• Title/Summary/Keyword: Continuous-time filter

Search Result 201, Processing Time 0.03 seconds

Design of the 5th-order Elliptic Low Pass Filter for Audio Frequency using CMOS Switched Capacitor (CMOS 스위치드 캐패시터 방식의 가청주파수대 5차 타원 저역 통과 여파기의 설계 및 구현)

  • Song, Han-Jung;Kwack, Kae-Dal
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.1
    • /
    • pp.49-58
    • /
    • 1999
  • This paper describes an integrated low pass filter fabricated by using $0.8{\mu}m$ single poly CMOS ASIC technology. The filter has been designed for a 5th-order elliptic switched capacitor filter with cutoff frequency of 5khz, 0.1dB passband ripple. The filter consists of MOS swiches poly capacitors and five CMOS op-amps. For the realization of the SC filter, continuous time transfer function H(s) is obtained from LC passive type, and transfered as discrete time transfer H(z) through bilinear-z transform. Another filter has been designed by capacitor scaling for reduced chip area, considering dynamic range of the op-amp. The test results of two fabricated filters are cutoff frequency of 4.96~4.98khz, 35~38dB gain attenuation and 0.72~0.81dB passband ripple with the ${\pm}2.5V$power supply clock of 50KHz.

  • PDF

A real Implemention of an Adaptive Self-tuning Filter Using an NEC 7720 DSP (NEC 7720 DSP를 이용한 적응자기 동조필터의 실시간 구현)

  • 이연석;이상욱;이장규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.5
    • /
    • pp.367-376
    • /
    • 1987
  • In this paper we have disigned and implemented a real time ALE (adaptive line enhancer) using a high speed digital processor,NEC 7720. For the ALE system, we have employed an adaptive LMS(least mean square) algorithm proposed by Widrow and Hoff and a 32-order FIR(finite impulse response) filter. Extensive computer simulations have been performed to investigate the peformance of the ALE and to determine necessary parameters for hardware design. The developed software for an NEC 7720 was tested in real time operation using an NEC7720 hardware emulator. The ALE has been tested by sinusoidal waves and real CW (continuous wave) signals. It was found that the experimental results were well agreed with the computer simulation results. Thus it can be concluded that the ALE is useful for detection and enhancement of a sinusoidal signal which is corrupted by an additive Gaussian noise.

  • PDF

New method for LQG control of singularly perturbed discrete stochastic systems

  • Lim, Myo-Taeg;Kwon, Sung-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.432-435
    • /
    • 1995
  • In this paper a new approach to obtain the solution of the linear-quadratic Gaussian control problem for singularly perturbed discrete-time stochastic systems is proposed. The alogorithm proposed is based on exploring the previous results that the exact solution of the global discrete algebraic Riccati equations is found in terms of the reduced-order pure-slow and pure-fast nonsymmetric continuous-time algebraic Riccati equations and, in addition, the optimal global Kalman filter is decomposed into pure-slow and pure-fast local optimal filters both driven by the system measurements and the system optimal control input. It is shown that the optimal linear-quadratic Gaussian control problem for singularly perturbed linear discrete systems takes the complete decomposition and parallelism between pure-slow and pure-fast filters and controllers.

  • PDF

A new continuous-time current-mode integrator for realization of low-voltage current-mode CMOS filter (저전압 전류모드 CMOS 필터 구현을 위한 새로운 연속시간 전류모드 적분기)

  • 방준호;조성익;김동용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.1068-1076
    • /
    • 1996
  • In this paper, a new continuous-time current-mode integrator as basic building block of the low-voltage analyog current-mode active filters is proposed. Compared to the current-mode integrator which is proposed by Zele, the proposed current-mode integrator had higher unity gain frequency and output impedance in addition to lower power dissipation. And also, a current-mode third-order lowpass active filter is designed with the proposed current-mode integrator. The designed circuits are fabricated using the ORBIT's $1.2{\mu}{\textrm{m}}$ deouble-poly double-metal CMOS n-well process. The experimental results show that the filter has -3dB cutoff frequency at 44.5MHz and 3mW power dissipation with single 3.3V power supply and also $0.12mm^{2}$ chip area.

  • PDF

Real-Time Continuous-Scale Image Interpolation with Directional Smoothing

  • Yoo, Yoonjong;Shin, Jeongho;Paik, Joonki
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.3
    • /
    • pp.128-134
    • /
    • 2014
  • A real-time, continuous-scale image interpolation method is proposed based on a bilinear interpolation with directionally adaptive low-pass filtering. The proposed algorithm was optimized for hardware implementation. The ordinary bi-linear interpolation method has blocking artifacts. The proposed algorithm solves this problem using directionally adaptive low-pass filtering. The algorithm can also solve the severe blurring problem by selectively choosing low-pass filter coefficients. Therefore, the proposed interpolation algorithm can realize a high-quality image scaler for a range of imaging systems, such as digital cameras, CCTV and digital flat panel displays.

