Building of GIS Program for Controlling Oil Spill Accident (해양 유출유 사고 방제 지원 GIS 프로그램 개발)

  • Kim, Hye-Jin;Lee, Han-Jin;Lee, Moon-Jin
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.3
    • /
    • pp.58-66
    • /
    • 2006
  • Environmental Sensitivity Index Map(ESI Map) is useful information for efficient and prompt contolling of oil spill accident. Environmental sensitivity information relating to oil spill is very various, so efficient access and utilization for environmental sensitivity information at control field is required. In order to improve the efficiency of controlling accident at the field, it is necessary to building digital ESI Map and GIS program. In this study, GIS database was built to utilize environmental sensitivity information at Yeosu and Gyunggi bay. And the ESI Map program which is focused on the control job was developed. IMO/IPIECA's guide to make the ESI Map and Korea Coast Guard's guide to collect information for the control information map were referenced to capture environmental sensitivity data and build GIS database. The symbology of environmental sensitivity layers was defined and functions for supporting control job were implemented in ESI Map program. For the future works, the program in this study could be applied to ESI Map program for the whole coastal area of Korea and it could be the essential element technology in marine pollution control supporting system.

  • PDF

Pharmacodynamic evaluation of hypoglycemic effect of Damtab in healthy adult male volunteers

  • Sahu, Pratap Kumar;Pillai, KK;Saha, Nilanjan;Sharma, Manju;Najmi, AK
    • Advances in Traditional Medicine
    • /
    • v.7 no.2
    • /
    • pp.205-210
    • /
    • 2007
  • The objectives of the study were (1) To evaluate the safety and tolerability of Damtab. (2) To characterize hypoglycemic effect of Damtab, if any. (3) To evaluate insulin sensitivity effect of Damtab, if any. Hypoglycemic effect of Damtab (700 mg and 1,400 mg) were examined. Gliclazide (80 mg) was used as an active control. Placebo was used as control. Breakfast was given, half an hour before dosing whereas lunch, snacks and dinner were given at 6, 10 and 14 h post dose. An oral glucose tolerance test was conducted to calculate the insulin sensitivity index from the values of glucose and insulin during oral glucose tolerance test. Both giclazide 80 mg and Damtab 1,400 mg significantly lowered plasma glucose level up to 6 h. Insulin sensitivity index of Damtab (1,400 mg) was found to be similar to that of placebo. A significant increase in insulin level at 1 h post dose of Damtab (1,400 mg) was observed. Damtab 700 mg shows placebo like effect whereas Damtab 1,400 mg possesses hypoglycemic effect.

Low Sensitive Optimal Steering System of Ships at Sea (저감도최적조타계의 설계에 관한 연구)

  • 이철영
    • Journal of the Korean Institute of Navigation
    • /
    • v.4 no.1
    • /
    • pp.19-30
    • /
    • 1980
  • The usual procedure for the optimal design of ship's steering system is to minimize a chosen quadratic performance index, which isdetermined from the view point of economic run. However, the optimal control synthesized in such a straightforward fashion is unsatisfactory because ship's parameters differ from their nominal values due to uncertainties and errors in measurement and/or simplifications in mathematical modelling, and/or the variation of the ship's loading condition. In an attempt to resolve this difficulty, this paper presents a method for designing a low sensitive optimal steering system in a way as to minimize not only given performance index but also the sensitivity of the performance index and trajectory sensitivity. It is also shown that the optimal control so obtained will result in a system whose performance index and transient response are low sensitive to small varation in ship's time constant.

  • PDF

A study on the Intelligent Voltage Control System (전력계통의 지능형 전압제어시스템에 관한 연구)

  • Lee, Heung-Jae;Yu, Won-Kun;Wang, In-Soo;Kang, Hyun-Jae;Shin, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.944-949
    • /
    • 2012
  • As modern power systems become large and complicated, the automated voltage and reactive power control system is required in most developed countries due to the recent amazing progress of computer net works and information thechnology. So far the voltage control has been depend on human operator in korean power system. This paper presents an intelligent voltage control system based on sensitivity analysis and artificial intelligence technology. Detailed state space modeling technique is discussed and a new performance index is proposed to speed up the searching performance of the expert system. As the searching strategy is very important factor of the speed of expert system the least first search algorithm is applied using this performance index. The intelligent voltage control system is applied to the Jeju power system. As a result, case studies showed a promissing application of the intelligent voltage control system.

Piezoelectric Sensitivity Analysis for Vibration Control of a Plate (평판의 진동제어를 위한 압전감도 해석)

  • Hwang, Jin-Kwon;Song, Chul-Ki;Choi, Chong-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.4
    • /
    • pp.239-246
    • /
    • 2000
  • This paper investigates optimal locations of piezoelectric actuators and sensors on a thin plate. To locate actuators and sensors properly is important in controlling modal vibrations well. A piezoelectric sensitivity index is introduced to select optimal locations for vibration control of each mode. The sensitivity expresses the efficiency of actuating and sensing modal forces according to locations of a piezoelectric material on a plate. The piezoelectric sensitivities for two types of plate, an all-clamped plate, and a free-free plate, are derived theoretically and are verified experimentally. Also, its usefulness Is experimentally shown to control vibration of the all-clamped plate with piezoelectric materials.

