• 제목/요약/키워드: Contamination Test

검색결과 642건 처리시간 0.031초

CD-ROM 드라이브의 대물렌즈 입자오염이 레이저 다이오드 파워와 포토 다이오드 RF 신호에 미치는 영향 (Effect of Particle Contamination of Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RE Signal)

  • 배양일;이재호;황정호
    • 대한기계학회논문집B
    • /
    • 제28권1호
    • /
    • pp.66-71
    • /
    • 2004
  • Airborne contaminant particles are intruded into optical disk drive(ODD) due to the flow caused by disk rotation and can be adhered to objective lens, which causes read/write errors. Such a phenomenon can be a serious problem for high-density storage devices. The purpose of this paper is to understand the effect of particle contamination of objective lens in a CD-ROM drive on laser diode power and photo diode RF signal. The measurements of laser power and readout RF signal were carried out by using a laser power meter and a time interval analyzer, respectively. The parameters for estimating a readout-signal' distortion were its jitter and amplitude. Alumina(Al$_2$O$_3$) particles were used as test dust particles. The results show that the failure for data access happened as the degree of lens contamination was greater than 20%.

대장암수술 시 장갑교환의 효과 (The Effect of Glove Changing during Surgery for Colon Cancer)

  • 박은지;함은미
    • 성인간호학회지
    • /
    • 제26권1호
    • /
    • pp.98-106
    • /
    • 2014
  • Purpose: The purpose of this study was to explore the effect of glove changing during surgery for colon cancer on reducing the degree of contamination of surgical gloves. Methods: The randomized posttest control group design was used. Total 72 surgeries of colon cancer in the K University Hospital in Seoul performed by the team of A-Surgeon and B-Scrub nurse were randomly assigned to one of the three groups. Glove changing with single-gloved state was implemented in the Experimental Group I and outer glove changing with double-gloved state was executed in the Experimental Group II. Single-gloved state was carried in the Control Group. Following the surgical procedure, specimens for bacterial culture were collected the from scrub nurse's gloves to compare the degree of contamination among the three groups. Data were analyzed with One-way ANOVA and the Scheff$\acute{e}$'s multiple comparison test. Results: The degrees of contamination of the Experimental Group I and II were significantly lower than that of the Control Group. There was no significant difference between Experimental Group I and II. Conclusion: Glove changing during surgery with either single or double-gloved state is effective in reducing the degree of contamination of surgical gloves, therefore these methods should be utilized in clinical practice.

방부살균제에 의한 유화형화장품에서의 Staplylococcus aureus의 성장억제 (The Growth Inhibition of Staplylococcus aureus in Emulsion Type Cosmetics with Antiseptics)

  • 류미숙;김장규;원성호;김남기
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.22-29
    • /
    • 1992
  • Emulsion-type cometics contain many kinds of carbon and energy source i.e., vegetable oil, mineral oil and carbohydrate etc., those can be used as nutrients and caused contamination by microbials. Thereby we have to keep cosmetics from the possibility of contamination by microbials. From this viewpoint, the purpose of this study is to get the data necessary not only to prevent dermatopathia occurred by microbials but also to sustain the quality. In this experiment, we observed how many Staphylococcus aureus were grown in the prepared cosmetics with or without antiseptics so as to prevent contamination. When the contamination proceed, the stability of phase was disturbed and creaming phenomina was happened with some discoloration and bad smell. About 40 days after, the pH was changed from 7.6 to 6.5 and the refractive index of cosmetic raw materials were changed from 1.4415 to 1.4490(water : oil=70:30). By adding antiseptics Into prepared cosmetics, the number of Staphylococcus aureus with challenge test method were decreased to 7$\times$103 cell/ml. For the antibacterial effect against Staphylococcus aureus, p-hydroxy benzoic acid propyl ester in phosphoric acid buffer solution was the best.

  • PDF

Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions

  • Mostafavi, Azam Sadat;Memarian, Maryam;Seddigh, Mohammad Ali
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.65-70
    • /
    • 2021
  • Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with one-way ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.

디이젤 오염토 수세시 초음파가 세척률 증가에 미치는 영향에 관한 연구 (Enhancement of Soil Flushing Method by Ultrasonic Radiation on Diesel Contaminated Soils)

  • 김영욱;김지형;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.401-406
    • /
    • 2000
  • Spilling of petroleum hydrocarbons such as gasoline, motor oils, and diesel fuel from underground storage tanks (USTs) is a major source of contamination to ground water and soils. In response to the need of developing an effective and economical cleanup technique, this study investigates the effectiveness of using sonication to enhance the soil flushing method. The study involves laboratory testing, and the testing was conducted using a specially designed and fabricated device to determine the effect of sonication on contaminant removal. The sonication was applied at 20 kHz frequency under different power levels. Test soil was Joomoonjin Sand, and diesel fuel was used as a contaminant of soil flushing test. The results of the investigation show that sonication enhanced the contaminant removal from soils significantly, and the degree of enhancement varied with power levels of sonication. Based on the results of the study, it is concluded that the flushing method with sonication has a great potential to become an effective method for removing petroleum hydrocarbons from the contaminated ground.

