• Title/Summary/Keyword: Consumed-Power

Search Result 383, Processing Time 0.027 seconds

An Energy Harvesting Aware Routing Algorithm for Hierarchical Clustering Wireless Sensor Networks

  • Tang, Chaowei;Tan, Qian;Han, Yanni;An, Wei;Li, Haibo;Tang, Hui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.2
    • /
    • pp.504-521
    • /
    • 2016
  • Recently, energy harvesting technology has been integrated into wireless sensor networks to ameliorate the nodes' energy limitation problem. In theory, the wireless sensor node equipped with an energy harvesting module can work permanently until hardware failures happen. However, due to the change of power supply, the traditional hierarchical network routing protocol can not be effectively adopted in energy harvesting wireless sensor networks. In this paper, we improve the Low-Energy Adaptive Clustering Hierarchy (LEACH) protocol to make it suitable for the energy harvesting wireless sensor networks. Specifically, the cluster heads are selected according to the estimation of nodes' harvested energy and consumed energy. Preference is given to the nodes with high harvested energy while taking the energy consumption rate into account. The utilization of harvested energy is mathematically formulated as a max-min optimization problem which maximizes the minimum energy conservation of each node. We have proved that maximizing the minimum energy conservation is an NP-hard problem theoretically. Thus, a polynomial time algorithm has been proposed to derive the near-optimal performance. Extensive simulation results show that our proposed routing scheme outperforms previous works in terms of energy conservation and balanced distribution.

A Performance Measurement and Evaluation of a 400RT Vertical type Geothermal System installed in a Complex Building Before Occupancy (복합용도 건물에 적용된 400RT급 수직형 지열시스템의 입주전 성능평가)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho;Jung, Myoung-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.7-14
    • /
    • 2008
  • 400RT geothermal system which is the biggest capacity among on-operations at present in Korea is measured and evaluated on 23rd${\sim}$26th Jan. 2008 during those days building is not allowed owners and/or tenants to move in. The geothermal system is consist with vertical-typed 112 geothermal heat exchangers which are installed circle-like 1 row with 4m interval, and has 16 units of 25USRT geothermal-source heat pump(GSHP)s. And each 5 units of circulation pump are running for geothermal heat exchangers and hot water supplies. The followings are the results. The temperatures at G.L. -70m of 2 boreholes are varied quite similarly. The average temperature difference between inlet and outlet of geothermal pipes is $4.1^{\circ}C$, and that of hot water supply is $3.2^{\circ}C$, of Zone 3's each 4 GSHPs when being operated. Despite temperature fluctuations by heating loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $4.1^{\circ}C$. This study propose "Geothermal System COP" which includes not only consumed electric power by compressor but also circulation pumps and auxiliary utilities. By comparing the geothermal system COP with GSHP's performance specification, it is clear that the performances of GHSPs of this site are satisfied with the specification.

Convective Heat Loss from Solar Tower Receiver with Tilt Angles and Operating Conditions (Solar Tower용 흡수기의 설치 각도 및 작동 조건 변화에 따른 대류 열손실 분석)

  • Kang, Kyung-Mun;Lee, Ju-Han;Kim, Yong;Seo, Tae-Beom;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.121-128
    • /
    • 2007
  • Convective heat loss from solar tower receiver is experimentally investigated in wind tunnel with tilt angles and operating conditions. In order to simulate the receiver, an electric heater, which is made of aluminum (width : 100 mm, height : 100mm) is used and installed in the wind tunnel. The convective heat loss from the receiver is dependent on the direction and the velocity of the wind and the surface temperature of the receiver. The tilt angle and surface temperature of the receiver are varied from 0o (cavity facing straight down) and 90o(cavity aligned horizontally) and from $150^{\circ}C$ to $250^{\circ}C$, respectively. Also, the wind speed is changed from 0 to 4m/s. The convective heat loss is obtained by measuring consumed power to the heater to maintain the desired surface temperature. It is concluded that Nusselt number increases with increasing wind speed for all cases. Especially, it is showed that Nusselt number can be maximized when the tilt angle is 30o.

