• 제목/요약/키워드: Contact resistance

검색결과 1,451건 처리시간 0.021초

$TiSi_2$ SALICIDE CONTACT의 전기적 특성 (Electrical Characteristics of $TiSi_2$ Salicide Contact)

  • 이철진;양지운;이내인;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.178-182
    • /
    • 1991
  • Contact resistance and contact leakage current of the $Al/TiSi_2/Si$ system are investigated for $N^+\;and\;P^+$ junctions. Titanium disilicide is one of the most common silicides because of its thermal stability, ability, to form selective formation and low resistivity. In this paper, the effect of RTA temperature and Junction implant dose are characterized. The $TiSi_2$ contact resistance to $N^+$ silicon is lower than that of Al to $N^+$ silicon, but $TiSi_2$ of contact resistance to $P^+$ silicon is higher than that of Al to $P^+$ silicon. The $TiSi_2$ of contact leakage current to $N^+\;and\;P^+$ silicon is similar to that of Al contact.

  • PDF

Measurement of thermal contact resistance at Cu-Cu interface

  • Kim, Myung Su;Choi, Yeon Suk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.48-51
    • /
    • 2013
  • The thermal contact resistance (TCR) is one of the important components in the cryogenic systems. Especially, cryogenic measurement devices using a cryocooler can be affected by TCR because the systems have to consist of several metal components in contact with each other for heat transferring to the specimen without cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement device using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as roughness of metal surface, contact area and contact pressure. In this study, we designed TCR measurement system at various temperatures using a cryocooler as a heat sink and used steady state method to measure the TCR between metals. The copper is selected as a specimen in the experiment because it is widely used as a heat transfer medium in the cryogenic measurement devices. The TCR between Cu and Cu is measured for various temperatures and contact pressures. The effect of the interfacial materials on the TCR is also investigated.

가스메탈아크용접에서 콘택트팁의 마모에 미치는 용접재료의 영향 (Effect of wear of Contact Tips to Welding Consumable for Gas Metal Arc Welding)

  • 김인규
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.860-864
    • /
    • 2012
  • The contact tip is higher the wear of resistance and the longer life are demanded to GMA welding process. In this study, four different contact tips with three different compositions by two wires were evaluated their wear resistance by measuring in every one hour the area of enlarged hole at the exit side during actual wleding. Experimental results clearly showed that the Cr-containing tips strengthened by precipitation hardening have much better resistance to wear than those made by work hardening. In addition, flux cored wire is excellent abrasion resistance test results showed. Based on these results, the domestic industry, the life of the contact tip to know will be used as basic data.

접촉 열저항을 고려한 합금주조의 응고과정 해석 (An analysis on the solidification process of alloy casting with a contact resistance)

  • 김우승;이관수;임익태;김광선
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.57-67
    • /
    • 1997
  • The solidification process of Al 4.5%Cu alloy is numerically studied in the presence of contact resistance between mold and cast. Natural convection is considered in the liquid and mushy regions. The porosity approach is applied to the mushy zone modeling and linear variation of the solid fraction on the temperature is assumed. Results show that the mushy region is wider in the case with a contact resistance compared to the perfect contact condition. The temperature of the cast with a temporal variation in the contact heat transfer coefficient changes very rapidly in the early stage of the casting process compared to that with constant contact heat transfer coefficient.

플럭스 코어드 와이어에 따른 용접 중 콘택트 팁 내마모성 평가 (Wear Resistance Evaluation of Contact Tip according to Flux Cored Wire)

  • 김동윤;황인성;김동철;강문진
    • Journal of Welding and Joining
    • /
    • 제31권4호
    • /
    • pp.42-46
    • /
    • 2013
  • The contact tip for flux cored arc welding has important functions to transmit the welding current to the wire and to guide the wire to molten pool. A damaged contact tip causes a productivity reduction and a welding quality problem. In this study, the welding experiments for the wear resistance of contact tip regarding flux cored wire types were performed. With two fold type and a seamless type flux cored wires, the wear rates of contact tips were compared. In addition, the wear rate was checked according to the contact tip position.

