• Title/Summary/Keyword: Contamination concentration

Search Result 930, Processing Time 0.031 seconds

Investigation and Analysis of Soil Contamination at Industrial Site (산업공장 주변 토양오염도 조사 분석)

  • 정하익;김상근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.99-102
    • /
    • 2000
  • There has been a steady increase in contaminated ground at municipal and industrial site. In this study, investigation and analysis on soil contamination at industrial site was carried out. Testing contaminated soils were sampled at this site. As a result of this study, the concentration of soil was investigated, and measured concentration was compared with related concentration criteria.

  • PDF

Assessment of Soil Pollutant Distribution Characteristics and Heavy Metal Pollution in Korea (국내 토양오염물질 분포 특성 및 중금속 오염도 평가)

  • Lee, Jong Cheol;Kang, Min Woo;Choi, Gyu Hyuk;Oh, Se Jin;Kim, Dong Jin;Lee, Sang Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • BACKGROUND: Heavy metals discharged from various sources contaminate the soil and water and the residuals can persistently be accumulated. In this study, the concentration of soil heavy metals was assessed over the whole regions of Korea based on the contamination factor and the geoaccumulation index. METHODS AND RESULTS: The data of averaged concentrations of heavy metals and fluorine were collected from the Korean Statistical Information Service (KOSIS) and the research papers published. In order to classify the levels of heavy metal concentration, the contamination index, including the contamination factor and the geoaccumulation index, based on the relative ratio of the actual concentration of heavy metals in the soil to the background concentration was calculated. In addition, the distribution of heavy metals in soils was visualized by using the geographic information system (GIS). As a result, the Cd contamination in the soils was the most concerned. CONCLUSION(S): This study very roughly indicated the outline of heavy metal concentration over the whole regions of Korea. The change in heavy metals' concentration over the time should further be monitored and the larger data of heavy metal contamination are needed for better understanding in the future.

An Assessment of the Heavy Metal Contamination of Sediment in Main Stream and Tributaries of the Han River in the Vicinity of Seoul (서울시 인근의 한강 본류 및 지류에 대한 하상 저질의 중금속오염 평가)

  • 노수미;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.17-35
    • /
    • 1994
  • This study was performed to investigate and assess the heavy metal contamination of sediment in main stream and tributaries of the Han-river in the vicinity of Seoul. Sediment were sampled at eight locations of main stream and eighteen locations of tributaries in the spring, summer, and fall in 1993. Six heavy metals of Cd, Cu, Pb, Zn, Cr, and Hg, were assessed. For an assessment of heavy metal contamination in sediment, the assessment method of Hakanson was modified to estimate for Han-river, then classification method of Muller in sediment quality was applied. For an assessment of contamination in each heavy metal, Contamination factor C$_f^i$ which was defined the ratio of concentration of i heavy metal in investigated location to background concentration of i heavy metal in uncontaminated upper area was used. The sediment quality in each heavymetal was classified as follows if C$_f^i$<1, Class I for Non contamination, if 1 < C$_f^i$ < 3, Class II for Low contamination, if 3< C$_f^i$ <6, Class III for Moderate contamination, if 6< C$_f^i$ <12, Class IV for Considerable contamination, and if C$_f^i$ > 12, Class V for High contamination.(abbreviation)

  • PDF

A Numerical Prediction of Contamination Behavior in a Room under the Turbulent Flow and Pressure-Based Boundary Conditions (난류유동 압력경계조건을 가진 실내공간에서의 오염물질 거동에 관한 수치적 예측)

  • 이재헌;노홍구;김광영;오명도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1272-1281
    • /
    • 1990
  • A numerical study to predict the contamination behavior in a room being contaminated has been performed. The room with one inlet and three exits, which maintained same pressure at the ceiling, has been chosen as test model. Six sets of calculation have been performed, for one, two or three contamination sources of 1*10$^{-4}$ kg$_{c}$/s strength at two different velocities(0.2m/s, 20m/s). Numerical results show that the number the contamination concentration near the first source increased by every 20%-30% of the maximum concentration for each increase of the contamination source.e.

Studies on the Evaluation Method of Heavy Metal Contamination Degree in the Han River (한강 저질중의 중금속 오염도 평가 방법에 관한 연구)

  • 어수미;박성배
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.47-57
    • /
    • 1992
  • This study was performed to evaluate contamination degree of heavy metals in sediments of Han River, compared with other nation's evaluation method. The results were as follows 1. The contamination Ratio calculation method by heavy metal concentration in differnt fraction size has a limitation to apply to all of the areas of Han river because of its characteristics of sediment. As a result, this method applied to only 4 areas of Pal Dang, Wang Sook Chon, Uk Chon, and Bul Kwang Chon, and Contmination Ratio of heavy metals in those areas were relatively low of below 3. So it's considered that those areas have less contaminated from anthropogenic contaminants. 2. The Contamination Ratio calculation method by heavy metal concentration in different areasthat of upper area to be background level-has a limitation also to apply to Han river. But it is considered that this method was relatively suitable to apply, so it should be prepared evaluation standand method for them. Contamination ratio from background level as Pal Dang area were most high in An Yang Chon. So it must be prepared purification and control measure at An Yang Chon.

