• 제목/요약/키워드: Control circuit

검색결과 3,859건 처리시간 0.03초

카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계 (Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit)

  • 이성래
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

승강기의 비상 통화장치용 비상 전원장치의 충·방전 제어회로 (Control Scheme of Emergency Power Supply for Elevator Emergency Call System)

  • 박노식;이동희
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.40-48
    • /
    • 2015
  • In this paper, battery charging and discharging circuit with a single voltage power supply is proposed. The proposed circuit has the separated current path and charging-monitoring sequence control scheme. In the charging sequence, the proposed 2-level comparator combined with control signal of the micro-processor can control the constant charging current to protect the over current of the battery. Furthermore, the proposed circuit uses a periodic main power switch control to detect the discharging characteristics to estimate the approximated battery life-time. In the experiments, the proposed emergency power supply for emergency call system has 89% efficiency with 98% power factor. And the proposed sequence control scheme is well operated in the designed emergency power system.

광역 주파수 전류원형 인버터 (Wide Frequency Current Source Inverter)

  • 전성즙;조규형
    • 대한전기학회논문지
    • /
    • 제43권6호
    • /
    • pp.927-935
    • /
    • 1994
  • Detailed analysis of the commutation circuit of the proposed wide-frequency current source inverter is given. In this inverter a spike-limit circuit and a precommutation circuit are used. The spike-limit circuit is intended to limit spike voltage which is arising during commutation time in a current source inverter, and the precommutation circuit to reuse the energy which flows from main inverter to spike-limit circuit during commutation time to aid commutation. Thus voltage stress of main thyristor is minimized. Since this inverter can be made up of thyristors for phase control, it has some advantage in high voltage and high power application.

Low Noise and High Linearity GaAs LNA MMIC with Novel Active Bias Circuit for LTE Applications

  • Ryu, Keun-Kwan;Kim, Yong-Hwan;Kim, Sung-Chan
    • Journal of information and communication convergence engineering
    • /
    • 제15권2호
    • /
    • pp.112-116
    • /
    • 2017
  • In this work, we demonstrated a low noise and high linearity low noise amplifier (LNA) monolithic microwave integrated circuit (MMIC) with novel active bias circuit for LTE applications. The device technology used in this work relies on a process involving a $0.25-{\mu}m$ GaAs pseudomorphic high electron mobility transistor (PHEMT). The LNA MMIC with a novel active bias circuit has a small signal gain of $19.7{\pm}1.5dB$ and output third order intercept point (OIP3) of 38-39 dBm in the frequency range 1.75-2.65 GHz. The noise figure (NF) is less than 0.58 dB over the full bandwidth. Compared with the characteristics of the LNA MMIC without using the novel active bias circuit, the OIP3 is improved about 2-3 dBm. The small signal gain and NF showed no significant change after using the active bias circuit. The novel active bias circuit indeed improves the linearity performance of the LNA MMIC without degradation.

PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술 (Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device)

  • 김용중;나재호;김효성
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

A Low Distortion and Low Dissipation Power Amplifier with Gate Bias Control Circuit for Digital/Analog Dual-Mode Cellular Phones

  • Maeng, Sung-Jae;Lee, Chang-Seok;Youn, Kwang-Jun;Kim, Hae-Cheon;Mun, Jae-Kyung;Lee, Jae-Jin;Pyun, Kwang-Eui
    • ETRI Journal
    • /
    • 제19권2호
    • /
    • pp.35-47
    • /
    • 1997
  • A power amplifier operating at 3.3 V has been developed for CDMA/AMPS dual-mode cellular phones. It consists of linear GaAs power MESFET's, a new gate bias control circuit, and an output matching circuit which prevents the drain terminal of the second MESF from generating the harmonics. The relationship between the intermodulation distortion and the spectral regrowth of the power amplifier has been investigated with gate bias by using the two-tone test method and the adjacent channel leakage power ratio (ACPR) method of CDMA signals. The dissipation power of the power amplifier with a gate bias control circuit is minimized to below 1000 mW in the range of the low power levels while satisfying the ACPR of less than -26 dBc for CDMA mode. The ACPR of the power amplifier is measured to be -33 dBc at a high output power of 26 dBm.

  • PDF

정태회로해석에 의한 전력부하로서의 유도전동기 시뮬레이션 및 파라메터 식별 (Simulation and Parameter Identification of Induction Machine in Load Modeling based on the Static Circuit Analysis)

  • 이봉용;심건보;고태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.370-374
    • /
    • 1991
  • This paper presents a static circuit model for static ant dynamic simulation of induction motors and identification of motor parameters. Instead of usual T-circuits, equivalent ${\pi}$-circuit has been proposed so that power Inputs into motor terminals can very easily calculated with very well known load flow method. It has been shown that, with wide range variation of applied voltage and frequency, successful static simulations can be performed and further the proposed static model can be used to simulate dynamic characteristics. Finally it is shown also that motor parameters can easily be identified based on the proposed static circuit.

  • PDF

전압제어 회로에 의한 호이스트용 통합 드라이브 장치 (The Integration Drive Equipment for Hoistby using Voltage Control Circuit)

  • 라병훈;송대현;서기영;고희석;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.281-286
    • /
    • 2002
  • An existent hoist drive system is using each different drive equipment in control of Hoisting, traveling(T/L), traversing(T/S) driving, so there are much energy losses because of excessive weight. Also, power circuits are using relay contact, so working environment are frequent secession accident etc.. by shock on unfavorable condition, and there is danger of safety accident, maintenance has frequent problem and so on. To solve these problem, it is integrated each driving power supply in drive system for hoist control and drive, utility power supply etc.. by single device in this research. The power circuit is consisted of non-contact circuit applying to bidirectional voltage controller circuit using thyristor that is power semiconductor switching device

  • PDF

사이리스터 디지털 점호제어 (Digital Firing Control for Thyristor Converter)

  • 김장목
    • 전력전자학회논문지
    • /
    • 제9권6호
    • /
    • pp.584-591
    • /
    • 2004
  • 기존의 아날로그 점호각 제어방법은 op-amp, 저항 및 커패시터 등을 사용하였기 때문에 아날로그 회로의 특성상 온도와 소자의 경년변화에 따라 파라메타 값이 변동하며 전원전압의 노이즈에 민감하게 반응하는 단점이 있었다. 따라서 본 논문에서는 디지털 사이리스터 점호회로를 이용하여 기존의 아날로그 점호회로 장점인 선형특성, 그리고 전원전압 노이즈 온도 및 갱년변화에 의한 수동소자의 변동에 강인한 특징을 갖는다. 또한 디지털 시스템의 장점인 연산기능을 이용하여 전원전압의 불평형 발생시 디지털 시스템의 특징인 연산기능을 이용하여 전원전압의 불평형을 검지하고 보상알고리즘을 도입하여 언제나 리플이 없는 출력전압을 만들어내어 사이리스터 전력변환 시스템의 안정적인 운전이 가능하게 할 수 있는 장점이 있다.

전지관리장치(BMS)의 서지내성 성능향상 기법 (Surge Immunity Performance Enhancement Techniques on Battery Management System)

  • 김용성;임성정;서우현;정중일
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.