• 제목/요약/키워드: Contact Ratio

검색결과 1,204건 처리시간 0.025초

인벌류트 베벨기어 설계 기술에 관한 연구 (A Study on Technology for Involute Bevel Gear Design)

  • 조성철
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.44-50
    • /
    • 2003
  • Design method for involute bevel gears is developed. The developed gear design system can design the optimized gear that minimize the number of pinion teeth with face tooth. Method of optimization is MS(matrix search) which is developed from this study. Design variables are pressure angle 20., transmitted power, gear volume, gear ratio, allowable contact stress and allowable bending stress. etc. Gears design method developed this study can be applied to the plane, helicopter, printer, machine tools.

스퍼기어의 접촉응력 해석 (Contact Stress Analysis of a Pair of Mating Spur Gears)

  • 이진환;이동형;이권희
    • 한국기계가공학회지
    • /
    • 제9권4호
    • /
    • pp.59-65
    • /
    • 2010
  • This paper presents the study on the contact stress analysis of a pair of mating spur gears during rotation. Contact stress analysis is performed between two spur gear teeth at different contact positions during rotation. An example is presented to investigate the variation of contact stress on a pair of mating gears with contact positions. The variation of contact stress during rotation is compared with the contact stress at lowest point of single tooth contact(LPSTC) and AGMA Equation for contact stress. The results show that contact stress varies along the contact position and gets maximum values in the beginning and end of the contact. In this study, the gear design considering the contact stress on a pair of mating gears is more severe than that of AGMA standard.

근접촉쌍성(NCBs)의 물리적 특성에 대한 통계적 분석 (STATISTICAL SURVEY FOR THE PHYSICAL CHARACTERISTIC OF NEAR CONTACT BINARY(NCBs))

  • 오규동
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권3호
    • /
    • pp.233-242
    • /
    • 2005
  • 66개의 근접촉쌍성(이하 NCBb)의 절대물리량과 궤도요소를 여러 목록으로부터 수집 분석하여 여러 물리량 사이의 상관관계와 NCBs의 물리적 특성을 조사하였다 NCBs의 질량비-광도비 관계는 $L_2/L_1{\lapprox}(M_2/M_1)^{1.45}$로 나타났으며 CE형에 더 근접한 특성을 보였다. NCBs의 여러 물리량 사이의 상관관계에 따르면 F형이 A형에 비하여 주성과 반성의 질량, 반경, 광도 및 온도의 차이가 작게 나타났다. NCBs의 H-R도에 따르면 A형이 F형에 비하여 다소 더 진화된 종년주계열(TAMS)에 가까이 나타나고 있다.

질량비가 작은 접촉쌍성 GR Vir과 HV Aqr (SMALL MASS RATIO CONTACT BINARY GR Vir AND HV Aqr)

  • 오규동;김천휘;강영운;김호일;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • 제21권2호
    • /
    • pp.83-92
    • /
    • 2004
  • 질량비가 작은 접촉쌍성 GR Vir와 HV Aqr의 이미 발표된 분광 및 측광관측치를 WD프로그램에 적용하여 이 별들의 새로운 절대 물리량을 얻었다. GR Vir과 HV Aqr를 포함한 17개의 질량비가 작은 접촉쌍성들의 친화 상태를 조사하였다. 그 결과 질량비가 작은 접촉쌍성의 주성은 대부분 종년주계열상에 놓이며 반성은 영년주계열 아래 놓이고 있음을 확인하였다.

비접촉식 설면 습윤도 측정 기구의 개발 (Development of the non contact tongue moisture measuring device)

  • 김대복;박유경;김기왕
    • 대한한의진단학회지
    • /
    • 제14권2호
    • /
    • pp.67-74
    • /
    • 2010
  • Objectives: Tongue moisture is one of major features in tongue diagnosis of Oriental Medicine. But with regard to the methods to qualify the tongue moisture level, there have been no adequate modalities to satisfy clinicians' needs. So we developed an novel device and method to quantify the tongue moisture level without contact. Methods and Materials: Ratio of saturated area to total tongue area in the image captured with a spot light at various angles was calculated. We regarded that ratio represented the moisture of tongue surface. To evaluate the performance of suggested method, we observed the correlation between conventional contact method and our method with 19 healthy subjects. Results: With comparison to conventional contact method (Schirmer test), the suggested method showed good correlation (R = 0.8602, R2 = 0.7399). Conclusion: This Method could be a convenient and robust method to evaluate tongue moisture.

