A Study on the Verification and Improvement to Locate and Determine the Radioactive Contamination Using a Whole Body Counter (전신계측기를 이용한 원전종사자 방사성오염 위치확인과 내부방사능 측정개선에 관한 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Whole body counters (WBCs) are used to monitor radiation workers for internal contamination of radionuclides at domestic nuclear power plants (NPPs). A WBC is a scintillation detector using sodium iodide (NaI) and provides the identification of inhaled radionuclide and the measurement of its internal radioactivity in a short time. However, it is often possible to estimate external contamination as internal contamination due to radionuclides attached to the skin of radiation workers and this leads to an excessively conservative estimation of radioactive contamination. In this study, several experiments using a WBC and the Korean humanoid phantom were performed to suggest the more systematic method of discrimination between external and internal contamination. Furthermore, a WBC geometry experiment was conducted to suggest the optimal WBC geometry in consideration of deposited areas inside the body for dominant radionuclides at NPPs. The procedure of measurement and estimation of internal radioactivity for radiation workers at NPPs was improved on the basis of experimental results. Thus, it is expected to prevent from estimating internal exposure dose conservatively owing to the application of accurate whole body counting program to NPPs.

A Study on Bacterial Concentrations in Dental Offices (치과 진료실내의 세균오염도와 영향인자에 관한 연구)

  • Yun, Kyoung-Ok;Park, Hee-Jin;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.469-476
    • /
    • 2014
  • Objectives: The purpose of this study was to identify the stains causing infections in dental clinics by analyzing bacterial contamination, as well as to suggest improvements for infection control in dental clinics. Methods: In this study, a questionnaire survey of 47 dental hospitals and clinics located in Gyeonggi-do and Incheon, South Korea was administered from June 2013 to September 2013 and used to investigate the practice rates of infection control by dental hygienists and to analyze the bacterial contamination levels in dental offices. Results: In the studied institutions, the bacterial contamination levels of water lines were $20.9{\times}10^3$ colony forming units (CFU)/mL for three-way syringes, $12.7{\times}10^3CFU/mL$ for high-speed handpieces and $9.8{\times}10^3CFU/mL$ for gargling water. The bacterial contamination levels of surfaces were $44.9{\times}10^3CFU/mL$ in cuspidors, higher than in unit chairs ($2.9{\times}10^3CFU/mL$) and light handles ($6.7{\times}10^3CFU/mL$). The mean bacterial cell count of water lines and surfaces was relatively high in all establishments founded 11 years ago or more, and the mean bacterial cell count of waterline handpieces was $6.27{\times}10^3CFU/mL$ in establishments founded between one and five years ago, $11.16{\times}10^3CFU/mL$ six to ten years ago and $20.04{\times}10^3CFU/mL$ 11 years ago or more, which suggests that earlier foundation is associated with higher bacterial contamination levels with a statistical difference (p<0.01). Similarly, the mean bacterial cell count of cuspidors using water from water lines was also $70.16{\times}10^3CFU/mL$ in at least 11-year-old establishments, statistically significantly higher among in one- to five-year-old ($4.61{\times}10^3CFU/mL$) and six- to ten-year-old clinics ($47.89{\times}10^3CFU/mL$) (p<0.05). Conclusion: This study may be utilized to improve the bacterial contamination levels in dental offices by controlling the characteristics and environmental factors of dental offices that affect the microbial contamination of waterlines and surfaces in such institutions.

Evaluation of the Level of microbial Contamination in the Processing Company of Nuroong-ji (누룽지 생산시설에 대한 미생물학적 오염도 평가)

  • Do, Yu-No;Choi, Jeong-Sik;Jung, Yu-Kyung;Park, Ji-Hyun;Roh, Kyong-Hwan;Kim, Sung-Soo;Choi, Shin-Young;Lee, Kyoung-Yun;Han, Eui-Jeong
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.333-340
    • /
    • 2010
  • This study was conducted to evaluate the microbial contamination levels in the processing company of Nuroong-ji. Microbial contamination levels were examined for sanitary indication bacteria such as aerobic plate count, coliforms and fungi, and pathogenic bacteria such as Escherchia coli O157:H7, Salmonella spp., Staphylococcus aureus, and Listeria monocytogenes. Contamination levels were detected differently according to handling materials and purposing work-space. The equipments and raw materials were not seriously contaminated but there were necessary to attend the cross-contamination. A high contamination level was detected at the process where the interference of the employees was relatively higher than the other process. Standardization of the roasting process (l20~$170^{\circ}C$, about 10 min) could be necessary to control the microbial organism effectively on Nuroong-ji manufacturing process. At small/medium size foodstuff manufacturers, it is the most important to improve the recognition level of individual hygiene but also expand a hygiene facility.

