• Title/Summary/Keyword: Contact configuration

Search Result 218, Processing Time 0.025 seconds

Transmit Antenna Selection for Dual Polarized Channel Using Singular Value Decision

  • Lee Sang-yub;Mun Cheol;Yook Jong-gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9A
    • /
    • pp.788-794
    • /
    • 2005
  • In this paper, we focus on the potential of dual polarized antennas in mobile system. thus, this paper designs exact dual polarized channel with Spatial Channel Model (SCM) and investigates the performance for certain environment. Using proposed the channel model; we know estimates of the channel capacity as a function of cross polarization discrimination (XPD) and spatial fading correlation. It is important that the MIMO channel matrix consists of Kronecker product dividable spatial and polarized channel. Through the channel characteristics, we propose an algorithm for the adaptation of transmit antenna configuration to time varying propagation environments. The optimal active transmit antenna subset is determined with equal power allocated to the active transmit antennas, assuming no feedback information on types of the selected antennas. We first consider a heuristic decision strategy in which the optimal active transmit antenna subset and its system capacity are determined such that the transmission data rate is maximized among all possible types. This paper then proposes singular values decision procedure consisting of Kronecker product with spatial and polarize channel. This method of singular value decision, which the first channel environments is determined using singular values of spatial channel part which is made of environment parameters and distance between antennas. level of correlation. Then we will select antenna which have various polarization type. After spatial channel structure is decided, we contact polarization types which have considerable cases It is note that the proposed algorithms and analysis of dual polarized channel using SCM (Spatial Channel Model) optimize channel capacity and reduce the number of transmit antenna selection compare to heuristic method which has considerable 100 cases.

Pool Boiling Enhancement of R-123 Using Perforated Plates (다공판을 사용한 R-123 풀비등 열전달 촉진)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.275-281
    • /
    • 2016
  • In this study, we investigate the pool boiling enhancement caused by perforated plates on top of a smooth surface. We conduct tests using R-123 at atmospheric pressure. It was shown that perforated plates significantly enhanced the pool boiling of the smooth surface. The reason may be attributed to the increased bubble contact area between the plates. The results showed that the enhancement ratio was dependent on the heat flux. At high heat flux, the enhancement ratio increased as the porosity increased. However, at low heat flux, the enhancement ratio decreased as the porosity increased. For the present investigation, the optimum configuration had a pore diameter of 2.0 mm, pore pitch of $2.5mm{\times}5.0mm$ or $5.0mm{\times}5.0mm$, and a gap width of 0.5 mm, which yielded heat-transfer coefficients that are close to those of GEWA-T. The optimum porosity for R-123 was significantly larger than that of water or ethanol. The reason for this may be the large liquid-to-vapor density ratio along with the small latent heat of vaporization of R-123. The perforated plates yielded smaller boiling hysteresis compared with that of the smooth surface.

Role of Arbitrary Intensity Profile Laser Beam in Trapping of RBC for Phase-imaging

  • Kumar, Ranjeet;Srivastava, Vishal;Mehta, Dalip Singh;Shakher, Chandra
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.78-87
    • /
    • 2016
  • Red blood cells (RBCs) are customarily adhered to a bio-functionalised substrate to make them stationary in interferometric phase-imaging modalities. This can make them susceptible to receive alterations in innate morphology due to their own weight. Optical tweezers (OTs) often driven by Gaussian profile of a laser beam is an alternative modality to overcome contact-induced perturbation but at the same time a steeply focused laser beam might cause photo-damage. In order to address both the photo-damage and substrate adherence induced perturbations, we were motivated to stabilize the RBC in OTs by utilizing a laser beam of ‘arbitrary intensity profile’ generated by a source having cavity imperfections per se. Thus the immobilized RBC was investigated for phase-imaging with sinusoidal interferograms generated by a compact and robust Michelson interferometer which was designed from a cubic beam splitter having one surface coated with reflective material and another adjacent coplanar surface aligned against a mirror. Reflected interferograms from bilayers membrane of a trapped RBC were recorded and analyzed. Our phase-imaging set-up is limited to work in reflection configuration only because of the availability of an upright microscope. Due to RBC’s membrane being poorly reflective for visible wavelengths, quantitative information in the signal is weak and therefore, the quality of experimental results is limited in comparison to results obtained in transmission mode by various holographic techniques reported elsewhere.