  • PDF

염진해 오손도 자동측정장치 (Automatic Measuring Apparatus for Salt and Dust Contamination)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF

솔잎 추출물을 이용한 염색직물의 기능성에 관한 연구[1] (A Study on the Functionality of the Fabrics Dyed with Pine Needles Extract (1))

  • 박영희
    • 복식
    • /
    • 제56권2호
    • /
    • pp.147-154
    • /
    • 2006
  • In this study 1, the dyeability and sun protection characteristic of the fabrics dyed with pine needles extract was investigated. In the test of color difference, the surface color of all the dyed fabric of both cotton and silk came to light as greenish yellow. In the test of dyeing colorfastness, the colorfastness to sunlight of dyed cotton fabric was below 2nd grade and the one of dyed silk fabric was below 3rd grade. The colorfastness to laundry for the degree of discoloration showed a difference as to mordants, but the colorfastness to laundry for the degree of contamination was excellent as all the dyed fabrics were 4th-5th grade. The colorfastness to perspiration was excellent as the degree of discoloration was more than 3rd grade and the degree of contamination was more than 4th-5th grade. The colorfastness to rubbing showed the excellent result as all the dyed fabrics were 4th-5th grade. In the test of sun protection factor(SPF), the cotton and silk fabrics dyed with $FeSO_4{\cdot}7H_{2}O$ mordant showed very high sun protection characteristic as the SPF was each 36.1 and 42.5. In the test of sun protection rate for UV-A and UV-B, the cotton and silk fabrics dyed with $FeSO_4{\cdot}7H_{2}O$ mordant showed the very high sun protection rate of more than $90\%$.

Novel approach to predicting the release probability when applying the MARSSIM statistical test to a survey unit with a specific residual radioactivity distribution based on Monte Carlo simulation

  • Chun, Ga Hyun;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1606-1615
    • /
    • 2022
  • For investigating whether the MARSSIM nonparametric test has sufficient statistical power when a site has a specific contamination distribution before conducting a final status survey (FSS), a novel approach was proposed to predict the release probability of the site. Five distributions were assumed: lognormal distribution, normal distribution, maximum extreme value distribution, minimum extreme value distribution, and uniform distribution. Hypothetical radioactivity populations were generated for each distribution, and Sign tests were performed to predict the release probabilities after extracting samples using Monte Carlo simulations. The designed Type I error (0.01, 0.05, and 0.1) was always satisfied for all distributions, while the designed Type II error (0.01, 0.05, and 0.1) was not always met for the uniform, maximum extreme value, and lognormal distributions. Through detailed analyses for lognormal and normal distributions which are often found for contaminants in actual environmental or soil samples, it was found that a greater statistical power was obtained from survey units with normal distribution than with lognormal distribution. This study is expected to contribute to achieving the designed decision error when the contamination distribution of a survey unit is identified, by predicting whether the survey unit passes the statistical test before undertaking the FSS according to MARSSIM.

자동분주기의 이월오염 평가 (Evaluation of Carryover Contamination on Autopipetting System)

  • 이현주;민경선;신선영;우재룡;이호영
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.189-192
    • /
    • 2009
  • 목적 : 자동분주기의 fixed probe pipetting system 은 검체 분주시 probe 내외부의 잔여물이 다음 pipetting cycle로 이월되어 처음 측정치가 차기 측정치의 결과에 영향을 미치는 이월오염(carryover contamination)을 발생시킬 수 있다. 이번 연구는 본원에 도입된 TECAN 사의 Freedom Evo 100 자동 분주기의 $\alpha$-fetoprotein (AFP)과 carcinoembryonic antigen (CEA) 검사 시 검체간 이월오염 발생을 확인하였다. 방법 : reference 가 되는 오염이 안 된 저농도 검체를 연속분주한다. 그런 후 고농도 검체를 분주한 다음 오염이 예상되는 저농도 검체를 연속 3회 분주하는 과정을 교대로 반복한다. 오염이 안 된 저농도 검체와 오염이 예상되는 저농도 검체값의 각 평균값을 서로 비교하여보고 각 저농도 검체값이 최소 검출 농도 이하인지 확인하고 만약 저농도 검체값간의 평균값이 차이가 있다면 그 차이가 1 ppm 이하의 carryover target 농도값 이하인지 확인한다. 결과 : AFP 약 650,000 IU/mL와 CEA 약 65,000 ng/mL의 고농도 검체에서는 오염이 안 된 저농도 검체값과 오염이 예상되는 저농도 검체값의 평균값 모두 각 검사의 최소 검출 농도값 이하로 이월오염이 나타나지 않았다. 결론 : 이번 연구에서 사용한 AFP와 CEA의 고농도 검체에서는 이월오염이 나타나지 않았지만 검사자는 검사결과 보고시 고농도 검체가 다음 환자 검사결과의 안정성에 영향을 줄 수 있음을 주시하고 이월오염을 확인하기위해 주기적인 장비관리와 이월오염 측정을 시행하여야한다.

  • PDF

비소 오염지역의 오염특성 비교조사 (Comparative Investigation of the Contamination characteristics on As contaminated Sites)

  • 유찬;윤성욱;백승환;박진철;이정훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1647-1654
    • /
    • 2008
  • The characteristics of arsenic(As) contamination were investigated on soils of 3 abandoned metal mine sites in Gangwon-do, Korea. Total forty nine soils were sampled to conduct standard methods(extraction by 1HCl), sequential extraction and column leaching test. Concentration of As extracted by 1N HCl was ordered as follows: A mine > B mine > C mine, and the concentration of arsenic in the soils of A mine was significantly greater than that at any other cases and all samples of A mine were exceeded the national regulation of $6mg \;kg^{-1}$. In the results of sequential extraction, the potential contamination risk for groundwater and plants was ordered as follows: C mine > B mine > A mine because the C mine showed the relatively greater mobility and bioavailability of fraction than any other mines. And, in colume test, concentration of As was ordered as follows: C mine > B mine > A mine, and it was expected that these results were connected with fraction characteristics of the mine sites. Therefore adequate leaching investigations should be used to simulate the effect of natural leaching conditions, and to predict both the potential mobility of metals to groundwater and their bioavailability to plants under natural conditions.

  • PDF