• Title/Summary/Keyword: Contact Ratio

Search Result 1,190, Processing Time 0.028 seconds

A Study on Technology for Involute Bevel Gear Design (인벌류트 베벨기어 설계 기술에 관한 연구)

  • Cho, Seong-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.44-50
    • /
    • 2003
  • Design method for involute bevel gears is developed. The developed gear design system can design the optimized gear that minimize the number of pinion teeth with face tooth. Method of optimization is MS(matrix search) which is developed from this study. Design variables are pressure angle 20., transmitted power, gear volume, gear ratio, allowable contact stress and allowable bending stress. etc. Gears design method developed this study can be applied to the plane, helicopter, printer, machine tools.

Contact Stress Analysis of a Pair of Mating Spur Gears (스퍼기어의 접촉응력 해석)

  • Lee, Jin-Hwan;Lee, Dong-Hyong;Lee, Kwon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.59-65
    • /
    • 2010
  • This paper presents the study on the contact stress analysis of a pair of mating spur gears during rotation. Contact stress analysis is performed between two spur gear teeth at different contact positions during rotation. An example is presented to investigate the variation of contact stress on a pair of mating gears with contact positions. The variation of contact stress during rotation is compared with the contact stress at lowest point of single tooth contact(LPSTC) and AGMA Equation for contact stress. The results show that contact stress varies along the contact position and gets maximum values in the beginning and end of the contact. In this study, the gear design considering the contact stress on a pair of mating gears is more severe than that of AGMA standard.

STATISTICAL SURVEY FOR THE PHYSICAL CHARACTERISTIC OF NEAR CONTACT BINARY(NCBs) (근접촉쌍성(NCBs)의 물리적 특성에 대한 통계적 분석)

  • Oh, Kyu-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.233-242
    • /
    • 2005
  • The absolute dimensions and orbital elements of 66 near contact binaries, collected from literatures, have been analyzed to investigate the physical characteristics of the near contact binaries as well as co-relations among physical parameters. The relationship between the mass ratio and luminosity ratio of the near contact binary systems have been obtained as a $L_2/L_1{\approx}(M_2/M_1)^{1.45}$, which is similar to that of the early type contact binary system. The physical parameters of the new contact binaries show that the difference in mass, radius, luminosity and temperature between the primary and the secondary components for the F type NCBs are smaller than those for the A type NCBs. In H-R diagram, the components of the A types are located closer to the terminal age main sequence than those of the F types.

SMALL MASS RATIO CONTACT BINARY GR Vir AND HV Aqr (질량비가 작은 접촉쌍성 GR Vir과 HV Aqr)

  • 오규동;김천휘;강영운;김호일;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.83-92
    • /
    • 2004
  • The absolute dimensions of low mass contact binary, GR Vir and HV Aqr were obtained using WD program from the published spectroscopic and photometric observational data. The evolutionary status of this type of system including GR Vir and HV Aqr has been considered. The primary stars of low mass contact binary system were located on the Terminal Age Main-sequence and secondary stars were located under the Zero Age Main-sequence in H-R diagram.

Development of the non contact tongue moisture measuring device (비접촉식 설면 습윤도 측정 기구의 개발)

  • Kim, Dae-Bok;Park, Yu-Gyung;Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • Objectives: Tongue moisture is one of major features in tongue diagnosis of Oriental Medicine. But with regard to the methods to qualify the tongue moisture level, there have been no adequate modalities to satisfy clinicians' needs. So we developed an novel device and method to quantify the tongue moisture level without contact. Methods and Materials: Ratio of saturated area to total tongue area in the image captured with a spot light at various angles was calculated. We regarded that ratio represented the moisture of tongue surface. To evaluate the performance of suggested method, we observed the correlation between conventional contact method and our method with 19 healthy subjects. Results: With comparison to conventional contact method (Schirmer test), the suggested method showed good correlation (R = 0.8602, R2 = 0.7399). Conclusion: This Method could be a convenient and robust method to evaluate tongue moisture.

