• 제목/요약/키워드: Contamination of saline

검색결과 53건 처리시간 0.023초

수술에 사용하는 생리식염수의 오염수준 변화 (A Study on the Contamination of Saline Used in the Operation)

  • 윤혜상
    • 대한간호학회지
    • /
    • 제25권1호
    • /
    • pp.99-109
    • /
    • 1995
  • Post-operative wound infections have been the serious problems in nursing care in the operating room and appear to be strongly related to the infection occurring during the operation. The purpose of this study is to identify the level of contamination in saline used in the operation and also examine the correlation between the contaminated saline and the length of the operation, and unclean atmospheric factor. Subjects for this study include 13 cases of operation performed at the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between Oct. 6 through Dec. 10, 1994 by the author and anurse who worked in the operating room. For the study, multiple batches of saline sample were collected at the various time intervals duringthe operation and filtered through the membrane filters. Viable microorganisms retained on the filters were cultured on the appropriate culture media and the levels of existing cells in saline were enumerated according to Koch's method. In the analyses of the data, Pearson's correlation coefficient was obtained for the examination of relationship between the length of operation and numbers of microorganisms existing in saline and for the comparison of the differences in numbers if microrganisms in saline sample collected at the various operative stages, e. g. pre-incision, excision and skin suturing stages, ANOVA and Scheff Tests were performed. The results of this study are summarized as follows. 1) The lenth of the operation and numbers of microorganisms in the saline used in the operation appeared to be significantly correlated (r=0.5467, P<0,001). 2) In case of saline exposed to air, but not used in the operation, the length of exposure to the air and the numbers of microorganisms present in saline also showed an apparent correlation(r=0.5087, P<0. 001). 3) The frequencies of occurrence of microorganisms in saline used in the operation and in saline exposed only to the air in the given time showed significant differences(t=3.73, p=.0000). 4) In case of saline used in the operation, there is significant differences in its numbers of contained microorganisms between the operative stages ; pre-incision, excision, and skin suture (F=17.7500, p=.0000). 5) In case of saline exposed only to the air in the given time, there is significant differences in its numbers of contained microorganisms between the operative stages . pre-incision, excision, and skin suture(F=6.3807, p=.00031).

  • PDF

Comparison of hydrochemical informations of groundwater obtained from two different underground storage systems

  • Lee, Jeonghoon;Kim, Jun-Mo;Chang, Ho-Wan
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.110-113
    • /
    • 2002
  • Statistical- based, principal component analysis (PCA) was applied to chemical data from two underground storage systems containing LPG to assess the usefulness of such technique at the initial stage (Pyeongtaek) or middle stage (Ulsan) of hydrochemical studies. For the first case, both natural and anthropogenic contamination characterize regional groundwater. Saline water buffered by Namyang lake affects as a natural factor, whereas cement grouting influence as an artificial factor. For the second study area, contaminations due to operation of LPG caverns, such as disinfection activity and cement grouting effect, deteriorate groundwater quality. This study indicates that principal component analysis would be particularly useful for summarizing large data set for the purpose of subsurface characterization, assessing their vulnerability to contamination and protecting recharge zones.

  • PDF

Radiocobalt의 체내 오염(汚染)에 대(對)한 제염효과(除染效果) (An Experimental Study on Internal Decontamination Radiocobalt)

  • 정인용;김태환;정현우;진수일;윤택구
    • Journal of Radiation Protection and Research
    • /
    • 제13권1호
    • /
    • pp.31-41
    • /
    • 1988
  • 국내 원자력(原子力) 산업(産業)의 시설증대(施設增大)로 방사성핵종오염(放射性核種汚染)의 가능성이 날로 증가되고 있음에도 불구하고 종사자 및 인근주민에 대한 진료대책(診療對策)에 관한 연구가 전무한 실정에 있어 이에 대한 기초자료마련의 일환인 응급처치방안을 수립코자 $^{58}CoCl_2\;1{\mu}Ci$를 마우스(NIH-(GP))의 복강내(腹腔內)에 투여한 후 $CaNa_3$ DTPA 8.4mg/0.2ml-saline, $CoNa_3$ DTPA 8.4mg/0. 2ml-saline, saline 5ml 등(等)을 동시에 각각 투여하였으며, cobalt의 전신잔존량(全身殘存量), 체내분포 및 요내(尿內) 함유(含有)된 양(量)을 측정(測定)하기 위해 투여 후(後) 4, 8, 12, 48시간, 그리고 7일에 MCA의 Ge-detector로 방사능(放射能)을 계측(計測)하였고, 또한 각 실질장기내(實質臟器內) 잔존(殘存)된 cobalt의 방사능(放射能)을 측정(測定)하기 위하여 각 group당 6마리의 마우스를 도살해체하여 측정(測定)하였던 바 다음과 같은 결론을 얻었다. $CoNa_3$ DTPA 처치군(處置群)에서는 오염(汚染)된 방사성(放射性) cobalt의 전신잔존율(全身殘存率)의 감소(減少) 및 배설율(排泄率) 증가(增加)에 유효한 효과(效果)가 있었으며, systemic contamination에 대한 방어효과는 $CoNa_3$ DTPA, $CaNa_3$ DTPA 그리고 saline의 순(順)으로 유효하였다. 결론적으로 본 실험결과로 볼때 방사성(放射性) cobalt의 체내오염에 대한 긴급처치(緊急處置)는 $CoNa_3$ DTPA와 다량의 물을 동시에 투여함으로써 체내오염된 방사성(放射性) cobalt의 배설(排泄)을 촉진(促進)시킬 것으로 사료된다.

