• Title/Summary/Keyword: Control System Box

Search Result 323, Processing Time 0.025 seconds

An intelligent eddy current signal evaluation system to automate the non-destructive testing of steam generator tubes in nuclear power plant

  • Kang, Soon-Ju;Ryu, Chan-Ho;Choi, In-Seon;Kim, Young-Ill;Kim, kill-Yoo;Hur, Young-Hwan;Choi, Seong-Soo;Choi, Baeng-Jae;Woo, Hee-Gon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.74-78
    • /
    • 1992
  • This paper describes an intelligent system to automatic evaluation of eddy current(EC) signal for Inspection of steam generator(SG) tubes in nuclear power plant. Some features of the intelligent system design in the proposed system are : (1) separation of representation scheme ,or event capturing knowledge in EC signal and for structural inspection knowledge in SG tubes inspection; (2) each representation scheme is implemented in different methods, one is syntactic pattern grammar and the other is rule based production. This intelligent system also includes an data base system and an user interface system to support integration of the hybrid knowledge processing methods. The intelligent system based on the proposed concept is useful in simplifying the knowledge elicitation process of the rule based production system, and in increasing the performance in real time signal inspection application.

  • PDF

BOXES-based Cooperative Fuzzy Control for Cartpole System

  • Kwon, Sung-Gyu
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.7 no.1
    • /
    • pp.22-29
    • /
    • 2007
  • Two fuzzy controllers defined by 2 input variables cooperate to control a cartpole system in terms of balancing as well as centering. The cooperation is due to the BOXES scheme that selects one of the fuzzy controllers for each time step according to the content of box that is established through the critic of the control action by the fuzzy controllers. It is found that the control scheme is good at controlling the cartpole system so that the system is stabilized fast while the BOXES develops its ability to select proper fuzzy controller through experience.

Design of Heat Pump for Temperature Control of Sealed Electric Box (밀폐 형 전장 박스 온도 제어를 위한 히트 펌프 설계)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.110-114
    • /
    • 2020
  • In this paper, a heat pump using a Peltier device was developed for heat dissipation in a sealed electric box. The heat pump was designed with a cooling fin attached to both sides of the Peltier device, and a fan was mounted on the cooling fin on the hot side to increase the efficiency. The heat dissipation efficiency could be improved by directly connecting the electronic component having high heat to the cooling fin using a heat conducting wire. The fabricated heat pump was designed to operate only in the temperature range set by the temperature control system to improve the problem of high power consumption of the Peltier element.

Building Control Box Attached Monitor based Color Grid Recognition Methods for User Access Authentication

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Khudaybergenov, Timur;Kim, Min Soo;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • The secure access the lighting, Heating, ventilation, and air conditioning (HVAC), fire safety, and security control boxes of building facilities is the primary objective of future smart buildings. This paper proposes an authorized user access to the electrical, lighting, fire safety, and security control boxes in the smart building, by using color grid coded optical camera communication (OCC) with face recognition Technologies. The existing CCTV subsystem can be used as the face recognition security subsystem for the proposed approach. At the same time a smart device attached camera can used as an OCC receiver of color grid code for user access authentication data sent by the control boxes to proceed authorization. This proposed approach allows increasing an authorization control reliability and highly secured authentication on accessing building facility infrastructure. The result of color grid code sequence received by the unauthorized person and his face identification allows getting good results in security and gaining effectiveness of accessing building facility infrastructure. The proposed concept uses the encoded user access authentication information through control box monitor and the smart device application which detect and decode the color grid coded informations combinations and then send user through the smart building network to building management system for authentication verification in combination with the facial features that gives a high protection level. The proposed concept is implemented on testbed model and experiment results verified for the secured user authentication in real-time.

Implementation of Digital Twin based Building Control System using Wireless Sensor Box

  • Shin, Sang-Hoon;Park, Myeong-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.57-64
    • /
    • 2020
  • In this paper, based on the building's 3D modeling, a digital twin-based building control system using the collection information of wireless sensor box is proposed. The proposed system applies wireless sensors, making sensor modules more expandable and usable, and more intuitive building control possible through three-dimensional modeling. In addition, effective control and visual representation are possible through BIM data. Sensor boxes have been designed for general purpose so that a variety of sensor modules can be added and have been implemented for actual university buildings to demonstrate high availability. The results of this paper could be used to implement a digital twin control platform in the future.

