• Title/Summary/Keyword: Contamination source

Search Result 515, Processing Time 0.026 seconds

A Study of Korean Efficiency of PV PCS (태양광 인버터의 한국형 전력변환 효율에 관한 연구)

  • Kim, Jeong-Hwan;Yu, Byung-Gyu;So, Jung-Hun;Lee, Ki-OK;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.356-360
    • /
    • 2009
  • Recent global environmental pollution and contamination and depletion of limited fossil energy prices surge as an energy source to replace it depending on wind, fuel cells and solar power and other renewable and pollution free renewable energy is of interest in increase. The photovoltaic systems are pollution-free, unlimited energy source, and easy to install because it is rated as the most valuable renewable energy sector and the prevalence is spreading throughout the world. Photovoltaic systems at one end of the stable development of the role that solar power inverter applications can be the most important. No matter how much power the solar arrays, even if the inverter output in the normally if he's no use. These photovoltaic inverters to evaluate the performance of the inverter efficiency measures that can be called directly. This way of measuring the efficiency of solar inverters in Europe efficiency and CEC efficiency is currently being used. In this paper, until now about how to measure the efficiency of solar power inverter technology and the new Korean Meteorological Solar Insolation data analysis to derive weights based on this inverter efficiency for Korea is to offer.

  • PDF

Microscopic Examination of Fracture Particles on the Surface of Ir-192 Sealed Source and Ultrasonic Cleaning (Ir-192 밀봉선원의 표면오염 방지)

  • Kuk, Il Hiun;Park, Chun Deuk;Koo, Ja Ho
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • The iridium disc, generally used in industrial radiography, is examined to find the fracture morphology and fine particles remaining on the shear blank surface. Randomly selected 1,200 discs were observed under a scanning electron microscope tilted more than $45^{\circ}$. Fracture surfaces are classified into three groups: (1) surface fall-out, (2) fracture on the edge and (3) multi-step brittle fracture, which shows the mutual relationship between the fracture morphology and remaining particles. Fracture particles were removed by cleaning the discs in a ultrasonic bath with acetone and collected at the bottom. Removed number of the particles were counted for each different group of fracture surfaces. Followings are conclusions: (1) About 80.5% of discs (966/1,200), have sound plastic shear surfaces with particles remained. (2) About 2% discs accompany surface fall-out's having large particles tens of ${\mu}m$, which is stable not to be pulled out even after the considerably long time of ultrasonic cleaning. (3) About 5% discs contain the fractures on the edge and the particles are removed thoroughly within 30 minutes. (4) 234 discs out of 1,200 discs have multi-step fracture surfaces whose particles never removed in a short period of time but come out very slowly. Such a disc having multiple-step fracture is attributed to the promate cause to the 'leaker'. It is noted here that the discs having mutiple-step fractures should be treated separately with special care, and it is need to study how to treat them.

Characterization of Atmospheric Dispersion Pattern from Large Sources in Chungnam, Korea (충남지역 대형사업장의 대기오염물질 확산 특성 파악)

  • Choi, Woo Yeong;Park, Min Ha;Jung, Chang Hoon;Kim, Yong Pyo;Lee, Ji Yi
    • Particle and aerosol research
    • /
    • v.17 no.3
    • /
    • pp.55-69
    • /
    • 2021
  • Chungnam region accounts for the largest SOX (22.8%) emission with the second-largest NOX (10.8%) emission in Korea due to the integration of many large industrial sources including a steel mill, coal-fired power plants, and petrochemical complex. Air pollutants emitted by large industrial sources can cause harmful problems to humans and the environment. Thus, it is necessary to understand dispersion patterns of air pollutants from large industrial sources in Chungnam to characterize atmospheric contamination in Chungnam and the surrounding area. In this study, seasonal atmospheric dispersion characteristics for SOX, NOX, and PM2.5 from ten major point sources in Chungnam were evaluated using HYSPLIT 4 model, and their contributions to SO2, NO2 concentrations in the regions near the source areas were estimated. The predictions of the HYSPLIT 4 model show a seasonal different dispersion pattern, in which air pollutants were dispersed toward the southeast in winter while, northeast in summer. In summer, due to weaker wind speed, air pollutants concentrations were higher than in winter, and they were dispersed to the metropolitan area. The local emissions of air pollutants in Taean area had a greater influence on the ambient SO2 and NO2 concentrations at Taean, whereas SOX and NOX emissions from large sources located at Seosan showed relatevely little effect on the ambient ambient SO2 and NO2 concentrations at Seosan.