  • PDF

일일 착용 콘택트렌즈의 연속 착용에 따른 세균 오염 (Microorganism Contamination from Wearing One-Day Disposable Contact Lenses According to Wearing Time)

  • 최강원;장우영;이종욱;김수정
    • 미생물학회지
    • /
    • 제46권2호
    • /
    • pp.152-156
    • /
    • 2010
  • 연성 콘택트렌즈 종류의 하나인 일회용 렌즈는 사용상 편리함을 주는 반면 다양한 안과적 감염성 질환을 초래한다. 안 질환을 유발하는 미생물로는 Acanthamoeba, Bacteria, Fungi 등이 있다. 렌즈 착용시 손을 이용함으로 다양한 미생물 오염은 근절이 불가피한 실정이다. 다양한 미생물의 오염으로 인해 감염성 각막염을 유발하나 정확한 미생물 동정은 미비한 상태이다. 이런 이유로 렌즈를 세척하기 위해 흔히 사용하는 식염수와 ReNu Solution (Bausch and Lomb Company, USA)의 2그룹으로 나누고 식염수와 ReNu Solution을 사용하여 1, 3, 5 10 그리고 15일에 따라 미생물 오염의 정도를 살펴보고 분리되는 미생물을 동정하고자 하였다. 대구시 D대학 안경광학과 재학생들의 안과적 건강상태를 조사한 후 그룹별 10명씩 지정하였다. 일일 착용렌즈를 1일, 3일, 5일 10일, 그리고 15일에 따라 사용 후 배지에서 세균을 배양하였다. 배양된 집락을 선택하여 그람 염색한 결과, Gram-positive cocci 33%, Gram-negative cocci 2%, Gram-positive bacilli 34%, 그리고 Gram-negative bacilli 31%로 나타냈고 이러한 세균을 동정하기 위해 API kit와 VITEK system을 이용하였다. 그 결과 콘택트렌즈의 착용에 의해 유발되는 각막염의 원인세균으로 알려진 S. aureus, P. aeruginosa 등이 분리되었다. 본 연구에서는 연성렌즈의 하나인 일일 착용렌즈의 착용시 세척액에 따른 일반세균의 분포와 일회용 렌즈의 연속 착용에 따른 병원성 세균을 조사함으로 콘택트렌즈의 사용시 위생의 필요성을 시사한다.

Salt fog 내에서 옥외용 고분자 절연물의 내오손 성능 변화 (The Change of Contamination Performance of Polymeric Insulators for Outdoor Use)

  • 김정호;문중섭;박용판;김동명;원호상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.505-508
    • /
    • 1999
  • In this study, weight loss, ESDD, surface conductivity and leakage current were measured at the different saline solutions by salt fog method. The magnitude of leakage current was higher at higher conductivity of 2 S/m saline water, but weight loss ESDD and surface conductivity which are indices of degradation were lower. This is considered that the current includes mainly ohmic component which doesn\`t contribute to surface degradation. In addition, it is shown that FFT could be useful in measuring initial transition from hydrophobic to hydrophilic surface.

  • PDF

Radioiodine의 체내오염(體內汚染)에 대(對)한 긴급처치연구(緊急處置硏究) (Studies on the internal decontamination of radioiodine)

  • 정인용;김태환;정현우;진수일;윤택구
    • 대한수의학회지
    • /
    • 제28권2호
    • /
    • pp.391-396
    • /
    • 1988
  • Appreciable radiation exposures certainly occur in the workers who handle radioiodine in biochemical research, nuclear medicine diagnostics with the development of nuclear industries. But in the case of occurring the nuclear accidents, the early medical treatment of radiation injury should be necessary but little was reported in korea till now. Accordingly, to achieve of the basic data for protective roles and medical treatment of radiation injury, the present studies were carried out to evaluate the decontamination of radioiodine by the administration of the antithyroid drugs. The results observed are summarized as follows: 1. The administration of sodium iodide and potassium iodide results in rapid excretion of radioiodine and reduction of the whole body retention than the saline-only group. 2. Reguarding to thyroid protective effects, sodium iodide, potassium iodide and saline were effected significant in order. 3. In the control(saline) group, if administered with enough fluids, the whole body retention of radioiodine is reduced temporary shifts. But as far as radioprotective effects is concerned, saline was not more in the protective effects than the other groups. In conclusion, in case of nuclear accidents, if being administered sodium iodide and saline as quickly as possible, the radioprotective effects against the radiation hazard might be markedly increased in the internal contamination of radioiodine.