접촉열전도재를 도포한 접촉열저항 특성연구 (Characterization of Thermal Contact Resistance Doped with Thermal Interface Material)

  • ;;;문병준;이선규
    • 한국정밀공학회지
    • /
    • 제30권9호
    • /
    • pp.943-950
    • /
    • 2013
  • This paper describes the thermal contact resistance and its effect on the performance of thermal interface material. An ASTM D 5470 based apparatus is used to measure the thermal interface resistance. Bulk thermal conductivity of different interface material is measured and compared with manufacturers' data. Also, the effect of grease void in the contact surface is investigated using the same apparatus. The flat type thermal interface tester is proposed and compared with conventional one to consider the effect of lateral heat flow. The results show that bulk thermal conductivity alone is not the basis to select the interface material because high bulk thermal conductivity interface material can have high thermal contact resistance, and that the center voiding affects the thermal interface resistance seriously. On the aspect of heat flow direction, thermal impedance of the lateral heat flow shows higher than that of the longitudinal heat flow by sixteen percent.

Effects of Thermal Contact Resistance on Film Growth Rate in a Horizontal MOCVD Reactor

  • Im Ik-Tae;Choi Nag Jung;Sugiyama Masakazu;Nakano Yoshiyaki;Shimogaki Yukihiro;Kim Byoung Ho;Kim Kwang-Sun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권6호
    • /
    • pp.1338-1346
    • /
    • 2005
  • Effects of thermal contact resistance between heater and susceptor, susceptor and graphite board in a MOCVD reactor on temperature distribution and film growth rate were analyzed. One-dimensional thermal resistance model considering thermal contact resistance and heat transfer area was made up at first to find the temperature drop at the surface of graphite board. This one-dimensional model predicted the temperature drop of 18K at the board surface. Temperature distribution of a reactor wall from the three-dimensional computational fluid dynamics analysis including the gap at the wafer position showed the temperature drop of 20K. Film growth rates of InP and GaAs were predicted using computational fluid dynamics technique with chemical reaction model. Temperature distribution from the three-dimensional heat transfer calculation was used as a thermal boundary condition to the film growth rate simulations. Temperature drop due to the thermal contact resistance affected to the GaAs film growth a little but not to the InP film growth.

화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구 (A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession)

  • 정병선;김응식;박종열
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

Contact resistance increment of no-insulation REBCO magnet during a quench

  • Im, Chaemin;Cho, Mincheol;Bang, Jeseok;Kim, Jaemin;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권1호
    • /
    • pp.31-35
    • /
    • 2019
  • The lumped-parameter circuit model for a no- insulation (NI) high temperature superconductor (HTS) magnet has been well understood after many experimental and analytic studies over a decade. It successfully explains the non-linear charging behaviors of NI magnets. Yet, recently, multiple groups reported that the post-quench electromechanical behaviors of an NI HTS magnet may not be well explained by the lumped circuit model. The characteristic resistance of an NI magnet is one of the key parameters to characterize the so-called "NI behaviors" of an NI magnet and recently a few groups reported a potential that the characteristic resistance of an NI magnet may substantially vary during a quench. This paper deals with this issue, the increment of contact resistance of the no-insulation (NI) REBCO magnet during a quench and its impact on the post-quench behaviors. A 7 T 78 mm NI REBCO magnet that was previously built by the MIT Francis Bitter Magnet Laboratory was chosen for our simulation to investigate the increment of contact resistance to better duplicate the post-quench coil voltages in the simulation. The simulation results showed that using the contact resistance value measured in the liquid nitrogen test, the magnitude of the current through the coil must be much greater than the critical current. This indicates that the value of the contact resistance should increase sharply after the quench occurs, depending on the lumped circuit model.

MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템 (The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester)

  • 부라윤;최정훈;이명의
    • 한국항행학회논문지
    • /
    • 제27권2호
    • /
    • pp.203-208
    • /
    • 2023
  • 본 연구에서는 정전류 회로와 전압 강하법을 이용한 접촉 저항 측정 회로의 정밀도를 개선하는 방법을 제안하고, MQTT 브로커 서버를 통해 접촉 저항 측정 시스템의 측정값을 모니터링할 수 있는 대시보드를 구현한다. 접촉 저항 측정 시스템은 저항값을 측정하고 무선통신을 이용해 MQTT 브로커 서버로 측정값을 전달하고, 대시보드는 Node-RED와 Node-RED-Dashboard을 이용하여 최대 4개의 접촉저항 측정 시스템의 저항값을 받아 이를 사용자 화면에 출력하여 보여준다. 사용자는 하나의 대시보드를 이용해 복수의 측정 데이터를 관리할 수 있고, MQTT 브로커 서버를 통해 다른 장치와 쉽게 인터페이스 가능하게 한다. 실제 데이터 측정을 통해 정밀도 상대표준편차가 평균적으로 40.37%, 그리고 최대 64.73% 각각 감소하여 정밀도의 개선 효과가 있다.