• 제목/요약/키워드: Construction Capacity

검색결과 2,815건 처리시간 0.031초

연약지반 표층처리공법 설계정수(지지력계수$N_c$, 인장력$T_i$) 산정방법에 관한 고찰 (A Study on Determining the Design Parameter ($N_c$, $T_i$) of the Surface Reinforcement Method for Soft Ground)

  • 함태규;서세관;조삼덕;양기석;유승경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.750-758
    • /
    • 2009
  • This study, as basic research which was intended to develope the surface reinforcement method using reinforcement material which is applicable to very soft ground in Korea, was aimed at proposing the design parameter for the surface ground improvement method. To that end, a wide width tensile test using geotextile, geogrid and steel bar (substitute for bamboo) and 25 kinds of the laboratory model tests with the end restraint conditions of the reinforcement that comprises the constrained and partially constrained (3 types) conditions were conducted. And the result indicated that the modulus of subgrade reaction or $N_c$ value (5.3) apparently overestimated the bearing capacity of very soft ground such as dredged ground. Moreover, as a result of model test by partially constraining the preload of 23.0kgf using geotextile, the effect of bearing capacity($q_1$) appeared to be the largest till the loading stress was $0.4tf/m^2$ due to cohesion, while it reached 75% of the maximum bearing force after $0.4tf/m^2$ due to increase in the effect of bearing capacity($q_2$) caused by the tensile force of the reinforcement. Such results tended to have appeared constantly or very similarly with each other, irrespective of the type of reinforcement (geogrid, steel bar) and constraint conditions.

  • PDF

현장시험을 통한 파형 마이크로파일의 시공성 및 거동 평가 (A Field Study on the Constructability and Performance Evaluation of Waveform Micropile)

  • 장영은;한진태
    • 한국지반공학회논문집
    • /
    • 제32권10호
    • /
    • pp.67-79
    • /
    • 2016
  • 파형 마이크로파일은 기존 마이크로파일과 제트 그라우팅 공법을 접목하여 그라우트체를 파형의 형상으로 시공하는 공법으로, 파형 구근에 의한 마찰저항 성능을 높여 마이크로파일의 지지력 및 경제성을 개선하기 위해 개발되었다. 본 연구에서는 파형 마이크로파일의 시공 타당성 및 지지성능 개선 효과를 검증하기 위해 총 2회의 현장시험을 수행하였다. 파형 마이크로파일의 시공성 분석을 위해 제트 그라우팅 공법을 활용하여 시간 및 압력 조절을 통한 파형 그라우트 형성 실험을 수행하고 지중 말뚝 굴착을 통해 파형 형성 여부를 확인하였다. 확인 결과, 제트 그라우팅의 압력 및 시간 조절을 통해 파형 마이크로파일의 요구 형상을 적절히 시공할 수 있는 것을 확인하였으며, 하중재하시험 결과에서는 전단키가 없는 마이크로파일과 비교해 파형 마이크로파일의 지지력이 형상에 따라 1.4 배에서 2.3배까지 증가해 파형 마이크로파일의 지지력 개선효과가 우수한 것으로 나타났다.

화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구 (Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant)

  • 이승재;조만영;김세용;김은태;강병욱;박한민;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

재해분석을 통한 농업토목공사의 공종별 위험성 평가 (Risk Assessment of Agricultural Construction Works using Accident Analysis and Analytic Hierarchy Process)