  • PDF

치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향 (TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH)

  • 김성오;최병재;이제호;손흥규
    • 대한소아치과학회지
    • /
    • 제25권2호
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

Microwave Plasma Sterilization System을 이용한 배추 절임수의 미생물 저감화 (Microbial Inactivation in Kimchi Saline Water Using Microwave Plasma Sterilization System)

  • 유동진;신윤지;김현진;송현정;이지혜;장성애;전소정;홍순택;김성재;송경빈
    • 한국식품영양과학회지
    • /
    • 제40권1호
    • /
    • pp.123-127
    • /
    • 2011
  • 김치 제조 공정에서 사용되는 김치 절임수의 미생물학적 안전성 확보와 재활용을 위한 연구로써, 본 연구에서는 microwave plasma sterilization system을 이용한 김치 절임수의 미생물 수 저감화를 위하여, E. coli O157:H7, L. monocytogenes, S. Typhimurium에 대한 살균 효과를 측정하고, 또한 사용한 김치 절임수에 본 장치를 적용하였다. 김치 공장에서 반복 사용한 절임수에 있는 coliform, E. coli, Salmonella spp., total aerobic bacteria, yeasts and molds가 사용 횟수가 늘어남에 따라 미생물 수가 증가하였다. Microwave plasma를 이용한 살균처리에서는 E. coli O157:H7, L. monocytogenes, S. Typhimurium의 $D_{10}$-value가 0.48, 0.52, 0.45 cycle로 각각 측정되었고, 또한 1회 사용한 절임수에 microwave plasma sterilization system 적용 시, coliform, E. coli, Salmonella spp., total aerobic bacteria, yeasts and molds 숫자가 유의적으로 감소하였다. 따라서 본 연구 결과, 김치공장의 김치 절임수를 재사용하기 위해서 microwave plasma sterilization system을 이용한 살균방법이 적합하다고 판단된다.

혈액오염이 Tricalcium Silicate 재료의 압출강도와 표면형태에 미치는 영향 (Effect of Blood Contamination on the Push-Out Bond Strength and Surface Morphology of Tricalcium Silicate Materials)

  • 박미선;김재환;최남기;김선미
    • 대한소아치과학회지
    • /
    • 제43권1호
    • /
    • pp.36-43
    • /
    • 2016
  • 이 연구의 목적은 혈액오염 시 Biodentine$^{(R)}$, Theracal$^{(R)}$, mineral trioxide aggregate(MTA)의 압출강도를 측정하고 표면형태를 관찰하는 것이었다. Biodentine$^{(R)}$, Theracal$^{(R)}$, MTA 각각의 재료를 2개의 그룹으로 나누었다. 대조군은 phosphate buffered saline 용액 조건에서, 실험군은 fetal bovine serum 조건에서 4일간 $37^{\circ}C$에서 보관하였다. 이후 압출강도를 측정하고 주사전자현미경을 이용하여 표면형태를 분석하였다. Biodentine$^{(R)}$과 Theracal$^{(R)}$은 모든 조건에서 MTA보다 유의하게 더 높은 압출강도를 보였고 혈액오염 시 모든 재료의 압출강도는 유의하게 감소하였다. 표면형태 관찰결과 혈액오염 후 모든 재료의 표면형태가 변화하였다. 혈액오염 조건에서 Biodentine$^{(R)}$과 Theracal$^{(R)}$은 MTA와 비교하여 더 높은 압출강도를 보였으므로 혈액오염 조건에 사용하기에 더 적절할 수 있다.

선식용 곡류원료의 위해미생물 제거를 위한 세척방법에 따른 효과 (Analysis of Harmful Microorganisms in Raw Cereal Materials and Processing Environment for Sunsik)

  • 김진희;양지영
    • 생명과학회지
    • /
    • 제22권4호
    • /
    • pp.565-568
    • /
    • 2012
  • 선식에 사용되는 곡류의 종류도 다양하고 오염미생물의 종류도 다양하여 곡류는 크기 모양 등을 고려하여 검정콩, 찹쌀, 수수의 3종류를 대상으로 피검균은 대장균을 인위적으로 오염시켜 세척조건에 따른 효과를 조사하였다. 초기 원료에 비해 세척횟수를 증가하여도 세척에 의한 오염균 감소효과는 없는 것으로 나타났다. 세척수량도 원료대비 200%의 경우가 오염균 감소에 약간 영향을 미치었으나 큰 효과는 나타나지 않았다. 세척 수 온도를 찬물이 아닌 $40^{\circ}C$의 물로 세척 시 1 log 이상의 오염균 감소효과를 보았다. 세척방법 시 염수를 첨가한 세척수의 사용 시 5% 정도가 적당하였으며 염수 처리 시 2 log 내지 3 log 정도의 감소효과를 관찰 하였다. 그러나 염류의 사용은 짠맛을 최종제품에 주게 되므로 염류를 제거하기 위한 세척공정이 추가로 필요하게 되며 완전한 염류의 제거를 위해서는 많은 양의 세척수량이 추가로 필요하게 된다.