Surface Treatment of Aluminum/ Fiber- Reinforced Composites As Energy-Saving Light Structures (에너지 구조재 적용을 위한 알루미늄/섬유강화 복합재의 표면처리)

  • 이경엽;강용태;양준호
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.1
    • /
    • pp.56-61
    • /
    • 2001
  • In this work, the surface treatment of aluminum/composites (graphite-epoxy composites) was investigated. The surface of composites was treated by $Ar^{+}$ ion beam under oxygen environment. The surface of aluminum was treated by DC plasma. The optimal condition of surface treatment for the composites was determined by measuring the contact angle as a function of ion dose. The optimal treatment condition of the aluminum was determined by measuring the contact angle and T-peel strength as a function of mixture ratio of acetylene gas to nitrogen gas. The mixture ratios used were 1:9, 3:7, 5:5, 7:3, and 9:1. The results showed that the contact angle of composites decreased from$ 81^{\circ}$ to $8^{\circ}$ as the ion dose increased from zero to $1$\times$10^{17}$ions/$\textrm{cm}^2$. The optimal condition of ion dose was $1$\times$10^{16}$ions/$\textrm{cm}^2$. The results also showed that the contact angle of aluminum was a minimum for the mixture ratio of 5:5. Similarly, the T-peel strength was a maximum for the mixture ratio of 5:5, which indicates that the optimal condition of mixture ratio of acetylene gas to nitrogen gas is 5:5.

  • PDF

LOW MASS RATIO CONTACT BINARY V410 Aur AND V776 Cas-II (질량비가 작은 접촉쌍성 V410 Aur과 V776 Cas-II)

  • Oh, Kyu-Dong;Kim, Chun-Hwey;Kim, Ho-il
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.223-232
    • /
    • 2005
  • New BVR CCD light curves of the low mass ratio contact binaries, V410 Aur and V776 Cas, were observed with the 61 cm reflector and a 2K CCD camera at the Sobaeksan Astronomical Observatory. The absolute dimensions of the low mass ratio contact binaries, V410 Aur and V776 Cas, were obtained using WD program from the published spectroscopic and newly observed photometric data. The evolutionary status of this type of binary system including V410 Aur and V776 Cas has been considered. We reconfirmed that the primary stars of the low mass contact binary system were located on the TAMS and secondary stars were located under the ZAMS in H-R diagram.

The Effects of Sophorae Radix and Coptidis Rhizoma - Iontophoresis in Allergic Contact Dermatitis - (Allergy성(性) 접촉피부염(接觸皮膚炎)에 대(對)한 고삼(苦蔘), 황연(黃連)의 Iontophoresis 치료(治療) 효과(效果))

  • Kim, Chan-Jung;Ku, Young-Hui;Nam, Hae-Jeong;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.18 no.1
    • /
    • pp.199-220
    • /
    • 2005
  • Objective : This study was performed to investigate the effects of Sophorae Radix and Coptidis Rhizoma-iontophoresis in allergic contact dermatitis. Methods : Contact hypersensitivity assay, video microscope, melanin-erythema levels, pH levels, hydration levels, WBC count, RBC count, neutrophil ratio, lymphocyte ratio and total IgE levels were measured. Results : At contact hypersensitivity assay, the right ear swellings in Sophorae Radix and Coptidis Rhizoma-iontophoresis group were decreased compared with control group, but have no statistical significance. At observation of skin morphologic change, many papules were seen in control group and keratins were seen in Sophorae Radix-iontophoresis group. At melanin levels, Sophorae Radix and Coptidis Rhizoma-iontophoresis groups showed no significant difference compared with control group. At pH levels, Sophorae Radix-iontophoresis group showed significant decreased with control group. At hydration levels, Sophorae Radix and Coptidis Rhizoma-iontophoreses groups showed to significant difference compared with control group. WBC count, RBC count and neutrophil ratio were significantly increased in Sophorae Radix and Coptidis Rhizoma-iontophoresis group compared with control group. Lymphocyte ratio and total IgE levels were significantly decreased in Sophorae Radix and Coptidis Rhizoma-iontophoresis groups compared with control group. At morphology of skin, inflammation was decreased and the thickness of epidermis was well preserved in Sophorae Radix and Coptidis Rhizoma-iontophoresis group. Conclusion : Sophorae Radix and Coptidis Rhizoma-iontophoresis had some anti-allergy, anti-inflammatory effects on allergic contact dermatitis, but had no effects on melanin-erythema levels, pH levels and hydration levels of skin.

