• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.073 seconds

The Effect on the Microroughness of Si Substrate by Metallic Impurity Ca (금속 불순물 Ca이 Si 기판의 표면 미세 거칠기에 미치는 영향)

  • Choe, Hyeong-Seok;Jeon, Hyeong-Tak
    • Korean Journal of Materials Research
    • /
    • v.9 no.5
    • /
    • pp.491-495
    • /
    • 1999
  • In this study, we focus on Ca contaminant which affects on the roughness Si substrate after thermal process. The initial Si substrates were contaminated intentionally by using a standard Ca solution. The contamination levels of Ca impurity were measured by TXRF and the chemical composition of that was analyzed by AES. Then we gre the thermal oxide to investigate the effect of Ca contaminants. The microroughness of the Si surface, the thermal oxide surface, and the surface after removing the thermal oxide were measured to examine the electrical characteristics. The initial substrates that were contaminated with the standard solution of Ca exhibited the contamination levels of 10\ulcorner~10\ulcorneratoms/$\textrm{cm}^2$ which was measured by TXRF. The Ca contaminants were detected by AES and exhibited the peaks of Ca, SI, C and O.After intentional contamination, the surface microroughness of this initial substrate was increased from $1.5\AA$ to 4$\AA$ as contamination levels became higher. The microroughness of the thermal oxide surfaces of both contaminated and bare Si substrates exhibits similar values. But the microroughness of the contaminated$ Si/SiO_2$ interface was increased as contamination increased. The thermal oxide of contaminated substrate exhibited the small minority carrier diffusion length, low breakdown voltage, and slightly high leakage current.

  • PDF

Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition (환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술)

  • Park, Jae-Jun;Choi, In-Hyuk;Kim, Jeong-Boo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

The role of domestic tap water in Acanthamoeba contamination in contact lens storage cases in Korea

  • JEONG Hae Jin;YU Hak Sun
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.2 s.134
    • /
    • pp.47-50
    • /
    • 2005
  • A survey was carried out from August to December 2004 in Pusan, Korea to document the presence of free-living amoeba (FLA), including the genus Acanthamoeba, in both contact lens storage cases and domestic tap water. Acanthamoeba was isolated from $5(4.2\%)$ in 120 contact lens storage cases. Four house tap water samples from residents, whose contact lens storage cases had been contaminated by Acanthamoeba, were also found to be contaminated with Acanthamoeba. Therefore, the contamination rate of FLA and Acanthamoeba in domestic tap water was investigated in order to examine the role of domestic tap water in Acanthamoeba contamination of contact lens storage cases. FLA and Acanthamoeba were identified in $97(46.8\%)\;and\;16(7.7\%)$ of the 207 domestic tap water samples, respectively. There were no significant differences between the contamination rates of FLA in tap water according to the filtration plant of origin. No FLA was detected in the tap water directly supplied by the water purification plants. Water storage tanks appear to promote FLA colonization, including Acanthamoeba, in domestic tap water. This increases the risk of Acanthamoeba contamination in contact lens storage cases as well as increasing the risk of Acanthamoeba keratitis.

Soil Pollution Characteristics of Metallic Mine Area according to Extraction Methods (추출방법에 따른 금속광산 주변의 토양오염 특성)

  • Yang, Jung-Seok;Lee, Ju-Young;Park, Young-Tae;Baek, Ki-Tae;Choi, Jae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.3
    • /
    • pp.1-6
    • /
    • 2010
  • This study investigated the change of metal contamination levels according to amendment of enforcement regulation of the Soil Environmental Conservation Act in Korea. As an analytical result of 87 samples in abandoned metallic mine area, the extracted amount of As, Pb and Cu with aqua regia was 4.3~29.6 times higher than that with hydrochloric acid extraction and the number of samples, which contamination levels were found to exceed soil contamination standards, was also increased. On the other hand, in case of Cd, Zn, and Ni, the number of samples, which contamination levels were found to exceed soil contamination standards, was decreased or similar. These results can be used as a preliminary material in comparison between the soil pollution data accumulated previously and the data obtained by the revised standard method for the examination of soil pollution.