Investigation on Geochemical Characteristics of Heavy Metals in Soils in the Vicinity of Samcheonpo and Hadong Coal-Fired Power Plants in Korea (국내 삼천포와 하동 석탄 화력발전소 주변 토양 내 중금속의 지구화학적 특성 조사)

  • Song, Chang-Woo;Han, Hyeop-Jo;Lee, Jong-Un
    • Economic and Environmental Geology
    • /
    • v.52 no.2
    • /
    • pp.141-158
    • /
    • 2019
  • The quantity of heavy metals in agricultural surface and subsurface soils around coal-fired power plants located in Samcheonpo and Hadong, Gyeongnam Province, were determined. The analytical results for 48 and 61 soils in Samcheonpo and Hadong, respectively, showed that the concentrations of Cu, Hg, Ni, Pb, and Zn were below the warning criteria regulated by Korean Soil Conservation Act; however, Cd in 38 and 13 soils in Samcheonpo and Hadong, respectively, exceeded the criterion. As a result of calculation of the geoaccumulation index and the enrichment factor, the soils were extremely contaminated with Cd and such high loading of Cd to the soils was due to anthropogenic source(s). Sequential extraction of the soils, however, showed that heavy metals including Cd existed as hardly extractable phases, which represented a low bioavailability of the heavy metals. Our results indicated that Cd contamination around the coal-fired power plants was due to artificial source(s) and may unlikely deteriorate nearby ecosystems.

The Analysis of the Collimator & Radiation Shield for the Radiation Sensor for the 3Dimension Radiation Detection (3차원 방사선 탐지장치용 검출센서의 차폐체 및 Collimator 구조 분석 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Park, Sumg-Hun;Jeong, Sang-Hun;Kim, Jong-Ryul;Choi, Myung-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.707-709
    • /
    • 2014
  • The radiation sources leaked from large-scale radiation leak accident like the Fukushima nuclear power plant accident or nuclear explosions can cause to the very large damage for us. So that the damage can be minimized, we have being developed a detector that can providing information about the location of the source to remove dangerous substances quickly than the conventional single detector. In this paper, we designed and implemented the radiation shield and the collimator for the development of the stereo radiation detector to detect contamination things using MCNP Simulation. And we analysed the test results of the radiation shield and collimator using the radiation source. The results of this paper will be used as the basis for improving the efficiency of the stereo radiation detector being studied currently.

  • PDF

Real-time wireless marine radioactivity monitoring system using a SiPM-based mobile gamma spectroscopy mounted on an unmanned marine vehicle

  • Min Sun Lee;Soo Mee Kim;Mee Jang;Hyemi Cha;Jung-Min Seo;Seungjae Baek;Jong-Myoung Lim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2158-2165
    • /
    • 2023
  • Marine radioactivity monitoring is critical for taking immediate action in case of unexpected nuclear accidents at nuclear facilities located near coastal areas. Especially when the level of contamination is not predictable, mobile monitoring systems will be useful for wide-area ocean radiation survey and for determination of the level of radioactivity. Here, we used a silicon photomultiplier and a high-efficiency GAGG crystal to fabricate a compact, battery-powered gamma spectroscopy that can be used in an ocean environment. The developed spectroscopy has compact dimensions of 6.5 × 6.5× 8 cm3 and weighs 560 g. We used LoRa, a low-power wireless protocol for communication. Successful data transmission was achieved within 1.4 m water depth. The developed gamma spectroscopy was able to detect radioactivity from a 137Cs point source (3.7 kBq) at a distance of 20 cm in water. Moreover, we demonstrated an unmanned radioactivity monitoring system in a real sea by combining unmanned surface vehicle with the developed gamma spectroscopy. A hidden 137Cs source (3.07 MBq) was detected by the unmanned system at a distance of 3 m. After successfully testing the developed mobile spectroscopy in an ocean environment, we believe that our proposed system will be an effective solution for mobile real-time marine radioactivity monitoring.

A Study on the Characteristics of Water Pollution in Rural Areas (농촌유역(農村流域)에서의 수질오염(水質汚染) 특성(特性)에 관한 연구(硏究))

  • Kim, Han-Tea;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.2
    • /
    • pp.129-143
    • /
    • 1993
  • The objective of this study is to understand the status of the water pollution in rural areas and to furnish a basic material for the management of the water pollution in rural areas. For this purpose, the Bokha river basin, Ichon-Gun, Kyungki-Do considering as a typical agricultural area was selected as a representative experimental watershed. The characteristics of water pollution in streams of the Bokha river basin was revealed by investigating and analyzing data collected for the source of pollution, water qualities in reaches of the stream, the degree of contribution to the river contamination by pollution mass produced from each source, and the status of the self-purification at the main stream. The most important source of the water pollution in investigated watershed was livestock, and the next important one were in the order of population, land use, and industry. The water quality of the Bokha river was relatively favorable judging from the BOD and COD concentration, however since the concentration of T-N and T-P showed significantly large values, it was concluded that the river was seriously contaminated by the nutrient material. The main cause of the river contamination was proved due to livestock waste. For the T-N, both land use and livestock were much more contributied to the pollution than any other source, which characterized the typical water pollution of rural areas. Run-off ratios for the Bokha river tributaries to the main stream were changed according to the similar trend to the variation of discharges in the branch streams. For the value of the self-purification constant at the main stream, it showed smaller value in the downstream reach than the middle-stream and upstream reaches, where could possibly have smaller reoxidation action due to slower velocity and deeper water depth.