  • PDF

Contamination Characteristics of Open Dumped Wastes at Land Developing Site (단지개발 지구내에 불법매립된 폐기물의 오염특성 분석)

  • 정하익;김상근;이용수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.415-418
    • /
    • 2000
  • There has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation on contaminant around unplaned waste landfill. In this study, investigation and test on contamination characteristics of wastes dumped at municipal site were carried out. Testing wastes were sampled at this site. Sampled wastes were divided into waste itself and soil to analysis the characteristics of waste and soil. As a result of this study, the concentration of soil and waste were investigated. And measured concentration were compared with related concentration criteria.

  • PDF

Practical Radiation Safety Control: (I) Application of Annual Limit on Intake and Derived Air Concentration (방사선안전관리 실무: (I) 연간섭취한도와 유도공기중농도의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.234-236
    • /
    • 2013
  • Some of radioactive contamination is unavoidable in the facilities using the unsealed radioactive material. The primary purpose of radioactive contamination control in the workplace with contamination concern is the effects from the potential intake of radioactive material into the body. This paper provides procedures to estimate the level of internal exposure for the worker based on the conservative assumptions and simple calculations. They consist of two processes; to calculate air concentration of radioactive material and annual intake by inhalation with contaminated air and to compare each of them to Derived Air Concentration and Annual Limit on Intake mentioned in the related notification. The procedures are applicable to make a decision on practical requirements for monitoring air contamination and internal exposure of worker as follows; needs for measurement of air contamination and internal exposure and acquisition of information on the design of the ventilation system.

A Study on Contamination Sensitivity and Condition Monitoring for a Pump (펌프의 오염 민감도와 성능 감시에 대한 연구)

  • 이재천
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.124-130
    • /
    • 1998
  • A mathematical model describing gear pump flow degradation in the presense of abrasive particles is presented. The model considers the operating parameters as Sommerfeld number, so that contamination sensitivity test results could be conversed to field application to predict contamination service life. A method to estimate the volumetric efficiency and the contamination level of a pump is proposed by measuring the temperature differences in the fluid. Test results show the validity of the theoretical establishments.

  • PDF

Investigation of Pollution of Polycyclic Aromatic Hydrocarbons and Heavy Metals in Soil near Railway Rails (철도레일 부근 토양의 다환방향족 탄화수소 및 중금속 오염도 조사)

  • Choi, Hyun-Kyung;Yoon, In-Ju;Shin, Tae-Cheon;Kim, Young-Hun
    • Journal of Environmental Science International
    • /
    • v.27 no.11
    • /
    • pp.947-956
    • /
    • 2018
  • Trains have been a major means of transport in Korea during these past decades. However, train facilities such as stations and repair shops are contaminated with organic and inorganic substances. There is a high probability of train facility contamination with polyaromatic hydrocarbons (PAHs). This study evaluated the PAH and heavy metal contamination of soil near railroads in the Kyungpook area. A total of 18 soil samples were collected from the railroads and analyzed for 16 PAHs and 6 heavy metal species. The contamination level of the top soil was found to be slightly higher than that of the subsoil for contamination with PAHs. The ratio of carcinogenic PAH concentration to the total PAH concentration was relatively high, with a maximum of 0.9. The toxicity equivalent (TEQ) of the PAHs were 500.6 ng/kg in the topsoil and 355.5 ng/kg in the subsoil. The ratio of low molecular PAHs (LPAHs) to high molecular PAHs (LPAHs) ranged from 6.7 to 29.5; this shows that contamination is primarily due to combustion of fuel rather than due to petroleum. The ratio of phenanthrene to anthracene and the ratio of fluoranthene to pyrene also show that contamination occurred due to combustion for transportation. The heavy metal contamination level was lower than the Korean standard, but higher than the background concentration; this indicates that the soil was affected by the operation of the railways.

Evaluation of Carryover Contamination on Autopipetting System (자동분주기의 이월오염 평가)

  • Lee, Hyun-Ju;Min, Gyung-Sun;Shin, Sun-Young;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.189-192
    • /
    • 2009
  • Purpose: Autopipetting system is an efficient automated equipment pipetting patient samples and reagents for rapid and accurate test. However, it can cause carryover between high concentration sample and low concentration sample. We evaluated carryover contamination of TECAN freedom Evo 100 autopipetting system. Materials and Method: We studied carryover contamination of $\alpha$-fetoprotein (AFP) and carcinoembryonic antigen (CEA) test on TECAN freedom Evo 100 autopipetting system. Very low concentration control samples were pipetted for comparison to the contaminated very low concentration samples. Then, The contaminated very low concentration samples were pipetted following the high concentration samples were pipetted alternately. The difference of low concentration samples represents carryover. The target value to decide carryover was 1ppm (parts per million). Results: For AFP, the mean values of the uncontaminated control samples and the contaminated samples were less than 0.6 IU/mL (the l imit of detection (LoD)). Carryover did not occur even though the high concentration sample which value was 650000 IU/mL. For CEA, the values of the low concentration control samples and the contaminated samples were less than 0.2 ng/mL (LoD). Carryover did not occur even though the high concentration sample which value was 65,000 ng/mL. Conclusions: Sample carryover was not found on TECAN freedom Evo 100 autopipetting system for AFP, CEA. However, carryover is a potential problem with automated instruments and robotic pipetting systems. Therefore, Clinical laboratories must periodically verify carryover contamination for the accurate and confidential test results.

  • PDF