Geophysical Applications on the Soil-contamination Mapping and Detection of Buried Mine Tailings in the Abandoned Mine Area (폐광산의 토양오염영역 및 폐기된 광미의 탐지)

  • Lee, Sang Kyu;Hwang, Se Ho;Lee, Tai Sup
    • Economic and Environmental Geology
    • /
    • v.30 no.4
    • /
    • pp.371-377
    • /
    • 1997
  • This paper presents the geophysical applications to the environmenml problem in an abandoned mine area. We would like to focus our attention on the mapping of the soil contamination and the detection of the buried mine tailings. For mapping the soil contamination. measurements of both in-situ magnetic susceptibility (k) and terrain conductivity were carried out. In-situ magnetic susceptibilities of the contaminated soil due to the acid mine drainage show higher values than those of the uncontaminated area. However. those data do not show the correlation with the degree of the soil contamination observed on the surface. The least-squares fitted formula obtained with the measured insitu magnetic susceptibilities is $k=4.8207{\times}W^{0.6332}$, where W is the $Fe^{+2}$ weight percentage. This weight gives most effect to magnetic susceptibility of the soil. Lateral variations of the soil contamination in the shallow subsurface can be detected by the electrical conductivity distributions from EM induction survey. TDIP (Time Domain Induced Polarization) and EM induction surveys were conducted to detect the buried mine tailings. From the results of TDIP, the spatial zone, which shows high chargeability-low resistivity, is interpreted as the buried mine tailings. Therefore, it is concluded that it is possible to discriminate the spatial zone from the uncontaminated ground.

  • PDF

Contamination patterns of Listeria spp. in pork processing plants using random amplified polymorphic DNA (RAPD를 이용한 돈육 가공장의 Listeria 오염양상 분석)

  • Ha, Sung-Yeol;Choi, Weon-Sang;Bahk, Gyung-Jin;Hong, Chong-Hae
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.3
    • /
    • pp.359-367
    • /
    • 2005
  • This study was carried out to understand the contamination patterns of Listeria in pork processing plants. A total of 402 samples were collected from carcass, pork during processing, surfaces of equipment and environment, and 238 isolates of Listeria species were identified. L. innocua was found in 64.7% of the isolates, L. monocytogenes in 33.2%, and L. welshimeri in 2.1%. Random amplified polymorphic DNA (RAPD) analysis performed to investigate the origin and routes of Listeria contamination, showed 21 composite types of L. monocytogenes and 26 composite types of L. innocua. It was confirmed that Listeria contamination begins with contaminated incoming carcass and ever-present contaminants in the processing environments. The persistence and dissemination of the same strain of L. monocytogenes and L. innocua throughout the processing line revealed that the sanitation standard operating procedure should be implemented to minimize the risk of colonization in the workplace. Molecular subtyping of L. innocua allowed us to tracing the possibility of cross-contamination during processing.

MICROBIOLOGICAL QUALITY OF BRAZILIAN LIPSTICKS AFTER NORMAL USE BY CONSUMERS

  • D.M.M. Pedroso;G.R. Dias;Gesztesi, J-L
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.524-526
    • /
    • 2003
  • Lipsticks are cosmetics which do not contain water and are usually preserved with parabens. When submitted to the Challenge Test, theses products did not reach the CTFA criteria, which means that microbiological contamination could occur before the end of its shelf life. The aim of this study was to evaluate the contamination level of 130 lipsticks after its use. Microorganisms were isolated from 14,6 % of the samples. However, only in two samples (1,5%) the contamination level exceeded the 100 CFU/g level, which means that, although the preservative system was not efficient to eliminate bacteria, the lack of free water was enough to prevent the microbial development. Total bacteria and fungi were determined by conventional methodology, according to CTFA Microbiological Guidelines. The microbes were then isolated and characterized as normal skin flora microorganisms. This suggest that products were contaminated by the constant application of lipsticks by consumers. This could lead to cross contamination when the same product is shared by several people. Extra care should be taken into account when this type of products are available to be tested by several consumers in demonstration displays.

