• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.041 seconds

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

Effects of Different Concentrations of Escherichia coli and Days of Preservation on Boar Sperm Quality

  • Chung, Ki-Hwa;Kim, In-Cheul;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.37 no.4
    • /
    • pp.213-217
    • /
    • 2013
  • The objective of this study was to investigate the effect of bacterial contamination on elapsed time after preservation on boar semen. Known numbers of Escherichia coli (E. coli) were inoculated to freshly ejaculated semen and sperm parameters such as viability, motility, agglutination, acrosome integrity and hypo-osmotic swelling test were performed during 7 days of liquid preservation. Semen samples were prepared using antibiotic free BTS extender and 4 different levels of E. coli were treated to semen with following concentrations; 3,000, 5,000, 7,000, 10,000 CFU/ml of sperms. Semen samples were preserved at $17^{\circ}C$ for 7 days in semen storage until analyzed. Aliquots were subjected to measure the sperm viability, motility and agglutination using computer assisted sperm analysis (CASA) system, acrosome integrity was performed using chlortetracycline (CTC) staining method and hypo-osmotic swelling test was performed using hypotonic solution from day 1 (day of semen collection) to 7. Detrimental effects on sperm motility and viability were observed 3 days after preservation at the level of 5,000 CFU/ml (p<0.05). Percentage of sperm abnormality was higher (p<0.05) in over 5,000 CFU/ml groups. Sperm agglutination rate was also significantly higher (p<0.05) in groups of 5,000 and 7,000 CFU/ml. The rate of acrosome reacted sperm was higher as preservation time goes in all the samples but the pattern was clearly higher among E. coli contaminated groups (p<0.05). The sperm membrane integrity in terms of hypo-osmotic test, E. coli affects little compared to other sperm parameters. The deleterious effects observed due to the bacterial contamination in semen suggest that importance of hygiene protocol to minimize the bacterial contamination during semen collection and processing.

A study on the reduction of indoor radon contamination (실내 라돈의 오염량 감소에 관한 연구)

  • Kim, Chang-Kyun;Choi, Jong-Hak;Kang, Jeong-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.53-56
    • /
    • 2006
  • The purpose of the present study is to find ways to reduce the quantity of indoor radon contamination. The study was done from July, 2005 until December, 2005. It was found out that the easiest and most effective way to do that is to open the windows as often as possible and let the indoor air flow outside. When it is not possible to ventilate a room, the indoor radon contamination quantity can reduced by providing activated charcoal in the room. It has been proved that activated charcoal can absorb the room in the air. We need more activated charcoal in proportion to the size of the room. A further research is needed to investigate the amount of activated charcoal that will work most effectively.

  • PDF

Current Issues on the Oil UST Management and Future Directions for the Prevention of the Subsurface Contamination (현행 주유소 지하유류저장시설 관리의 문제점과 토양${\cdot}$지하수 오염 방지를 위한 개선방안 연구)

  • Kim Meejeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.62-73
    • /
    • 2004
  • The current status and problems of UST management in gas stations were reviewed, and suggestions were made for possible improvement of UST management. Regulations and programs relevant through the whole life cycle of the UST, such as construction, installation, operation, and disclosure are insufficient to prevent oil release. The UST requirements are less stringent compared to those of the U.S. and EU members. Current soil test does not seem to be practically effective in detecting soil contamination caused by oil release. The potential for subsurface contamination due to oil release from the UST is estimated from available data other than soil test results. Much higher following future directions and suggestions are made to improve current unsatisfactory UST management: Firstly, increasing the UST requirements - establishing more stringent standards for new UST facilities, and adding new regulatory requirements for existing UST facilities; secondly, replacing current soil test with the tank and piping tests; thirdly, reinforcing programs for supervising the tank construction and installation; fourthly, constructing a system in which independent gas stations can properly manage the USTs; and lastly, educating UST owners and operators, and constructing DB of UST facilities.

Epidemiologic Investigation to Identify the Cause of an Infant Methemoglobinemia (서울 S지역에서 발생한 영아 메트헤모글로빈혈증 1례의 원인구명을 위한 역학조사)

  • Kim, Young-Yeul;Choi, Bo-Youl;Park, Hang-Bae;Kim, Min-Young;Yeo, In-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.192-201
    • /
    • 1993
  • Epidemiologic investigation was conducted on January, 1993 in Seoul to identify the cause of an infant methemoglobinemia. Field investigation of the area of outbreak, survey of household and family members, analysis of ground water, and blood tests of involved family members were performed. Following results were obtained On analyzing the quality of the ground water on patient's household high levels of nitrate was found indicating contamination of water as the cause of a methemoglobinemia outbreak. On analysing the quality of the ground waters on seven other places within the neighborhood five were contaminated by nitrate in concentration that exceeded the permissible limit implying presence nearby source of contamination. Sources of contamination were thought to be originating from human waste in conventional bathroom facilities, chicken manure used in nearby orchards and plant fields or fertilizers. But the results of water analysis with presence of bacteria or E.coli, concentration of potassium, phosphate and the past history of diarrhea among family members, chicken manure suggested the most possible source of contamination. To evaluate the health status of members in the neighborhood past history was reviewed revealing no prior existence of patient with cyanosis and 65 people in the neighborhood had normal levels of methemoglobin concentration in their blood. Conclusively, the ground water on patient's household was contaminated with nitrate and despite provision of adequate water supply, family members of the patient along with their distrust in the water supply system had used ground water as their source of drinking water resulting of methemoglobinemia. Many suburban area of Seoul and country side thought to be having similar problems concerning contaminated ground water supply and dormant outbreak of patients as a result of the drinking of the contaminated water. Epidemiologic investigation and water analysis of ground waters are advised.