에너지 구조재 적용을 위한 알루미늄/섬유강화 복합재의 표면처리 (Surface Treatment of Aluminum/ Fiber- Reinforced Composites As Energy-Saving Light Structures)

  • 이경엽;강용태;양준호
    • 한국표면공학회지
    • /
    • 제34권1호
    • /
    • pp.56-61
    • /
    • 2001
  • In this work, the surface treatment of aluminum/composites (graphite-epoxy composites) was investigated. The surface of composites was treated by $Ar^{+}$ ion beam under oxygen environment. The surface of aluminum was treated by DC plasma. The optimal condition of surface treatment for the composites was determined by measuring the contact angle as a function of ion dose. The optimal treatment condition of the aluminum was determined by measuring the contact angle and T-peel strength as a function of mixture ratio of acetylene gas to nitrogen gas. The mixture ratios used were 1:9, 3:7, 5:5, 7:3, and 9:1. The results showed that the contact angle of composites decreased from$ 81^{\circ}$ to $8^{\circ}$ as the ion dose increased from zero to $1$\times$10^{17}$ions/$\textrm{cm}^2$. The optimal condition of ion dose was $1$\times$10^{16}$ions/$\textrm{cm}^2$. The results also showed that the contact angle of aluminum was a minimum for the mixture ratio of 5:5. Similarly, the T-peel strength was a maximum for the mixture ratio of 5:5, which indicates that the optimal condition of mixture ratio of acetylene gas to nitrogen gas is 5:5.

  • PDF

질량비가 작은 접촉쌍성 V410 Aur과 V776 Cas-II (LOW MASS RATIO CONTACT BINARY V410 Aur AND V776 Cas-II)

  • 오규동;김천휘;김호일
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권3호
    • /
    • pp.223-232
    • /
    • 2005
  • 질량비가 작은 접촉쌍성 V410 Aur과V776 Cas를 소백산천문대의 61cm망원경에 2K CCD 카메라를 부착하여 측광 관측을 하였으며, 그 결과 이 별들의 새로운 3색(BVR)의 완전한 광도곡선을 얻었다. 새로운 광도곡선과 이미 발표된 분광관측으로부터 WD모델을 이용하여 이 두 별의 궤도요소와 절대 물리량을 얻었다. V410 Aur과 V776 Cas를 포함한 절대물리량이 잘 알려진 19개의 질량비가 작은 접촉쌍성들의 진화 상태를 조사하였다. 그 결과 질량비가 작은 접촉쌍성의 주성은 대부분 TAMS상에 놓이며 반성은 ZAMS 아래 놓이고 있음을 재확인하였다.

Allergy성(性) 접촉피부염(接觸皮膚炎)에 대(對)한 고삼(苦蔘), 황연(黃連)의 Iontophoresis 치료(治療) 효과(效果) (The Effects of Sophorae Radix and Coptidis Rhizoma - Iontophoresis in Allergic Contact Dermatitis -)

  • 김찬중;구영희;남혜정;김윤범
    • 한방안이비인후피부과학회지
    • /
    • 제18권1호
    • /
    • pp.199-220
    • /
    • 2005
  • Objective : This study was performed to investigate the effects of Sophorae Radix and Coptidis Rhizoma-iontophoresis in allergic contact dermatitis. Methods : Contact hypersensitivity assay, video microscope, melanin-erythema levels, pH levels, hydration levels, WBC count, RBC count, neutrophil ratio, lymphocyte ratio and total IgE levels were measured. Results : At contact hypersensitivity assay, the right ear swellings in Sophorae Radix and Coptidis Rhizoma-iontophoresis group were decreased compared with control group, but have no statistical significance. At observation of skin morphologic change, many papules were seen in control group and keratins were seen in Sophorae Radix-iontophoresis group. At melanin levels, Sophorae Radix and Coptidis Rhizoma-iontophoresis groups showed no significant difference compared with control group. At pH levels, Sophorae Radix-iontophoresis group showed significant decreased with control group. At hydration levels, Sophorae Radix and Coptidis Rhizoma-iontophoreses groups showed to significant difference compared with control group. WBC count, RBC count and neutrophil ratio were significantly increased in Sophorae Radix and Coptidis Rhizoma-iontophoresis group compared with control group. Lymphocyte ratio and total IgE levels were significantly decreased in Sophorae Radix and Coptidis Rhizoma-iontophoresis groups compared with control group. At morphology of skin, inflammation was decreased and the thickness of epidermis was well preserved in Sophorae Radix and Coptidis Rhizoma-iontophoresis group. Conclusion : Sophorae Radix and Coptidis Rhizoma-iontophoresis had some anti-allergy, anti-inflammatory effects on allergic contact dermatitis, but had no effects on melanin-erythema levels, pH levels and hydration levels of skin.