  • 양영진;오수훈;노재경
    • 한국농공학회논문집
    • /
    • 제60권4호
    • /
    • pp.15-25
    • /
    • 2018
  • The accident risk at the construction workplace associated with agricultural engineering is comparatively higher than those of other fields due mainly to its complex work types and processes. Agricultural engineering deals with a variety of agricultural infrastructures from irrigation and drainage facilities to giant-scale coastal reclamation land infrastructures. The characteristics that most agricultural projects have conducted on a small-scale even worsen the situation drawing low attentions to risk management. Therefore, systematical risk assessment that focuses on details of agricultural construction work process is required in order to enhance safety management capacity and to prevent repetitive accidents ultimately. This study aims to categorize construction work types and processes of agricultural construction works, and to quantitatively assess the accident risk of them based on accident analysis. Regarding classification of construction works, actual 827 accident cases were thoroughly reviewed and coded by their construction site, facility and work type, project scale and so on. Most accidents (71.8 % of total cases) occurred in small-scale construction workplaces with less than 5 billion Korean won project budget. And those accidents related to agricultural infrastructure project (37.4%) and agricultural water development project (22.4%). In terms of work types, accidents frequently took place in form-work followed by pipe installation work, steel bar work and concrete work. The potential risks were compared with actual outbreak of accidents based on Analytic Hierarchy Process (AHP). The results show that the potential conditions of accident expected to be took place is somewhat different from the actual conditions where accidents actually happened. This implicates that risk management manuals or education needs to be adjusted by reflecting unexpected circumstances. Overall, this study is meaningful in that the results could be foundations as to strengthen risk management capacity for agricultural engineering projects.

공동주택공사의 건설용 리프트를 이용한 양중계획 타당성 분석 (A Feasibility Study on Optimal Lifting Planning in the High-rise Apartment Building Construction)

  • 이준복;한충희
    • 한국건설관리학회논문집
    • /
    • 제9권3호
    • /
    • pp.185-193
    • /
    • 2008
  • 점차 대형화, 고층화되고 있는 공동주택공사에서 작업효율성을 향상시키고자 양중작업의 최적화를 위한 리프트 선정방식의 합리적 절차와 기준이 요구되고 있다. 따라서, 작업효율성 및 경제적 측면에서의 분석을 통하여 양중자재의 종류 및 규격, 건축물의 높이, 공사기간에 따른 건설용 리프트의 합리적 선정 및 운영을 위한 기준을 제시할 필요가 있다. 본 연구의 목적은 고층화 복잡화되고 있는 공동주택건설 현장여건에 따른 효율적 양중계획 및 관리를 위하여 대표적인 양중장비인 저속형과 중속형 리프트의 작업효율성과 경제성의 비교 분석을 통하여 최적의 선정을 위한 기초적 자료를 제시하는 것이다. 본 연구의 주요 결과는 40층 기준으로 중속형 리프트가 저속형에 비해 약 43%의 작업효율이 높은 것으로 분석되었다. 본 연구의 결과는 향후 공사의 용도, 규모, 형태, 조건 등에 알맞은 건설용 리프트 선정 기준/지침/규정을 마련하는 연구의 기초자료로 활용될 것으로 기대된다.

Critical Factors of Subcontractor Evaluation and Selection: A Case Study in Vietnam

  • VO, Khoa Dang;PHAM, Cuong Phu;PHAN, Phuong Thanh;VU, Ngoc Bich;DUONG, My Tien Ha;LE, Loan Phuc;NGUYEN, Quyen Le Hoang Thuy To
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권3호
    • /
    • pp.297-305
    • /
    • 2021
  • A contractor or a main contractor is a company with full capacity to construct all project's works for the owner. A subcontractor is an organization that works with the main contractor to execute and complete work packages for the project. Selecting an effective subcontractor will help the efficiency and success of any projects in the construction industry. Therefore, this study identified subcontractor evaluation factors in Vietnam by collecting questionnaire survey data from engineers and staffs in the construction industry project environment. An exploratory factor analysis (EFA) was then performed to identify the critical factors when evaluating and selecting the subcontractor in construction projects. Moreover, when considering the impact level in terms of the average value, the research results showed that the most critical concern was the subcontractor's reputation. Furthermore, the top five factors affecting the sub-contractor evaluation and selection are (i) reputation, (ii) price, (iii) construction techniques, (iv) ability to implement projects according to commitments, and (v) subcontractor competence (the team of workers, technician staff, engineers with full capacity according to regulations). These research results provide an overall perspective that will help main contractors develop suitable subcontractors' evaluation and selection factors in their projects in the construction industry.

