• Title/Summary/Keyword: Contaminant particles

Search Result 60, Processing Time 0.036 seconds

Degradation of a Refractory Organic Contaminant by Photocatalytic Systems

  • Kim, Il-Kyu
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.133-139
    • /
    • 2014
  • In this research, the photocatalytic degradation of benzothiophene in $TiO_2$ aqueous suspension has been studied. $TiO_2$ photocatalysts are prepared by a sol-gel method. The dominant anatase-structure on $TiO_2$ particles is observed after calcining the $TiO_2$ gel at $500^{\circ}C$ for 1hr. Photocatalysts with various transition metals (Nd, Pd and Pt) loading are tested to evaluate the effect of transition metal impurities on photodegradation. The photocatalytic degradation in most cases follows first-order kinetics. The maximum photodegradation efficiency is obtained with $TiO_2$ dosage of 0.4g/L. The photodegradation efficiency with Pt-$TiO_2$ is higher than pure $TiO_2$ powder. The optimal content value of Pt is 0.5wt.%. Also we investigate the applicability of $H_2O_2$ to increase the efficiency of the $TiO_2$ photocatalytic degradation of benzothiophene. The optimal concentration of $H_2O_2$ is 0.05. The effect of pH is investigated; we obtain the maximum photodegradation efficiency at pH 9. Hydroxy-benzothiophenes and dihydroxy-benzothiophenes are identified as reaction intermediates. It is proposed that benzothiophene is oxidized by OH radical to sequentially form hydroxyl-benzothiophenes, dihydroxybenzothiophenes, and benzothiophenedione.

Behavior of contaminated liquid CO2 droplets in the deep sea

  • Nguyen, Thao;Hwang, Jin Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.257-257
    • /
    • 2015
  • Carbon Capture and Storage with ocean sequestration is being considered as one of the most effective option for reducing the $CO_2$ net flux from atmosphere nowadays. But it is still possible for $CO_2$ substance to leaks out from transport pipeline or from the under seabed storage sites and causing damage to ambient environment. The behavior of liquid $CO_2$ under droplet shape would be strongly affected by the presence of other contaminants such as $SO_2$ comes from processing processes. This presentation shows the behavior in the sea water of pure liquid $CO_2$ droplets as well as droplets that consist of $SO_2$ substances. The study uses computational fluid dynamic models in comparison with experimental data from other previous researchers. Droplet of liquid $CO_2$ is assumed to be released at several depths in deep ocean, with other environmental conditions are set up respectively. All calculations are conducted with many different ratio of contaminant $SO_2$ to provide fundamental data of those particles rising characteristics. The effect of contaminants on the behavior of $CO_2$ droplets would be clearly shown through the results of particle deformation, terminal rising velocity happen due to buoyancy force driving from the difference in density of $CO_2$ substance and ocean water around.

  • PDF

Development of Oil Flushing System with Microbubble Generator (마이크로 버블 발생장치와 결합된 오일 플러싱 장치 개발)

  • Hong, Sung-Ho;Lee, Kyung-Hee;Jeong, Nam-Wha
    • Tribology and Lubricants
    • /
    • v.38 no.3
    • /
    • pp.109-114
    • /
    • 2022
  • This paper reports the development of an oil flushing system combined with a microbubble generator. Oil flushing plays a crucial role in regulating the lubricant's performance during the lubricant replacement process. Moreover, harmful contaminants, such as sludge, wear particles, and rust, from piping systems or lubrication system can be removed by oil flushing. Oil flushing aims to increase the system's efficiency using a dedicated flushing oil, increasing of the supply pressure and generating a vortex. In addition, it helps the mechanical system or equipment achieve peak performance and reduces the potential for premature failure. However, the contaminant-removal applications of existing oil flushing system are limited. In this research, we aim to improve the performance of oil flushing system by incorporating a microbubble generator, which uses the venture effect to generate microbubbles and mixes them with lubricant. The microbubbles in the blended lubricant remove contaminants from the lubrication system more effectively. Structural mechanics and fluid dynamics are analyzed through fluid-structure interaction (FSI) analysis, and the numerical analysis results are used for the designing the system. The magnitude of the maximum stress is investigated based on the pressure results obtained by the CFD analysis; through the CFD analysis, the mixing ratio of air (bubble) and lubricant is evaluated using the volume of fluid (VOF) model according to the working conditions.

