178-185
    • /
    • 1997
  • According to the wide - spread use of rectifier in electronic equipments, such problems as electronic components failures or equipment disorders have been occurred due to current harmonics. To overcome these problems, power factor correction circuits employing boost converter have been used. The high switching stress of boost converter can be reduced by snubber circuit. Recently, research activities in snubber circuits have been directed to energy recovery snubber for improving the efficiency of power converter. In this study, a new passive snubber circuit which can recover trapped snubber energy without added control is proposed for boost converter. The control of boost converter with proposed snubber is the same as the conventional one. In addition, the energy recovery circuit can be implemented with a few passive components. The circuit operation is confirmed through simulation.

  • PDF

Design methodology of the controller circuit for a highly efficient class D Amplifiers (D급 증폭기를 위한 제어회로의 설계)

  • Lee, Jong-Kue;Song, Pil-Jae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.407-409
    • /
    • 2006
  • This paper presents the methods of designing the control circuits for a Class D amplifier to have a peak performance. The proposed approach is based on the three functional components - a carrier generator, a feedback circuit and a dead-time circuit. First the analog signal is applied to the controller, which outputs the 3 level PWM waveform. The controller used for this experiment is made of the operational amplifier and the logic circuit. The experimental results show that the control circuit performs with satisfaction and its output is proportional to input audio signal, providing a satisfactory 3 level PWM pattern. From this design methodology, by implementing a proposed control circuit we can achieve the efficient Class D amplifier using the half-bridge, full-bridge or push-pull topology at the output stage.

  • PDF

A Study on the Control Method of Hand & Automatic Operation of On-Off Wiring of an Easy Elevator (간이 엘리베이터 수.자동 개폐배선 제어방식에 관한연구)

  • Wee, Sung-Dong;Gu, Hal-Bon;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1107-1112
    • /
    • 2002
  • An easy elevator originated is an opened system to compare an existing equipment, and learning efficient is high as a wiring that the sequence control circuit is on and off. The structure of an equipment to be controled from the first floor to the fifth floor is constructed by a lamp to express the function of the open-close of the door according to the cage moving, to express the mechanical actuation of the forward-reverse break and motor of load and of hand-worked control component of Push-Button S/W, L/S and Relay. In order to act of the elevator function that these components connected, designed the auto program and the sequence control circuit. Consequently the process that these(1~5steps) operated the cage with an auto program of the elevator and the sequence control circuit is controled by the step of forward and reverse that the L/S1~L/S5 of sensor adjust function let posit, by the adjustable S/W1~S/W5 of PLC testing panel and the S/W1~S/W5 which installed on the transparent acryl plate of a frame. In here, improved apparatus is the learning equipment of combined use to study the principle and the technique of the originated sequence control circuit and the auto program of PLC.

  • PDF

Levitation Control Circuit Design for a Magnetic Levitation System Supplied with a Battery (배터리로 구동되는 자기부상시스템의 부상제어회로 설계)

  • Nam, Yun-Ho;Park, Seung-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.27-29
    • /
    • 2004
  • In this paper, a levitation control circuit for a magnetic levitation system supplied with a battery is designed. The control circuit consists of DSP, 4-quadrant chopper, and gap sensor as feedback sensors. Moreover the DSP includes PWM generator, A/D converter, etc. The feedback signals from gap sensors go into A/D converter of DSP to compare with reference. As a result, The design procedures of the levitation control circuit and battery power distribution system are described and basic experiment results are shown.

  • PDF

Feedback Loudness Control Circuit (피이드백 라우드니스 제어회로)

  • Kim, Ju-Hong;Sim, Gwang-Bo;Eom, Gi-Hwan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.6
    • /
    • pp.58-61
    • /
    • 1983
  • This is a Loudness Control Circuit in an audio amplifier controlled by feedback type volume control variable resistors. This circuit consists of Bridged Twin T network and a ordinary variable resistor. The variably resistor acts not only as a volume control by varying feedback qupntity, but also as Loudness Control through the characteristics variation by Sound Level. This new Loudness Control Circuit showed ideal compensation characteristics that agree computer simulation and measured datas.

  • PDF

A Study on the wiring Control Method of Hand & Auto Operation of an easy Elevator (간이 승강기 수.자동 배선제어방식에 관한 연구)

  • Wee, Sung-Dong;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.596-602
    • /
    • 2002
  • An easy elevator for learning originated is opened to compare the existed learning equipment, and it had a high studying efficient that the sequence control circuit can opens and closes with the wire. The structure of equipment to be controlled from the first floor to the fifth floors is demonstrated a constructive apparatus by a lamp atc to express the function of the open-close of the door according to the cage moving with a mechanical actuation of the forward-reverse breaker and the motor of load and a mechanical actuation of hand-operation control components of push-button S/W and L/S and relay etc. These components let connects each other in order to control of the elevator function with the auto program and the designed sequence control circuit. Consequent1y the process of these functions of 1~5steps could operates the cage with an auto program of the elevator and the sequence control circuit. The sequence control circuit is controlled by the step of forward and reverse to follow as that the sensor function of the L/S1~L/S5 let posit with the control switchs of S/W1~S/W5 of PLC testing panel and switchs of S/W1~S/W5 installed on the transparent acryl plate of the frame. In here, improved apparatus is a hand-auto operation combined learning equipment to study the principle and a technique of the originated sequence control circuit and the auto program of PLC.

  • PDF