Effect of Shape and Flow Rate on T10 in Clearwell (정수지의 형상과 유입 유량이 T10에 미치는 영향 연구)

  • Shin, Eun-Her;Kim, Sung-Hoon;Park, Hee-Kyung;Ahn, Jae-Chan;Choi, Jae-Ho;Choi, Young-June
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.819-826
    • /
    • 2005
  • To guarantee the disinfection ability in clearwell, a value of CT is considered where C[mg/l] is disinfectant residual at the exit of clearwell and T[min] means $T_{10}$, the contact time when 10% of tracer is out of clearwell after introducing the tracer at the inlet. To meet a CT value required, increasing the C value is not recommended because high C value can increase potential of producing disinfection by product like THMs. Increasing the hydraulic efficiency surrogated by $T_{10}$ is thus an option widely recommended. Right now, it is widely adopted estimating $T_{10}$ considering LW ratio only due to the suggestions of previous researches. The authors think however there are other factors to consider including shape, flow rate, configuration of inlet and outlet, and the existence of intra basin. This study is initiated to closely look at the effects of two factor on hydraulic efficiency. The factors are shape and inlet flow velocity, i.e., inflow. For that, computational fluid dynamics (CFD) model is developed and pilot test is also carried out. The results show that at a L/W ratio, disinfection ability is overestimated with larger length in shape and higher inlet flow velocity. This suggests that in determining $T_{10}$, the shapes of clearwell and inlet flow velocity should also be considered as well as L/W ratio.

Fabrication Of Ultraviolet LED Light Source Module Of Current Limiting Diode Circuit By Using Flip Chip Micro Soldering (마이크로솔더링을 이용한 정전류다이오드 회로 자외선 LED 광원모듈 제작)

  • Park, Jong-Min;Yu, Soon Jae;Kawan, Anil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.237-240
    • /
    • 2016
  • The improvement of irradiation intensity and irradiation uniformity is essential for large area and high power UVA light source application. In this study, large number of chips bonded by micro soldering technique were driven by low current, and current limiting diodes were configured to supply constant current to parallel circuits consisting of large number of series strings. The dimension of light source module circuit board was $350{\times}90mm^2$ and 16,650 numbers of 385 nm flip chip LEDs were used with a configuration of 90 parallel and 185 series strings. The space between LEDs in parallel and series strings were maintained at 1.9 mm and 1.0 mm distance, respectively. The size of the flip chip was $750{\times}750{\mu}m^2$ were used with contact pads of $260{\times}669{\mu}m^2$ size, and SAC (96.5 Sn/3.0 Ag/0.5 Cu) solder was used for flip chip bonding. The fabricated light source module with 7.5 m A supply current showed temperature rise of $66^{\circ}C$, whereas irradiation was measured to be $300mW/cm^2$. Inaddition, 0.23% variation of the constant current in each series string was demonstrated.

A study on a dielectric heating system for amplifying the resonant gain using the capacitance of electrodes (전극의 용량성분을 이용한 공진이득 증폭형 유전가열장치에 관한 연구)

  • Kim, Shin-Hyo;Lee, Chang-Woo;Bae, Han-Nah;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.940-946
    • /
    • 2015
  • In this paper, we study a method that amplifies the output gain of a high voltage pulse using 300 kHz or higher frequency. We conducted a study on a method for amplifying the output gain using the resonance between the capacitance components of the load and the parasitic components of the circuit, instead of the conservative method for amplifying the pulse-amplitude by raising the voltage of the power stage. In particular, the method simplifies the circuit configuration throughout the appliance of flyback-type topology instead of the bridge-type. There are advantages that prevent damage from overload and the heat in the output circuit through the hard switching by amplifying the gain of the output voltage applying to the load as given by the capacitance component of the output electrode to the output pulse waveform. This study proposed a method to enhance the spatial and electrical efficiency of the contact-type heating device through the dielectric heating method applied to the field of medical and industrial heating.

Numerical Analysis of the Initiation and Development of Corrugation on a Gravel Road (수치해석적 기법을 활용한 골재 도로의 콜루게이션 발생 및 진전 분석)

  • Yun, Taeyoung;Chung, Taeil;Shin, Hyu-Soung
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.9-18
    • /
    • 2018
  • PURPOSES : In this research, the initiation and development of corrugation on a gravel road with certain wheel and boundary conditions were evaluated using a coupled discrete-element method (DEM) with multibody dynamics (MBD). METHODS : In this study, 665,534 particles with a 4-mm diameter were generated and compacted to build a circular roadbed track, with a depth and width of 42 mm and 50 mm, respectively. A single wheel with a 100-mm diameter, 40-mm width, and 0.157-kg mass was considered for the track. The single wheel was set to run slowly on the track with a speed of 2.5 rad/s so that the corrugation was gradually initiated and developed without losing contact between the wheel and the roadbed. Then, the shape of the track surface was monitored, and the movement of the particles in the roadbed was tracked at certain wheel-pass numbers to evaluate the overall corrugation initiation and development mechanism. RESULTS : Two types of corrugation, long wave-length and short wave-length, were observed in the circular track. It seems that the long wave-length corrugation was developed by the longitudinal movement of surface particles in the entire track, while the short wave-length corrugation was developed by shear deformation in a local section. Properties such as particle coefficients, track bulk density, and wheel mass, have significant effects on the initiation and development of long-wave corrugation. CONCLUSIONS : It was concluded that the coupled numerical method applied in this research could be effectively used to simulate the corrugation of a gravel road and to understand the mechanism that initiates and develops corrugation. To derive a comprehensive conclusion for the corrugation development under various conditions, the driver's acceleration and deceleration with various particle gradations and wheel-configuration models should be considered in the simulation.