Prevention of Microbial Contamination Through Monitoring of the Harvesting, Sorting, and Distribution Stages of Fresh Hot Pepper (신선 고추의 수확, 선별 및 유통 단계에서의 미생물 모니터링 및 미생물 오염 저감화 방법 모색)

  • Kim, Sol-A;Lee, Jeong-Eun;Park, Hyun-Jin;Lee, Sang-Dae;Moon, Hyo-Yeong;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.1
    • /
    • pp.60-67
    • /
    • 2020
  • This study determined the microbial contamination levels of hot pepper at harvest, sorting, and distribution stages to suggest a way of reducing the microbial contamination of hot peppers by changing work gloves used throughout these processes. According to the monitoring results, the contamination levels of total aerobic bacteria (TAB) were found in the following order: soil (5.3±0.9 log CFU/g), hot pepper (4.2±0.9 log CFU/g), gloves (4.2±0.6 log CFU/g), baskets (4.1±0.7 log CFU/ g), clippers (3.9±0.6 log CFU/ g) and water (3.2±1.1 log CFU/g) at harvest stage. The contamination level of coliforms were found in the following order: soil (2.2±0.9 log CFU/g), hot pepper (2.2±0.3 log CFU/g), gloves (2.1±0.6 log CFU/g), clippers (2.0±0.21 log CFU/ g) and baskets (1.9±1.1 log CFU/ g) at harvest stage. TAB on hot pepper at the harvest stage was reduced from 4.2±0.9 log CFU/g to cold storage 3.8±0.2 log CFU/g and room temperature storage 2.6±0.3 log CFU/g, respectively. By the replacement of work gloves and lower distribution temperature, TAB levels of the peppers were significantly reduced compared to those without replacement and distributed at room temperature. In addition, the utilization of plasma was effective on reducing microbial contamination of hot pepper. These results demonstrated that appropriate replacement of gloves at the harvest stages, using plasma in the distribution stage, and refrigerated distribution conditions, which are simple and easy to practice in the field, are effective to reduce microbial contamination on hot peppers.

SHEAR BOND STRENGTH OF SELF-ETCHING PRIMER SYSTEMS TO CONTAMINATED DENTIN IN PRIMARY TEETH (오염된 유치 상아질에 대한 자가 부식 프라이머의 결합강도에 관한 연구)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eup
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.107-114
    • /
    • 2002
  • The purpose of this study was to determine and compare the shear bond strength of two self-etching primer systems to primary teeth contaminated with saliva and blood. Clearfil SE Bond and AQ Bond were evaluated. One hundred specimens were made by seventy-five deciduous teeth(fifty anterior and twenty-five posterior teeth) and divided randomly into ten groups. Small flat dentinal surfaces were prepared by grinding the buccal, lingual and labial areas. Specific surface treatments were applied to each group: (1) a self-etching primer application(control group), (2) saliva contamination followed by primer(Group I), (3) primer curing followed by saliva contamination (Group II), (4) blood contamination followed by primer(Group III), (5) primer curing followed by blood contamination(Group IV). After bonding of composite resin(Z100, 3M, USA) to contaminated sample surfaces and thermocycling(1,000 cycles), shear bond strengths were measured using Universal Testing Machine(Zwick Z020, Zwick Co., Germany). The results were as follows; 1. Group I showed lower shear bond strength than control group but no statistically significant difference was found(P>0.05). 2. Group II and blood contamination group(Group III & IV) showed significantly lower shear bond strength than control group(P<0.01). 3. The shear bond strength of Clearfil SE Bond was significantly higher than that of AQ Bond(P<0.05).

  • PDF

A Study of Dermal and Ocular Exposure to Isocyanate-Based Paints in Crash Repair Workshops (차량수리업에서 사용하는 이소시안계 페인트에 의한 피부와 눈의 노출에 관한 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo;Tkaczuk, Michael
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.72-78
    • /
    • 2009
  • Exposure to HDI(hexamethylene di-isocyanate) commonly used in vehicle crash repair workshops remains a leading cause of occupational asthma. Although skin and eye contamination are considered as absorption routes, there are no occupational exposure standards for skin and ocular exposure. This is the reason why there are more empirical data should be provided. Therefore this study was to determine contamination levels of HDI on the skin, eyes, work surfaces, respirators and eye protectors. There was evidence of contamination on a variety of work surfaces, for example, door handles, bench top and spray gun, etc. A high proportion(47~80%) of skin wipe samples from neck, forehead, back hand, palm and wrist was positive for HDI contamination, even though spray time was relatively brief. The contamination levels from spraying inside spray booth were generally higher than outside booth due to poor work practices and inappropriate personal protective use like safety gloves. Apprentices had higher exposure levels than the qualified painters, likely due to lack of the recognition of safety and hygiene. The extent of contamination inside the PPE might provide an indication of the potential for respiratory & skin exposure and ocular exposure. Eye fluid samples from 4 out of 14 workers had the positive detection of HDI contamination, due to poor work practices like no or inappropriate eye protection. Considering the potential for dermal & ocular exposure to contribute to possible health symptoms including respiratory sensitization, the empirical data point to a need for improving work practices and appropriate PPE selection, use and maintenance.