  • PDF

A Study on The Improvement of Profile Tilting or Bottom Distortion in HARC (높은 A/R의 콘택 산화막 에칭에서 바닥모양 변형 개선에 관한 연구)

  • Hwang, Won-Tae;Kim, Gli-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.389-395
    • /
    • 2005
  • The etching technology of the high aspect ratio contact(HARC) is necessary at the critical contact processes of semiconductor devices. Etching the $SiO_{2}$ contact hole with the sub-micron design rule in manufacturing VLSI devices, the unexpected phenomenon of 'profile tilting' or 'bottom distortion' is often observed. This makes a short circuit between neighboring contact holes, which causes to drop seriously the device yield. As the aspect ratio of contact holes increases, the high C/F ratio gases, $C_{4}F_{6}$, $C_{4}F_{8}$ and $C_{5}F_{8}$, become widely used in order to minimize the mask layer loss during the etching process. These gases provide abundant fluorocarbon polymer as well as high selectivity to the mask layer, and the polymer with high sticking yield accumulates at the top-wall of the contact hole. During the etch process, many electrons are accumulated around the asymmetric hole mouth to distort the electric field, and this distorts the ion trajectory arriving at the hole bottom. These ions with the distorted trajectory induce the deformation of the hole bottom, which is called 'profile tilting' or 'bottom distortion'. To prevent this phenomenon, three methods are suggested here. 1) Using lower C/F ratio gases, $CF_{4}$ or $C_{3}F_{8}$, the amount of the Polymer at the hole mouth is reduced to minimize the asymmetry of the hole top. 2) The number of the neighboring holes with equal distance is maximized to get the more symmetry of the oxygen distribution around the hole. 3) The dual frequency plasma source is used to release the excessive charge build-up at the hole mouth. From the suggested methods, we have obtained the nearly circular hole bottom, which Implies that the ion trajectory Incident on the hole bottom is symmetry.

Design and Meshing Analysis of a Non-involute Internal Gear for Counters (계수기용 비인벌류트 치형의 내치차 설계와 물림해석)

  • Lee, Sung-Chul
    • Tribology and Lubricants
    • /
    • v.30 no.4
    • /
    • pp.212-217
    • /
    • 2014
  • A counter gear transmits the rotation angle, so the angular velocity ratio of the gear does not necessarily need to be constant in the meshing process. As a pinion has a small number of teeth when combined with an internal gear for counters, tooth interference can occur with the use of an involute curve. This paper introduces circular arcs that represent a tooth profile and fillet for the profile design of a pinion through the combination of arcs with lines. The straight line of a rack tooth represents the profile of a mating internal gear. Thus, the circular arc and line maintain contact during the rotation of the counter gear. This paper presents an analysis of the meshing of the circular arc tooth and rack tooth along with the properties of the counter gear, such as the change in rotational velocity and amount of backlash. The contact ratio of the counter gear is 1 because the tooth contact occurs between circular arcs and line. The initial position of tooth contact, which denotes the simultaneous contact of two teeth, is found. As the rotation of the pinion, only one tooth keeps the contact situation. This meshing property is analyzed by the geometrical constraints of the tooth profile in contact and the results are presented as graphical diagrams in which tooth-arc movements are superimposed.