Analysis of stability control and the adapted ways for building tunnel anchors and a down-passing tunnel

  • Xiaohan Zhou;Xinrong Liu;Yu Xiao;Ninghui Liang;Yangyang Yang;Yafeng Han;Zhongping Yang
    • Geomechanics and Engineering
    • /
    • 제35권4호
    • /
    • pp.395-409
    • /
    • 2023
  • Long-span suspension bridges have tunnel anchor systems to maintain stable cables. More investigations are required to determine how closely tunnel excavation beneath the tunnel anchor impacts the stability of the tunnel anchor. In order to investigate the impact of the adjacent tunnel's excavation on the stability of the tunnel anchor, a large-span suspension bridge tunnel anchor is utilised as an example in a three-dimensional numerical simulation approach. In order to explore the deformation control mechanism, orthogonal tests are employed to pinpoint the major impacting elements. The construction of an advanced pipe shed, strengthening the primary support. Moreover, according to the findings the grouting reinforcement of the surrounding rock, have a significant control effect on the settlement of the tunnel vault and plug body. However, reducing the lag distance of the secondary lining does not have such big influence. The greatest way to control tunnel vault settling is to use the grout reinforcement, which increases the bearing capacity and strength of the surrounding rock. This greatly minimizes the size of the tunnel excavation disturbance area. Advanced pipe shed can not only increase the surrounding rock's bearing capacity at the pipe shed, but can also prevent the tunnel vault from connecting with the disturbance area at the bottom of the anchorage tunnel, reduce the range of shear failure area outside the anchorage tunnel, and have the best impact on the plug body's settlement control.

집합건축물의 리모델링과 보수$\cdot$보강 사례연구 (A Case Study on the Remodeling and Repair/Rehabilitation of the Multi-Owned Buildings)

  • 정은철;정혜교;이희석;김승진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.219-222
    • /
    • 2005
  • Recently, remodeling has been a major field of the building construction that comes up for the alternatives of the reconstruction and the economical construction method. In the almost cases, the engineering capacity for the repair/rehabilitation of the remodeling should satisfy also the owner's various needs (eg, the minimum construction time, etc.) and the safety of the building. Also, the engineering and construction technique for remodeling should be applied to the contrary point of view of the general construction method. But, the many problem actually has arose from the wrongly applied construction method that is caused with the insufficient researches and development. Therefore, this study would suggest the necessities and the directions of developing the elementary engineering technique and the method that satisfy the owner's various needs for the remodeling and repair/rehabilitation of the multi-owned building as multiplex shop, with the successful construction cases.

  • PDF

모듈러 건설의 운송계획 최적화를 위한 시뮬레이션 모델 개발 (Development of Simulation Model for Optimization of Modular Construction Transportation Plan)

  • 김현민;권우빈;안희재;조훈희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.200-201
    • /
    • 2022
  • Off-Site Construction is being widely adopted as an alternative to solve endemic problems in construction industry such as low productivity and efficiency. However, it is strongly recommended to examine the transportation process to be optimized because it determines the size of a modular and influences the cost of the construction. Therefore, in this study simulation model for optimization of modular construction transportation plan was developed using AnyLogic. As a result of the study, the influence of trailer transport capacity and transport time increases as the number of modular which should be transported from factory to site increases.

  • PDF

Numerical study of concrete-encased CFST under preload followed by sustained service load

  • Li, Gen;Hou, Chao;Han, Lin-Hai;Shen, Luming
    • Steel and Composite Structures
    • /
    • 제35권1호
    • /
    • pp.93-109
    • /
    • 2020
  • Developed from conventional concrete filled steel tubular (CFST) members, concrete-encased CFST has attracted growing attention in building and bridge practices. In actual construction, the inner CFST is erected prior to the casting of the outer reinforced concrete part to support the construction preload, after which the whole composite member is under sustained service load. The complex loading sequence leads to highly nonlinear material interaction and consequently complicated structural performance. This paper studies the full-range behaviour of concrete-encased CFST columns with initial preload on inner CFST followed by sustained service load over the whole composite section. Validated against the reported data obtained from specifically designed tests, a finite element analysis model is developed to investigate the detailed structural behaviour in terms of ultimate strength, load distribution, material interaction and strain development. Parametric analysis is then carried out to evaluate the impact of significant factors on the structural behaviour of the composite columns. Finally, a simplified design method for estimating the sectional capacity of concrete-encased CFST is proposed, with the combined influences of construction preload and sustained service load being taken into account. The feasibility of the developed method is validated against both the test data and the simulation results.