  • PDF

높은 A/R의 콘택 산화막 에칭에서 바닥모양 변형 개선에 관한 연구 (A Study on The Improvement of Profile Tilting or Bottom Distortion in HARC)

  • 황원태;김길호
    • 한국전기전자재료학회논문지
    • /
    • 제18권5호
    • /
    • pp.389-395
    • /
    • 2005
  • The etching technology of the high aspect ratio contact(HARC) is necessary at the critical contact processes of semiconductor devices. Etching the $SiO_{2}$ contact hole with the sub-micron design rule in manufacturing VLSI devices, the unexpected phenomenon of 'profile tilting' or 'bottom distortion' is often observed. This makes a short circuit between neighboring contact holes, which causes to drop seriously the device yield. As the aspect ratio of contact holes increases, the high C/F ratio gases, $C_{4}F_{6}$, $C_{4}F_{8}$ and $C_{5}F_{8}$, become widely used in order to minimize the mask layer loss during the etching process. These gases provide abundant fluorocarbon polymer as well as high selectivity to the mask layer, and the polymer with high sticking yield accumulates at the top-wall of the contact hole. During the etch process, many electrons are accumulated around the asymmetric hole mouth to distort the electric field, and this distorts the ion trajectory arriving at the hole bottom. These ions with the distorted trajectory induce the deformation of the hole bottom, which is called 'profile tilting' or 'bottom distortion'. To prevent this phenomenon, three methods are suggested here. 1) Using lower C/F ratio gases, $CF_{4}$ or $C_{3}F_{8}$, the amount of the Polymer at the hole mouth is reduced to minimize the asymmetry of the hole top. 2) The number of the neighboring holes with equal distance is maximized to get the more symmetry of the oxygen distribution around the hole. 3) The dual frequency plasma source is used to release the excessive charge build-up at the hole mouth. From the suggested methods, we have obtained the nearly circular hole bottom, which Implies that the ion trajectory Incident on the hole bottom is symmetry.

계수기용 비인벌류트 치형의 내치차 설계와 물림해석 (Design and Meshing Analysis of a Non-involute Internal Gear for Counters)

  • 이성철
    • Tribology and Lubricants
    • /
    • 제30권4호
    • /
    • pp.212-217
    • /
    • 2014
  • A counter gear transmits the rotation angle, so the angular velocity ratio of the gear does not necessarily need to be constant in the meshing process. As a pinion has a small number of teeth when combined with an internal gear for counters, tooth interference can occur with the use of an involute curve. This paper introduces circular arcs that represent a tooth profile and fillet for the profile design of a pinion through the combination of arcs with lines. The straight line of a rack tooth represents the profile of a mating internal gear. Thus, the circular arc and line maintain contact during the rotation of the counter gear. This paper presents an analysis of the meshing of the circular arc tooth and rack tooth along with the properties of the counter gear, such as the change in rotational velocity and amount of backlash. The contact ratio of the counter gear is 1 because the tooth contact occurs between circular arcs and line. The initial position of tooth contact, which denotes the simultaneous contact of two teeth, is found. As the rotation of the pinion, only one tooth keeps the contact situation. This meshing property is analyzed by the geometrical constraints of the tooth profile in contact and the results are presented as graphical diagrams in which tooth-arc movements are superimposed.