  • PDF

Contamination Level and Behavior of Heavy Metals in Stream Sediments Within the Watershed of Juam Reservoir (주암댐 집수유역 내 하상퇴적물의 중금속 오염현황 및 거동 특성)

  • 염승준;이평구;강민주;신성천;유연희
    • Economic and Environmental Geology
    • /
    • v.37 no.3
    • /
    • pp.311-324
    • /
    • 2004
  • We investigated the contamination and behavior of heavy metals in stream sediments within the watershed of Juam Reservoir. Many abandoned mines within the reservoir can act as a potential contaminant source for water quality. Heavy metal concentrations (Cr, Cu, Ni, Pb and Zn) in stream sediments from watershed are very low, indicating that content of heavy metals in the sediments probably do not affect the water quality in Juam Reservoir. However Pb concentration in the stream sediments increases downward streams, suggesting the possible diffusion of Pb contamination. According to the leaching ratio for stream sediments at a strong acidic condition in the abandoned mine areas, the relative mobility for metals decreases in the order of Pb>Zn=Cu>Ni>Cr, indicating that Pb can have a bad effect upon the water quality in Jum Reservoir. Moreover, if contaminated sediment is placed in the bottom of reservoir (i.e., reducing condition), the relative mobility of Pb is the highest, indicating that Pb in the bottom sediments can be leached to water at interface between water and sediment with changing in physicochemical conditions.

PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System (수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서)

  • Han, Seung Heon;Kim, Tae Un;Jung, Haeng Yun;Ki, Hyun Chul;Kim, Doo Gun;Kim, Seon Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.

Contamination Source Assessment of Groundwater Nitrate in a Complex Terrain (복잡한 지형에서 발생하는 지하수의 질산태 질소 오염원 평가)

  • Han, Gwang-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • Classification of land uses and analysis of nitrogen isotope fractionation in groundwater nitrate were carried out to examine its contamination sources in Jeju province. ${\delta}^{15}N$ values of urea (hydrolyzed with urease), ammonium sulfate, compost, water from septic tank were -1.7, -5.8, +14.1, and +24.0‰, respectively. Urea, when it was directly distillated, showed -16.5‰. Based on these ${\delta}^{15}N$ values, sources of nitrate could be classified as originated from chemical fertilizers with ${\delta}^{15}N$ values below +5‰ and as from animal manure or municipal waste with ${\delta}^{15}N$ values over +10‰. Results of ${\delta}^{15}N$ analysis of 33 wells showed that most wells had the chemical fertilizers as their dominant contamination source. However, some wells were contaminated by other sources: animal wastes or municipal wastes. Some wells were also contaminated by the combined sources of nitrate. It was also demonstrated that ${\delta}^{15}N$ analysis could be a useful tool even in the case where no apparent contamination source is found.

Regional-Scale Evaluation of Groundwater Susceptibility to Nitrate Contamination Based on Soil Survey Information (토양정보를 이용한 광역 지하수의 질산태 질소 오염 민감도 분포 분석)

  • Han, Gwang-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.1
    • /
    • pp.37-45
    • /
    • 2009
  • Susceptibility assessment of groundwater contamination is a useful tool for many aspects of regional and local groundwater resources planning and management. It can be used to direct regulatory, monitoring, educational, and policy-making efforts to highly vulnerable areas. In this study, a semi process-based was proposed to evaluate relative susceptibilities to groundwater contamination by nitrate on a regional scale. Numerical simulation based on data from each soil series was done to model water flow within soil profiles that were related to groundwater contamination by nitrate. Relative vulnerability indices for each soil series were produced by manipulation of amount of leaching flux, amount of average water storage in a soil profile, and amount of average water storage change. These indices were designed to convey the trend of leaching flux and to maximize spatial resolution. The resulting vulnerability distribution map was used to locate highly vulnerable sites easily with an appropriate grouping the indices, and was then compared with those from groundwater nitrate concentrations monitored. An excellent agreement was obtained across nitrate concentrations from the highly vulnerable regions and those from the low to stable regions.

Influence of Plasma Corrosion Resistance of Y2O3 Coated Parts by Cleaning Process (세정공정에 따른 Y2O3 코팅부품의 내플라즈마성 영향)

  • Kim, Minjoong;Shin, Jae-Soo;Yun, Ju-Young
    • Journal of Surface Science and Engineering
    • /
    • v.54 no.6
    • /
    • pp.365-370
    • /
    • 2021
  • In this research, we proceeded with research on plasma resistance of the cleaning process of APS(Atmospheric Plasma Spray)-Y2O3 coated parts used for semiconductor and display plasma process equipment. CF4, O2, and Ar mixed gas were used for the plasma environment, and respective alconox, surfactant, and piranha solution was used for the cleaning process. After APS-Y2O3 was exposed to CF4 plasma, the surface changed from Y2O3 to YF3 and a large amount of carbon was deposited. For this reason, the plasma corrosion resistance was lowered and contamination particles were generated. We performed a cleaning process to remove the defect-inducing surface YF3 layer and carbon layer. Among three cleaning solutions, the piranha cleaning process had the highest detergency and the alconox cleaning process had the lowest detergency. Such results could be confirmed through the etching amount, morphology, composition, and accumulated contamination particle analysis results. Piranha cleaning process showed the highest detergency, but due to the very large thickness reduction, the base metal was exposed and a large number of contaminated particles were generated. In contrast, the surfactant cleaning process exhibit excellent properties in terms of surface detergency, etching amount, and accumulated contamination particle analysis.