  • PDF

Characteristics Evaluation of Non Point Source Treatment Facilities in Construction Site (건설 현장 내 비점오염원 처리 시설의 제거 특성 평가)

  • Choi, Younghoa;Jeong, Seolhwa;Kim, Changryong;Kim, Hyosang;Oh, Jihyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.53-62
    • /
    • 2009
  • This study was conducted to investigate characteristics of the non-point source pollution under construction and evaluate available pollution control methods. Suspended solid loading is high when soil disturbs by rainfall and this phenomenon is much more severe at the initial stage of construction than at the final one. There are three methods available for erosion and sediment control, which are check dam, silt fence, and geotextile. Check dam and silt fence are for control of suspense solids and geotextile is for preventing soil erosion during rainfall. They can be installed as temporary control facilities at construction sites. From the comparison of those methods, it was found that geotextile method was the most efficient for the runoff control of non-point source pollution. Check dam and silt fence can remove suspense solids by pore spaces to some degree, but the removal of pollutants mainly occurs through sedimentation. Because the temporary control facilities have limited removal efficiency of pollutant, they often cause civil claims and contamination of water environment. Hence, using a pressurized filtration system along with temporary control facilities, highly enhanced treatment efficiency was anticipated. In addition, the loading capacity of these techniques depends on filtration velocity and input loading. And their pre-treatments are necessary for efficient operation.

  • PDF

Drainage and Treatment Characteristics of Runoff by Media (여재에 따른 도로면 유출수의 배수 및 처리특성)

  • Kim, Seog-gu;Yun, Sang-Ieen;Kim, Young-im;Lee, Yong-jae;Kim, Ree-ho;Kim, Jong-oh
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.500-505
    • /
    • 2004
  • While more attention has been paid in recent years to urban point source pollution control, no considerable measures have been taken to control urban non-point source pollution. Contaminants from non-point sources deposited on urban impermeable surfaces such as road and highway are easily released to the public waters by rainfall, leading to the deterioration in water quality in urban area. The present study investigated a system using filter media to reduce the level of contamination in urban road runoff. Three different media, designated as J-P (polypropylene, blowing type), B-P (polypropylene, fiber type), and P-F (Polyvinyl alcohol, cube and sheet type) were evaluated on the basis of pollutant removal efficiency as well as hydraulic property. Experiments were peformed using a 1/4-scale treatment unit at various pollutant roading and rainfall intensity with real rainwater runoff collected from road surfaces. The results at different rainfall intensities shows that the medium J-P is superior to the other media for water permeability. J-P was not blocked at 10 mm/hr rainfall and its permeability was stable. On the other hand, B-P and P-F resulted in substantial overflow ratio even at I mm/hr rainfall intensity. Comparing treatment efficiencies for suspended solids, all media showed similar removal ranged from 91 % to 95%. However, J-P seems to be better than the other media considering its higher water permeability. J-P and P-F, both hydrophobic, yielded over 76% of heavy metal removal. But, the hydrophilic media B-P showed much smaller removal ranging from 26% to 47%. This indicates that J-P and P-F are beneficial to remove heavy metal due to their hydrophobic property. The treatment efficiencies over PAHs (poly aromatic hydrocarbons) showed the similar removal efficiency ranging from 66% to 97% for all three media.

Source Tracking of Fecal Contamination at Ansan Stream Using Multiple Antibiotic Resistance Analysis (Multiple Antibiotic Resistance Analysis를 이용한 안산천 분변성 미생물 오염원 추적)

  • Lee, Sang-Min;Lee, Jin;Kim, Moon-Il;Yoon, Hyun-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.827-833
    • /
    • 2011
  • In this study, fecal nonpoint pollutant sources tracking were conducted on Ansan stream. Multiple Antibiotic Resistance Analysis (MARA) method used in this study is based on the premise that fecal bacteria derived from intestine of human or animal has each different resistance for antibiotics. First of all, a database for known sources should be established to use the method and then, an unknown sample was applied on the database to find unknown sources by statistical analysis. The Ansan stream was considered with divided condition into three parts: upper (livestock farming area), mid (old section of the city), and downstream (new section of the city) to search an environmental influence of the stream basin. As results of the statistical analysis, it could be estimated that the upper stream area was influenced by animals due to the nature of influence for the livestock farms located in this area because livestock were classified as percentages of 45.8% in 3-way method divided into livestock, pet and human. In case of midstream and downstream, the human influence was remarkable as percentage of 60% and 80%, respectively. From these results, it could be judged that the MARA method is useful in source tracking the non-point pollutant sources because the MARA results correspond to which predictable non-point pollutant sources by a field study. Also, it is expected that a more effective source tracking will be possible as establishing database of each area.