Cooling Efficiency and Growth of Tomato as Affected by Root Zone Cooling Methods in Summer Season (고온기 근권냉방방식에 따른 냉방효과와 토마토 생육)

  • 이재한;권준국;권오근;최영하;박동금
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.81-87
    • /
    • 2002
  • This study was conducted to investigate the cooling efficiency and growth of tomatoes by root zone cooling device using a pad-box and cultivated system. The structure of the root zone cooling system using a pad-box was four piece of pads bonded an the side and a fan set at the bottom. Cool wind was generated by the outside air which was punched at intervals of 10 cm along three rows. Cold wind flowed to the root zone in the culture medium. The root zone cooling efficiency of cold wind generation by using a pad-box flowing through a wet-pad was determined. Major characteristic of this cuttural system consist of bed filled with a perlite medium and a ventilation pipe using PVC. The cold wind generation by a pad box (CWP) was compared to that of cold wind generation by a radiator (CWR), cold water circulation using a XL-pipe (CWX) and the control (non-cooling). When the temperature of water supplied was 16.2-18.4$^{\circ}C$, temperatures in the medium were 20.5~23.2$^{\circ}C$ for CWP 22.7~24.2$^{\circ}C$ for CWR, 22.8~24.27$^{\circ}C$ for CWX and 23.1~-29.6$^{\circ}C$ for the control. The results show that the cold wind temperature using the pad-box was lower by 1~2$^{\circ}C$ than that of cold water circulation in the XL-pipe and lower by 5~6$^{\circ}C$ than that of the control. Growth such as leaf length, leaf width, fresh weight and dry weight, was greater in three root zone cooling methods than in the control. Root activity was higher in the rat zone cooling methods than in the control. However, there was no significant difference among root zone cooling methods.

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..

The Realization of the Wireless Internet DGPS for LBS (LBS를 위한 무선 인터넷 DGPS 구현)

  • Kang, Joon-Mook;Cho, Sung-Ho;Lee, Eun-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.1
    • /
    • pp.3-12
    • /
    • 2008
  • This research is to construct wireless internet DGPS using MS Visual Basic Active X control for LBS. The coordinate correction method was used in this system because of convenience of both direction communication on Web. The PictureBox control and bitblt function were used in coordinate display module. The MS Comm control, MS Winsock control (TCP/IP), MS CommonDialog control, MS Sysinfo control were used in internet DGPS communication module and published on Web. Realtime internet DGPS were tested using the system which developed in this study and near realtime monitoring through this system could be performed.

  • PDF

A discrete iterative learning control method with application to electric servo motor control

  • Park, Hee-J.;Cho, Hyung-S.;Oh, Sang-R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1387-1392
    • /
    • 1990
  • In this paper, an iterative learning control algorithm for unknown linear discrete systems is proposed by employing a parameter estimator together with an inverse system model. Regardless of initial error and inherent parameter uncertainty, a good tracking control performance is obtained using the proposed learning control algorithm characterized by recursive operations. A sufficient condition for convergency is provided to show the effectiveness of the proposed algorithm. To investigate the performance of the algorithm a series of simulations and experiments were performed for the tracking control of a servo motor.

  • PDF

Sensitivity Analysis of Control Charts with Autocorrelated Data (자기상관자료를 갖는 관리도의 민감도 분석)

  • 조영찬;송서일
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.51
    • /
    • pp.1-10
    • /
    • 1999
  • In recent industry society, it is revealed that, as an increase in the use of automated manufacturing and process inspection technology, the data from mass production system exhibits some degrees of autocorrelation. The operation characteristics of traditional control charts developed under the independence assumption are adversely affected by the presence of serial correlation. Therefore, when autocorrelated construction contacted with time-series models explain, the time-series models are the Box-Jenkins forecast models which have been proposed as the best forecasting tool which allows for partitioning of variation into result from the autocorrelation structure and variation due to unusual but assignable causes. In this paper, for the AR(1) process of Box-Jenkins forecast models, when the constant term ξ are zero and different from zero, I want to analyze the sensitivity of (equation omitted), CUSUM and EWMA control chart for forecast residuals.

  • PDF