An Embedded Software Debugger Using an Instruction Set Simulator (명령어 집합 시뮬레이터를 이용한 임베디드 소프트웨어 디버거)

  • Jung, Hun;Son, Sung-Hoon;Shin, Dong-Ha
    • Journal of the Korea Society for Simulation
    • /
    • v.15 no.4
    • /
    • pp.51-58
    • /
    • 2006
  • Debugging embedded softwares is very different from debugging general softwares. For examples, debugging embedded software requires more information, such as information on power consumption, information on the distribution of executed instructions, information on the distribution of used registers, and information on the amount of clocks consumed during the execution of a program, that is not needed in debugging general softwares. In this paper, we propose more effective method fer debugging embedded softwares using an instruction set simulator for the microprocessor that is executing embedded softwares. In this research, we develop a debugger based on an instruction set simulator for a domestic embedded microprocessor called SE1608 and we shows an effective debugging method using a MiBench program which is widely used to benchmark embedded softwares. The debugging method proposed in this paper is relatively easy to implement and shows many advantages compared with existing debugging methods.

  • PDF

How Media Constitutes North Korean Female Defectors to Disparate Subject (감각적 사유와 이질적 주체 구성-종편의 탈북여성 재현의 정치)

  • Kim, Eunjune
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.772-780
    • /
    • 2016
  • This study examined the politics of representation about North Korean female defectors in general programming channels. In that channel's programs, the women are established as soften private people who got a lift in capitalism aggressively and as disparate subject that have value to be consumed by mass audience. They are caricatured with the testimony and internal competition, be emphasized that heterogeneous object. General programming channels use the women as easy and cheap substitutes for foreigners, also objectifies them to complies with the patriarchal authority. General programming channels are continuously producing a story to deal with North Korean female defectors in disparate subject. In this way, they owns the time and qualification to talk to the women as objects to be displayed, to ensure the media power. Ultimately, the female defectors is only a consumption subject that being sensuously staring, so they remain 'other' instead of 'us'.

DSP-Based Micro-Modem for Underwater Acoustic Communications (DSP 기반 초소형 수중 음향통신 모뎀)

  • Lee, Dongsoo;Lee, Sangmin;Park, Sung-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.3
    • /
    • pp.275-281
    • /
    • 2014
  • Recently, the need for various underwater application systems targeting efficient resource exploration and aquatic ecosystem monitoring is rapidly increasing in littoral sea and inland waters. In this paper, we focus on the research and development of digital module of acoustic micro modem which can be used for underwater mobile communication systems and underwater sensor network systems. Specifically, a digital module of acoustic modem embedding digital signal processor is designed and implemented. On top of the developed hardware platform, physical layer frame generation and recovery and channel coding algorithms are mounted and tested in a water tank and a pond to verify its functionality and performance. According to experimental results, less than 1 percent of total computational power is consumed in the processing of frame control and convolutional code with the data rate of 1 kbps. Thus, the performance of micro modem could be improved by loading efficient baseband algorithms into the processor while maintaining the implemented hardware.

Monitoring of the Carbon Emission and Energy Consumption of CVD and Etcher for Semiconductor Manufacturing (반도체 제조용 CVD 및 Etcher 장비의 탄소배출량과 에너지 소비량 모니터링)