Effect of Saliva Contamination Stage and Different Decontamination Procedures on Bonding Strength of Resin-Modified Glass Ionomer (레진강화형 글라스아이오노머의 초기 결합력과 타액오염 제거의 상관관계)

  • Go, Hanho;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.158-164
    • /
    • 2019
  • The purpose of this study was to compare the bond strength of resin-modified glass ionomer (RMGI) to dentin with saliva contamination at different stages and using different decontamination procedures. Extracted human permanent molars were embedded onto acrylic resin with the dentin surface exposed. Group I was a control group that was conditioned with polyacrylic acid (PAA). Groups II and III were contaminated with saliva before PAA conditioning and Groups IV, V, and VI were contaminated with saliva after PAA conditioning. After saliva contamination, Groups II and IV were dried, Groups III and V were rinsed and dried, and Group VI was additionally conditioned with PAA. After surface treatment, the dentin specimens were filled with RMGI. Group I showed significantly higher bond strength than the other groups. Group VI showed a significantly higher bond strength than the other saliva contaminated groups. However, there were no significant differences in the failure mode between the different groups. Saliva contamination impaired the bond strength of RMGI to dentin, regardless of when the saliva contamination occurred. Decontamination with washing and drying could not improve the shear bond strength of RMGIC. When saliva contamination occurred after PAA conditioning, additional PAA conditioning improved the shear bond strength.

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.

Analysis of contamination characteristics of filter cloth in filter press by repeated dehydration of organic sludge and evaluation of ultrasonic cleaning application (유기성 슬러지 반복 탈수에 의한 필터프레스 여과포 오염 특성 분석 및 초음파 세척 적용 평가)

  • Eunju Kim;Cheol-Jin Jeong;Kyung Woo Kim;Tae Gyu Song;Seong Kuk Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.2
    • /
    • pp.15-25
    • /
    • 2024
  • In this study, the regeneration effect of pressurized water and ultrasonic cleaning was investigated for contaminated filter cloth from the sewage sludge filter press process. For this purpose, contaminated filter cloth was collected from a 3-ton sewage sludge hydrothermal carbon treatment filter press. First, the contamination characteristics were analyzed. According to the location of the filter cloth, air permeability and unit mass were measured, and compared with the values of a new filter cloth. Next, the results were mapped over the entire area to evaluate the contamination characteristics. Finally, pressure cleaning at 3 bar and ultrasound at frequencies of 34, 76, 120, and 168 kHz were performed on the contaminated filter cloth. In addition, the cleaning efficiency was evaluated by 3 levels of contamination degree. As a result, pore contamination occurred mainly at the bottom and both sides of the filter cloth, where the filter material was continuously injected and compressed. Surface contamination appeared evenly over the entire area. As a result of washing, air permeability increased by 1.3-3.1%p and contaminant removal was by 2.7-4.4% under pressure. In ultrasonic cleaning, air permeability increased by 12.5-61.5%p and contaminants were removed by 2.7-29.2%. In ultrasonic cleaning the lower the frequency, the higher air permeability and contaminant removal rate. Also, The higher pore contamination level, the better the air permeability improvement and contaminant removal.

Fecal Contamination Associated with Local Reclamation Activity in the Han River Estuary

  • Hyun, Jung-Ho;Ju, Se-Jong;Harvey, H.R.
    • Journal of the korean society of oceanography
    • /
    • v.37 no.4
    • /
    • pp.224-231
    • /
    • 2002
  • Vertical distributions of coprostanol (5$\beta$-cholestan-3$\beta$-ol) and other sterols were investigated in the intertidal sediment of Shinbul island in the Han River estuary to estimate the short-term variations of fecal contamination in association with reclamation activity which caused a construction of tidal barrier and emigration of residents from the island. Quantitative contributions of coprostanol in total sterol (9.87-15.84%) and in total organic carbon (82.0-157.7 $\mu\textrm{g}$ g$^{-1}$ OC) implied that a substantial amount of organic matter associated with fecal pollutants was introduced into the sediment. The highest contribution of coprostanol to organic carbon that was observed between 0.3-0.9 cm depth seemed to be associated with increased human activities for the reclamation project of the island. The ratio of coprostanol to organic carbon decreased within 0.3 cm depth, which indicated decreased fecal contamination after the emigration of residents from the island. The results suggested that measurement of coprostanol could relevantly reflect short-term fluctuation of fecal contamination in the sediment of the Han River estuary.