Autotrophic Perchlorate-Removal Using Elemental Sulfur Granules and Activated Sludge: Batch Test (원소 황 입자와 활성 슬러지를 이용한 독립영양방식의 퍼클로레이트 제거: 회분배양연구)

  • Han, Kyoung-Rim;Kang, Tae-Ho;Kang, Hyung-Chang;Kim, Kyung-Hun;Seo, Deuk-Hwa;Ahn, Yeong-Hee
    • Journal of Life Science
    • /
    • v.21 no.10
    • /
    • pp.1473-1480
    • /
    • 2011
  • Perchlorate ($ClO_4^-$) is a contaminant found in surface water and soil/ground water. Microbial removal of perchlorate is the method of choice since microorganisms can reduce perchlorate into harmless end-products. Such microorganisms require an electron donor to reduce perchlorate. Conventional perchlorate-removal techniques employ heterotrophic perchlorate-reducing bacteria that use organic compounds as electron donors to reduce perchlorate. Since continuous removal of perchlorate requires a continuous supply of organic compounds, heterotrophic perchlorate removal is an expensive process. Feasibility of autotrophic perchlorate-removal using elemental sulfur granules and activated sludge was examined in this study. Granular sulfur is relatively inexpensive and activated sludge is easily available from wastewater treatment plants. Batch tests showed that activated sludge microorganisms could successfully degrade perchlorate in the presence of granular sulfur as an electron donor. Perchlorate biodegradation was confirmed by molar yield of $Cl^-$ as the perchlorate was degraded. Scanning electron microscope revealed that rod-shaped microorganisms on the surface of sulfur particles were used for the autotrophic perchlorate-removal, suggesting that sulfur particles could serve as supporting media for the formation of biofilm as well. DGGE analyses revealed that microbial profile of the inoculum (activated sludge) was different from that of the biofilm sample obtained from enrichment culture that used sulfur particles for $ClO_4^-$-degradation.

The development of the Ionizer using clean room (청정환경용 정전기 제거장치 개발)

  • Jeong, Jong-Hyeog;Woo, Dong Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.603-608
    • /
    • 2018
  • Although the voltage-applied discharge method is most widely used in the semiconductor and display industries, periodic management costs are incurred because the method causes defects due to the absorption of ambient fine dust and causes emitter tip contamination due to the discharge. The emitter tip contamination problem is caused by the accumulation of fine particles in ambient air due to the corona discharge of the ionizer. Fuzzy ball generation accelerates the wear of the emitter tip and deteriorates the performance of the ionizer. Although a mechanical cleaning method using a manual brush or an automatic brush is effective for contaminant removal, it requires management of additional mechanical parts by the user. In some cases, contaminants accumulated in the emitter may be transferred to the wafer or product. In order to solve this problem, we developed an ionizer for a clean environment that can remove the pencil-type emitter tip and directly ionize the surrounding gas molecules using the tungsten wire located inside the ion tank. As a result of testing and certification by the Korea Institute of Machinery and Materials, the average concentration was $0.7572particles/ft^3$, the decay time was less than two seconds, and the ion valance was 7.6 V, which is satisfactory.

Development of Good Manufacturing facility for Radiopharmaceuticals (우수방사성의약품 생산시설 개발)

  • Shin, Byung-Chul;Choung, Won-Myung;Park, San-Hyun;Lee, Kyu-Il;Park, Kyung-Bae;Park, Jin-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.2
    • /
    • pp.145-149
    • /
    • 2003
  • Manufacturing facilities of the pharmaceuticals must meet certain level of the cleanness required so that foreign substances such as dust, moisture, heat, microorganism, or virus do not contaminate the product. In case of radiopharmaceuticals for medical treatment and diagnosis, not only should the operators and environment be protected from radiation but also need to be isolated from the foreign contaminant. Therefore, manufacturing facilities for radiopharmaceuticals must satisfy the design standards of both hot cell and clean room which are specified by GMP. However, standards of maintaining negative pressure for preventing spread of radioactive contaminant in isolated facilities conflict with the standards of maintaining positive pressure for keeping cleanness. To solve this problem, air pressure of hot cell was designed lower than in the adjacent area to meet standards of the radiation safety. To keep higher cleanness in certain part of the hot cell for filling, minimal relative positive pressure allows. In order to effectively maintain the cleanness that is required for production of Tc-99m generator, which takes 70% of whole demand of radiopharmaceuticals, the rooms placed in each side of production room are used as a buffer area and three lead hot cells are installed in production room. In this research, we established the appropriate engineered design concept for Tc-99m generator manufacturing facility, which satisfies both GMP cleanness standard for preventing particles, bacteria, other contaminants and the regulations of radiation safety for supervising and controlling the amount of radiation exposure and exhausted radioactivity. And the concept of multi-barrier buffer zones is introduced to apply negative air pressure for hot cell with first priority and to continue relative positive air pressure for clean room.