Reduction of waterborne microorganisms in treated domestic wastewater for reuse in agriculture: Comparison between floating media filter and sand filter

  • Semsayun, Chalanda;Chiemchaisri, Wilai;Chiemchaisri, Chart;Patchanee, Nopparat
    • Environmental Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.403-409
    • /
    • 2015
  • This study aims to investigate the use of a floating media filter (FMF) to eliminate waterborne microorganism in treated domestic wastewater for reuse in agriculture. A conventional sand filter (SF) was used concurrently to compare treated water quality. The total/fecal coliforms and somatic coliphage were employed as fecal indicators. The result showed that the FMF was fed with 3 times higher infiltration rate ($15m^3/m^2.h$) than that in the SF ($5m^3/m^2.h$), in which both filters gave similar coliform removal at 6 hours operation. The somatic coliphage elimination tended to increase with operational time for the FMF while that of the SF showed decreasing trend. When a 24 hour continuous operation was applied for the FMF, it showed better removal of somatic coliphage (78%), fecal coliforms (60%) and total coliforms (56%) than that of 6 hour operation. In conclusion, the FMF gave better performance than the SF did by producing a good quality of treated water for agriculture in terms of waterborne microorganisms including turbidity and suspended solids.

Low Pass Filter Design using CMOS Floating Resister (CMOS Floating 저항을 이용한 저역통과 필터의 설계)

  • 이영훈
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.77-84
    • /
    • 1998
  • The continuous time signal system by development of CMOS technology have been receiving consideration attention. In this paper, Low pass filter using CMOS floating resistor have been designed with cut off frequency for speech signal processing. Especially a new floating resistor consisting entirely of CMOS devices in saturation has been developed. Linearity within $\pm$0.04% is achieved through nonlineartiy via current mirrors over an applied range of $\pm$1V. The frequency response exceeds 10MHz, and the resistors are expected to be useful in implementing integrated circuit active RC filters. The low pass filter designed using this method has simpler structure than switched capacitor filter. So reduce the chip area. The characteristics of the designed low pass filter using this method are simulated by pspice program.

  • PDF

Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process (여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.

Earthquake time-frequency analysis using a new compatible wavelet function family

  • Moghaddam, Amir Bazrafshan;Bagheripour, Mohammad H.
    • Earthquakes and Structures
    • /
    • v.3 no.6
    • /
    • pp.839-852
    • /
    • 2012
  • Earthquake records are often analyzed in various earthquake engineering problems, making time-frequency analysis for such records of primary concern. The best tool for such analysis appears to be based on wavelet functions; selection of which is not an easy task and is commonly carried through trial and error process. Furthermore, often a particular wavelet is adopted for analysis of various earthquakes irrespective of record's prime characteristics, e.g. wave's magnitude. A wavelet constructed based on records' characteristics may yield a more accurate solution and more efficient solution procedure in time-frequency analysis. In this study, a low-pass reconstruction filter is obtained for each earthquake record based on multi-resolution decomposition technique; the filter is then assigned to be the normalized version of the last approximation component with respect to its magnitude. The scaling and wavelet functions are computed using two-scale relations. The calculated wavelets are highly efficient in decomposing the original records as compared to other commonly used wavelets such as Daubechies2 wavelet. The method is further advantageous since it enables one to decompose the original record in such a way that a clear time-frequency resolution is obtained.

Analysis of Changes and Factors Influencing IAQ in Subway Stations Using IoT Technology after Bio-Filter System Installation (IoT 기반 지하역사 내 바이오필터시스템 설치에 따른 실내공기질 변화 및 영향 요인 분석)

  • Yang, Ho-Hyeong;Kim, Hyung-Joo;Bang, Sung-Won;Cho, Heun-Woo;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.410-424
    • /
    • 2021
  • Background: Subway stations have the characteristics of being located underground and are a representative public-use facility used by an unspecified number of people. As concerns about indoor air quality (IAQ) increase, various management measures are being implemented. However, there are few systematic studies and cases of long-term continuous measurement of underground station air quality. Objectives: The purpose of this study is to analyze changes and factors influencing IAQ in subway stations through real-time continuous long-term measurement using IoT-based IAQ sensing equipment, and to evaluate the IAQ improvement effect of a bio-filter system. Methods: The IAQ of a subway station in Seoul was measured using IoT-based sensing equipment. A bio-filter system was installed after collecting the background concentrations for about five months. Based on the data collected over about 21 months, changes in indoor air quality and influencing factors were analyzed and the reduction effect of the bio-filter system was evaluated. Results: As a result of the analysis, PM10, PM2.5, and CO2 increased during rush hour according to the change in the number of passengers, and PM10 and PM2.5 concentrations were high when a PM warning/watch was issued. There was an effect of improving IAQ with the installation of the bio-filter system. The reduction rate of a new-bio-filter system with improved efficiency was higher than that of the existing bio-filter system. Factors affecting PM2.5 in the subway station were the outdoor PM2.5, platform PM2.5, and the number of passengers. Conclusions: The IAQ in a subway station is affected by passengers, ventilation through the air supply and exhaust, and the spread of particulate matter generated by train operation. Based on these results, it is expected that IAQ can be efficiently improved if a bio-filter system with improved efficiency is developed in consideration of the factors affecting IAQ and proper placement.