  • PDF

Development of RGBW Dimming Control Sensitivity Lighting System based on the Intelligence Algorithm (지능형 알고리즘 기반 RGBW Dimming control LED 감성조명 시스템 개발)

  • Oh, Sung-Kwun;Lim, Sung-Joon;Ma, Chang-Min;Kim, Jin-Yul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.3
    • /
    • pp.359-364
    • /
    • 2011
  • The study uses department of the sensitivity and fuzzy reasoning, one of artificial intelligence algorithms, so that develop LED lighting system based on fuzzy reasoning for systematical control of the LED color temperature. In the area of sensitivity engineering, by considering the relation between color and emotion expressed as an adjective word, the corresponding sensitivity word can be determined, By taking into consideration the relation between the brain wave measured from the human brain and the color temperature, the preferred lesson subject can be determined. From the decision of the sensitivity word and the lesson subject, we adjust the color temperature of RGB (Red, Green, Blue) LED. In addition, by using the information of the latitude and the longitude from GPS(Global Positioning System), we can calculate the on-line moving altitude of sun. By using the sensor information of both temperature and humidity, we can calculate the discomfort index. By considering the altitude of sun as well as the value of the discomfort index, the illumination of W(white) LED and the color temperature of RGB LED can be determined. The (LED) sensitivity lighting control system is bulit up by considering the sensitivity word, the lesson subject, the altitude of sun, and the discomfort index The developed sensitivity lighting control system leads to more suitable atmosphere and also the enhancement of the efficiency of lesson subjects as well as business affairs.

Integrated Structural and PD-Control Optimization of Flexible Rotor Supported by Active Magnetic Bearings

  • Jeon, Han-Wook;Lee, Chong-Won;Watanabe, Toru
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.736-742
    • /
    • 2008
  • This paper proposes new searching algorithm for the optimal PD gains of flexible rotor supported by active magnetic bearings. Under the assumption of linearized bearing parameters with respect to PD gains, the performance index in quadratic form is defined and steepest descent method is adopted for determining local minimum. Moreover, the eigenpair sensitivity concept is utilized to evaluate the sensitivity of performance index. To evaluate the effectiveness of suggested algorithm, the finite element model is constructed and its reduced model is retained in modal domain. Given starting gains, the optimal gains are successfully found and the control performance is demonstrated by simulation to show the efficiency of the proposed method.

  • PDF

Sensitivity Analysis and Parameter Estimation of Activated Sludge Model Using Weighted Effluent Quality Index (가중유출수질지표를 이용한 활성오니공정모델의 민감도 분석과 매개변수 보정)

  • Lee, Won-Young;Kim, Min-Han;Kim, Young-Whang;Lee, In-Beum;Yoo, Chang-Kyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1174-1179
    • /
    • 2008
  • Many modeling and calibration methods have been developed to analyze and design the biological wastewater treatment process. For the systematic use of activated sludge model (ASM) in a real treatment process, a most important step in this usage is a calibration which can find a key parameter set of ASM, which depends on the microorganism communities and the process conditions of the plants. In this paper, a standardized calibration protocol of the ASM model is developed. First, a weighted effluent quality index(WEQI) is suggested far a calibration protocol. Second, the most sensitive parameter set is determined by a sensitive analysis based on WEQI and then a parameter optimization method are used for a systematic calibration of key parameters. The proposed method is applied to a calibration problems of the single carbon removal process. The results of the sensitivity analysis and parameter estimation based on a WEQI shows a quite reasonable parameter set and precisely estimated parameters, which can improve the quality and the efficiency of the modeling and the prediction of ASM model. Moreover, it can be used for a calibration scheme of other biological processes, such as sequence batch reactor, anaerobic digestion process with a dedicated methodology.

A Sensitivity and Performance Analysis for Torque Mode Switching on 2MW Direct Drive Wind Turbine Generator (2MW급 직접구동형 풍력발전기의 풍황 민감도 및 토크모드 스위칭 성능 해석)

  • Rho, Joo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1455-1460
    • /
    • 2014
  • Wind turbine generators were designed on general regulations of wind condition. At real situations, it could be different from the design conditions. There are many control methods and definitions of transient region, because an efficient wind turbine generator control logic is the important matter in generator performance and annual energy production at real conditions. In this document, the power generation sensitivity for wind speed and turbulence intensities was defined to know the sensitive transient region. Wind conditions are applied for the ranges of 7~10m/s mean wind speed and 14~20% turbulence intensity. The sensibility of HR-D86 wind generator was increased in transient region(8~10m/s) on power curve diagram through a torque control to a pitch control. And then GH-bladed simulations was performed for performance analysis of the torque mode switching in transient region on 2MW direct drive wind generator(HR-D86) which is designed IEC class II for onshore. Through the sensitivity and performance analysis, the sensitivity for real wind condition could be the performance index for an wind generator. And the torque mode switching in transient region can increase the mean power generation on HR-D86 wind turbine generator.

Voltage Collapse Approximity Indeces Using The Loss Sensitivity (손실 감도를 이용한 전압붕괴 근접도 지표)

  • Kim, Yang-B.;Kim, Kern-J.;Chu, Jin-B.;Kim, Woen-K.;Lee, Sang-J.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.218-221
    • /
    • 1992
  • Recent years voltage collapse phenomenon have a great attention to power system engineers. As the system size increases the voltage problem shows a very complicated and the reactive power contol problem becomes more difficult. This paper gives an efficient methods for calculating voltage collapse proximity index based on the reactive power loss sensitivity and real power loss sensitivity. The system voltages are tightly associated with the system reactive power, so the proposed voltage collapse proximity index is very usefull for the system voltage control problems. Numerical examples showed a good and reliable results.