  • Ko, Dong Guk;Bae, Sung Woo;Kim, Kwang Sun;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.3
    • /
    • pp.19-22
    • /
    • 2013
  • The purpose of this study is to develop a system that can monitor the amounts of energy consumption during CVD and etching process for semiconductor manufacturing. Specifically, this system is designed to measure the $CO_2$ emission amounts quantitatively by measuring the flow rate of gas used and amount of power consumed during the processes. The processes of CVD equipment can be classified generally into processing step and cleaning step and all the two steps were monitored. In CVD and etcher equipments, various gases including Ar and $O_2$ are used, but Ar, $O_2$ and He were monitored with the use of the LCI data of Korea Environmental Industry & Technology Institute and carbon emission coefficients of EcoInvent. As a result, it was found that the carbon emission amounts of CVD equipment for Ar, $O_2$ and He were $0.030kgCO_2/min$, $4.580{\times}10^{-3}kgCO_2/min$ and $6.817{\times}10^{-4}kgCO_2/min$, respectively and those of etcher equipment for Ar and $O_2$ are $5.111{\times}10^{-3}kgCO_2/min$ and $7.172kgCO_2/min$, respectively.

Numerical Analysis on the Effect of Corrugation Angle on the Performance of Humidifying Element (절곡각에 따른 가습소자의 성능에 대한 수치해석적 연구)

  • Lee, Eul-Jong;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3051-3059
    • /
    • 2015
  • In this study, the effect of corrugation angle on thermal performance of corrugated plate is numerically investigated with an aim to develop humidifying element. Numerical analysis was conducted for a range of corrugation angle (from $0^{\circ}/0^{\circ}$ to $60^{\circ}/60^{\circ}$ for equal angle and from $15^{\circ}/0^{\circ}$ to $15^{\circ}/60^{\circ}$ for unequal angle). Results revealed that both j and f factor increased as corrugation angle increased. Especially, f factor increased significantly at high corrugation angles. j and f factors of unequal angle plates and those of equal angle (obtained by averaging unequal angles) plates were approximately the same. The largest $j/f^{1/3}$, which implies the largest heat transfer rate per consumed power, was obtained at $15^{\circ}/15^{\circ}$. Existing correlations under- or over-predicted the present numerical results.

Study on Silica Removal from Borated Water Using Reverse Osmosis Membranes in Nuclear Power Plants (역삼투막의 선택적 제거특성을 이용한 원자력발전소 붕산수 중의 실리카 제거에 관한 연구)

  • 윤석원;박광규
    • Membrane Journal
    • /
    • v.7 no.4
    • /
    • pp.167-174
    • /
    • 1997
  • The concentration of silica is required to meet a certain level because silica affects fuel and materials integrity by forming a zeolite layer on fuel cladding surfaces. When the established Feed and Bleed method is employed, nuclear waste increase and the corresponding amount of boric acid is constantly consumed. This study concentrates on minimizing the amount of nuclear waste and consumption of boric acid. Using five different membranes, operating conditions such as temperatur, feed water flow rate, boric acid recovery and silica removal rate were examined. A silica-selective removal system was designed based on the above optimization procedures. Three-stage system was designed with two characteristically different membranes so that it could correspond with the different situation easily. Compared to the pevious results of the Feed and Bleed method, the current method showed that the amount of nuclear waste was reduced to 7%, and the consumption of boric acid to 15.7%.

  • PDF

Design of CAVLC Decoder for H.264/AVC (H.264/AVC용 CAVLC 디코더의 설계)

  • Jung, Duck-Young;Sonh, Seung-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1104-1114
    • /
    • 2007
  • Digital video compression technique has played an important role that enables efficient transmission and storage of multimedia data where bandwidth and storage space are limited. The new video coding standard, H.264/AVC, developed by Joint Video Team(JVT) significantly outperforms previous standards in compression performance. Especially, variable length code(VLC) plays a crucial pun in video and image compression applications. H.264/AVC standard adopted Context-based Adaptive Variable Length Coding(CAVLC) as the entropy coding method. CAVLC of H.264/AVC requires a large number of the memory accesses. This is a serious problem for applications such as DMB and video phone service because of the considerable amount of power that is consumed in accessing the memory. In order to overcome this problem in this paper, we propose a variable length technique that implements memory-free coeff_token, level, and run_before decoding based on arithmetic operations and using only 70% of the required memory at total_zero variable length decoding.