Study on the Decontamination of Primary Cooling Pump in HANARO (하나로 1차 냉각펌프 제염에 대한 고찰)

  • An Jung-Sug;Lee Kyung-Ho;Kim Kwang-Dug;Park Young-Chul
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.21-29
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Recently, ten years after the initial operation of the HANARO, one of the two primary cooling pumps was decontaminated for overhaul maintenance in 2004. Before decontamination exposure doserate and surface contamination level of primary cooling pump measured at 4 points. After final decontamination exposure doserate and surface contamination level of primary cooling pump remeasured by same method done before. It is easy to decontaminate the out side exposed surfaces of the pump, but it is difficult to approach the inside surface due to double volute installed in the casing. Therefore, a new decontamination facility has been developed to solve this problem. A concentrated de-contaminant (DX-300) is rotated in the closed pump casing by the impeller actuated by a temporary motor. Nuclide particles are removed by the emulsification effect of the de-contaminant and the surface contaminants are chemically removed from the pump by the corrosion and dissolution effect. The inside surfaces of the primary cooling pump have been decontaminated by using the facility. As results, the contamination level of the inside surfaces was maintained below the surface contamination limit.

  • PDF

Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

  • Gehrke, Peter;Tabellion, Astrid;Fischer, Carsten
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.151-159
    • /
    • 2015
  • PURPOSE. To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS. A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non- quantitatively. RESULTS. All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION. The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented.

Microplastic Management for Preventing Risk of Persistent/Bioaccumulative Substance (잔류성.생물축적성 물질 피해저감을 위한 미세플라스틱(Microplastic) 관리방안)

  • Park, Jeong-Gue;Gan, Sun-Yeong
    • Journal of Environmental Policy
    • /
    • v.13 no.2
    • /
    • pp.65-98
    • /
    • 2014
  • Plastics of the marine environment are broken gradually down into smaller particles by chemical weathering, called "microplastic". Microplastics absorb organic pollutants that are persistent bioaccumulative substances. If marine animals ingested microplastic added to contaminant, it will lead to a bioaccumation through the food web. It eventually destroy health of marine environment and is harmful to marine top predators including humans. Also, Microplastics can impact marine animals by leaching the endocrine disruptor in microplastic itself as well as playing an adsorbent role of organic pollutants. Persistent and bioaccumulative substances in Korea have been regulated in terms of chemical risk but existing regulations largely have been limited in land-based source management of microplastic. Thus, the harmful impact will be increased whether the microplastics absorbed contaminants. To prevent risk of persistent bioaccumulative substances, this study suggests the following: (1) the strict management of microplastic by designating the hazardous substances, (2) expand the use of biodegradable plastic, (3) the effort for reuse and recycle, (4) the expand of microplastic clean-up programs.

  • PDF

Effect of Cetyltrimethyl Ammonium Bromide on Foam Stability and SiO2Separation for Decontamination Foam Application (거품제염을 위한 실리카 나노입자와 CTAB (Cetyltrimethyl Ammonium Bromide)의 거품안정성 및 분리특성 평가)

  • Choi, Mansoo;Kim, Seung-Eun;Yoon, In-Ho;Jung, Chong-Hun;Choi, Wang-Kyu;Moon, Jei-Kwon;Kim, Seon-Byeong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.173-182
    • /
    • 2018
  • As part of planning for waste minimization, decontamination foam has been considered as a potential application for the cleaning of radioactive contaminant. In this study, we synthesized silica particles to improve foam stability by varying synthesis parameters. Cetyltrimethylammonium bromide (CTAB) was found to influence the stability of the decontamination foam. The reason was that higher interaction between $SiO_2$ nanoparticles and surfactant at the air-water interface in aqueous solution is beneficial for foam stability. CTAB can also be used as an additive for the aggregation of silica nanoparticles. In the separation of $SiO_2$ nanoparticles, CTAB plays a critical role in the nanoparticles flocculation because of the charge neutralization and hydrophobic effects of its hydrocarbon tails.