  • PDF

The Effects of Organic Contamination and Surface Roughness on Cylindrical Capacitors of DRAM during Wet Cleaning Process

  • Ahn, Young-Ki;Ahn, Duk-Min;Yang, Ji-Chul;Kulkarni, Atul;Choi, Hoo-Mi;Kim, Tae-Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.3
    • /
    • pp.15-19
    • /
    • 2011
  • The performance of the DRAM is strongly dependent on the purity and surface roughness of the TIT (TiN/Insulator/ TiN) capacitor electrodes. Hence, in the present study, we evaluate the effects of organic contamination and change of surface roughness on the cylindrical TIT capacitor electrodes during the wet cleaning process by various analytical techniques such as TDMS, AFM, XRD and V-SEM. Once the sacrificial oxide and PR (Photo Resist) are removed by HF, the organic contamination and surface oxide films on the bottom Ti/TiN electrode become visible. With prolonged HF process, the surface roughness of the electrode is increased, whereas the amount of oxidized Ti/TiN is reduced due to the HF chemicals. In the 80nm DRAM device fabrication, the organic contamination of the cylindrical TIT capacitor may cause defects like SBD (Storage node Bridge Defect). The SBD fail bit portion is increased as the surface roughness is increased by HF chemicals reactions.

Microbiological Contamination of Fresh-Red Pepper and Packaged-Red Pepper Powder in South Korea

  • Jeong, A-Ram;Jo, Mi-Jin;Koo, Min-Seon;Oh, Se-Wook;Ku, Kyung-Hyung;Park, Jae-Bok;Kim, Hyun-Jung
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.3
    • /
    • pp.233-238
    • /
    • 2010
  • The aim of this study was to determine microbiological contamination of fresh-red pepper and packaged-red pepper powder commercially available in South Korea. Thirty-seven fresh-red peppers were collected from 5 farms and 31 packaged-red pepper powders were purchased from retail markets in South Korea. Foodborne pathogens (Escherichia coli, Salmonella spp., Listeria monocytogenes, Staphylococcus aureus and Bacillus cereus), total viable counts, Enterobacteriaceae, coliforms, yeast and mold, and Aspergillus flavus were determined. Detection percentage of contamination of Bacillus cereus in fresh-red pepper was 8.1%, which was lower than the 39% of detection rate in packaged-red pepper powder. The contamination level of Bacillus cereus was 1~3 log CFU/g in packaged-red pepper powder. Escherichia coli was detected in 5.4% of fresh-red pepper samples and was not detected in packaged-red pepper powder. Enterobacteriaceae and coliforms were detected in both of fresh-red pepper and packaged-red pepper powders. Foodborne pathogens, except Bacillus cereus and Escherichia coli, were not detected.

A Fundamental Investigation to Develope a Automatic Apparatus for Contamination Measurement (오손도 자동측정장치 개발을 위한 기초연구)

  • 최남호;한상옥
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.74-82
    • /
    • 2001
  • To reduce the maintenance expense and the possibility of electric outage and/or accident, which causes the decrease in stability and reliability of transmission/distribution line, most of all, accurate measurement for the degree of contamination should be preceded. But the conventional method (brush wiping method), which is recommended in IEC 60815, has sow significant problem in the aspect of man power, expense, error, and so forth. In this investigation, we purpose the development of a new type automatic measuring apparatus, which could measure the degree of contamination on the surface of insulator in outdoor condition. To design and evaluate the apparatus, a FLUX 2D is used, and various laboratory tests, artificial contamination tests, were carried to proof the actual performance. With the result of these effort, we can get the meaningful conclusion to develope a new type automatic apparatus for contamination measurement.

  • PDF