Low Temperature Hermetic Packaging using Localized Beating (부분 가열을 이용한 저온 Hermetic 패키징)

  • 심영대;김영일;신규호;좌성훈;문창렬;김용준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1033-1036
    • /
    • 2002
  • Wafer bonding methods such as fusion and anodic bonding suffer from high temperature treatment, long processing time, and possible damage to the micro-scale sensor or actuators. In the localized bonding process, beating was conducted locally while the whole wafer is maintained at a relatively low temperature. But previous research of localized heating has some problems, such as non-uniform soldering due to non-uniform heating and micro crack formation on the glass capsule by thermal stress effect. To address this non-uniformity problem, a new heater configuration is being proposed. By keeping several points on the heater strip at calculated and constant potential, more uniform heating, hence more reliable wafer bonding could be achieved. The proposed scheme has been successfully demonstrated, and the result shows that it will be very useful in hermetic packaging. Less than 0.2 ㎫ contact Pressure were used for bonding with 150 ㎃ current input for 50${\mu}{\textrm}{m}$ width, 2${\mu}{\textrm}{m}$ height and 8mm $\times$ 8mm, 5mm$\times$5mm, 3mm $\times$ 3mm sized phosphorus-doped poly-silicon micro heater. The temperature can be raised at the bonding region to 80$0^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional micro heaters. For gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for gross leak check. The pass ratio of bonded dies was 70%, for conventional localized heating, and 85% for newly developed FP scheme. The bonding strength was more than 30㎫ for FP scheme packaging, which shows that FP scheme can be a good candidate for micro scale hermetic packaging.

  • PDF

Designing a kmultiview 3D display system based on a spatiotemporal multiplexing (시공 분할방식을 이용한 다시점 삼차원 디스플레이 시스템의 설계)

  • 손정영;김재순;전호인
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.368-372
    • /
    • 1998
  • A 16-views 3 dimensional imaging system is designed by spatially combinding two 8-views time multiplexed image channels. Each 8-views channel composed of 3 primary color CRTs and a dichroic beam splitter which combining the three CRTs as one channel. Each CRT displays 8-view images time sequentially. These images are projected to a holographic screen of a size 1$\times$0.8 $m^2$ through a projection optics. Characteristics of the three different configurations of projection optics are examined with the optics designing program "DEMOS" to select an optimized projection optics for the system. The configulation of the optimized projection optics is found like following; images from each channel combined by two-fold mirror are projected by a projection objective through a 16-strips LCD shutter. In this configuration, the shutter should be located at the entrance pupil of the objective, and the folded edge of the two-fold mirror should contact symmetrically to the center line of the shutter.e shutter.

  • PDF

Development of portable single-beam acoustic tweezers for biomedical applications (생체응용을 위한 휴대용 단일빔 음향집게시스템 개발)

  • Lee, Junsu;Park, Yeon-Seong;Kim, Mi-Ji;Yoon, Changhan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.435-440
    • /
    • 2020
  • Single-beam acoustic tweezers that are capable of manipulating micron-size particles in a non-contact manner have been used in many biological and biomedical applications. Current single-beam acoustic tweezer systems developed for in vitro experiments consist of a function generator and a power amplifier, thus the system is bulky and expensive. This configuration would not be suitable for in vivo and clinical applications. Thus, in this paper, we present a portable single-beam acoustic tweezer system and its performances of trapping and manipulating micron-size objects. The developed system consists of an Field Programmable Gate Array (FPGA) chip and two pulsers, and parameters such as center frequency and pulse duration were controlled by a Personal Computer (PC) via a USB (Universal Serial Bus) interface in real-time. It was shown that the system was capable of generating the transmitting pulse up to 20 MHz, and producing sufficient intensity to trap microparticles and cells. The performance of the system was evaluated by trapping and manipulating 40 ㎛ and 90 ㎛ in diameter polystyrene particles.