• Title/Summary/Keyword: Constraints to the Transmission

Search Result 292, Processing Time 0.032 seconds

Assessment Software of Harmonic Emission Limits for Transmission System (송전계통 고조파 방출 한계 평가 소프트웨어)

  • Wang, Y.P.;Jeong, J.W.;Jeong, D.I.;Kwak, N.H.;Jeon, Y.S.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.563-564
    • /
    • 2007
  • In recent years, equipment and network standards have been increasing in both number and complexity. Two standards that will soon be introduced to KOREA are the HV standards for assessing distorting and fluctuating loads, IEC 61000-3-6. Utility engineers, being under increasing time constraints, are turning more and more to software to quickly solve problems. This paper describes the methodology used to implement the above standards in Microsoft Excel in order to assist utility engineers to readily apply these standards in practical situations.

  • PDF

A Study on the Outage Cost Assessment by using Macro Approach (거시적인 접근방법을 통한 공급지장비 추정에 관한 연구)

  • Park, Young-Shin;Jeon, Dong-Hoon;Park, Jeong-Je;Oh, Tae-Gon;Cho, Kyeong-Hee;Choi, Jae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1703-1711
    • /
    • 2010
  • Electric power utilities are facing increasing uncertainties regarding the economic, political, societal, environmental constraints under they operate and plan their future systems. The utilities have to integrate consumers' interruption cost representing reliability worth of electricity into the process of determining the optimum investment level. In order to do so, the estimated outage cost must be included into quantitative index corresponding to system capital and operation investment cost to establish an optimal expansion plan. This paper is a study on the outage cost assessment by using macro approach for calculating IEAR(Interrupted Energy Assessment Rates) and the TRELSS(Transmission Reliability Evaluation for Large-Scale Systems) program was used to calculate EENS(Expected Energy Not Served).

Discrete Optimal Design of Truss Structure Using Genetic Algorithm (GA를 이응한 트러스 구조물의 이산최적설계)

  • 황선일;조홍동;이상근;한상훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.301-308
    • /
    • 1999
  • This paper describes the application of genetic algorithm(GA) in the discrete optimal design of truss structures. Stochastic processes generate an intial population of design and then apply principles of natural selection/survival of the fittest to improve the design. GA is applied to minimum weight of truss subject to stress and displacement constraints under multiple loading conditions. First, optimum solutions obtained from GA are compared to verify the reliability of GA with m well-known transmission tower structure which is referred to by other authors. Then, discrete optimal design is performed in satisfying service conditions of truss structure with commercially available fabricated sizes. From the results, it is found that GA search technique is very effective for discrete optimal design of truss structure and has high robustness.

  • PDF

Congestion management Using Phase-Shifting Transformer in Power Systems (Phase-Shifting Transformer를 이용한 계통 혼잡처리 방안)

  • Kim, Kyu-Ho;Shin, Ho-Sung;Song, Kyung-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.822-824
    • /
    • 2005
  • This paper presents a scheme to solve the congestion problem using phase-shifting transformer(PST) in power systems. Available transfer capability(ATC) is an important indicator of the usable amount of transmission capacity accessible by several parties for commercial trading in power transaction activities. This paper deals with an application of optimization technique for ATC calculation. Sequential quadratic programming(SQP) is used to maximize power flow of tie line subject to security constraints such as voltage magnitude and real power flow. The proposed method is applied to 10 machines 39 buses model systems to show its effectiveness.

  • PDF

Neural Network Application to the T/L Operation for Suppression of Short Circuit Capacity (고장용량 감소를 위한 송전선 개방 운용에 신경회로망 적용 연구)

  • Lee, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.26-30
    • /
    • 2000
  • Switching of the transmission lines(T/L) is one of the methods for wuppressing the short circuit capacity. This paper presents the T/L switching operation by using the Hopfield neural network(HNN). The switching of T/L can make the line powers and the bus voltages deteriorated, as well as the fault current decreased. Such an insecure state should be avoided when the T/L is operated to be open. In this studies, the inequality constraints are formulated into the objective function to be incorporated with the HNN. Test results show that the convergence characteristics of HNN lead to the adequate solution of T/L switching.

  • PDF

Optimal technique of cost function for FACTS operation in power system using Lagrange Multipliers (라그랑지 승수를 사용한 계통의 FACTS 기기 설치비용 함수의 최적화 기법)

  • Park Seong Wook;Baek Young Sik;Seo Bo Hyeok
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.15-17
    • /
    • 2004
  • The flexible AC transmissions system (FACTS) is the underpinning concept upon which are based promising means to avoid effectively power flow bottlenecks and ways to extend the loadability of existing power transmission networks. This paper proposes a method by which the optimal locations of the FACTS to be installed in power system under cost function. The optimal solution of this type of problem requires large scale nonlinear optimisation techniques. We used Lagrange multipliers to solve a nonlinear equation with equality and ineaquality constraints. Case studies on the standard IEEE 14 bus system show that the method can be implemented successfully and that it is effective for determining the optimal location of the FACTS

  • PDF

Optimal location of FACTS controller for power flow (전력흐름 제어를 위한 FACTS 제어기의 위치 선정)

  • Park, Seong-Wook;Seo, Bo-Hyeok;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.16-18
    • /
    • 2004
  • The flexible AC transmissions system (FACTS) is the underpinning concept upon which are based promising means to avoid effectively power flow bottlenecks and ways to extend the loadability of existing power transmission networks. This paper proposes a method by which the optimal locations of the FACTS to be installed in power system under cost function. The optimal solution of this type of problem requires large scale nonlinear optimization techniques. We used Lagrange multipliers to solve a nonlinear equation with equality and ineaquality constraints. Case studies on the standard IEEE 14 bus system show that the method can be implemented successfully and that it is effective for determining the optimal location of the FACTS.

  • PDF

Design and Analysis of Two-Axis Stage Driven by Piezoelectric elements (피에조 구동형 2축 스테이지의 설계 및 해석)

  • 류성훈;한창수;최기봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.742-745
    • /
    • 2003
  • Piezoelectric elements driven ultra-precision stages have been used for high accuracy, fast response and high load rapacity. which are allowable to apply the stages to AFMs. Most of the piezoelectric driven stages are guided by flexure hinges for force transmission and mechanical amplification. However the flexure hinge mechanisms cause lack of position accuracy due to coupled and parasitic motions. Hence it is important that the mechanism design of the stage is focused on the stiffness of the flexure hinges to accomplish fast response and hish accuracy without the coupled and parasitic motions. In this study, some constraints for optimal design of a piezoelectric elements driven stage and a design method are proposed. Next, an optimal design is carried out using mathematical calculation. Finally the designed results are verified by FEM.

  • PDF

Optimal Dispatch of Reactive Power considering discrete VAR using Genetic Algorithms (유전알고리즘을 이용하여 무효전력원의 이산성을 고려한 무효전력 최적배분)

  • You, Seok-Ku;Kim, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.571-573
    • /
    • 1995
  • This paper presents a method for optimal dispatch which minimizes transmission losses and improves voltage profile of power systems using genetic algorithm based on the mechanism of natural genetics and natural selection. The constraints are VAR sources(transformer tap, generator voltage magnitude and shunt capacitor/reactor), load bus voltages and generator reactive power. Real variable-based genetic algorithms which can save coding times and maintain the accuracy are applied for optimal dispatch of reactive power. The genes of genetic algorithm consisted of integers for considering discrete VAR sources. A efficient operator for crossover is proposed to consider the effect of close genes. The algorithm proposed can apply to problems for large scale power systems with multi-variables and complex nonlinear functions efficiently. The proposed method is applied to IEEE 30 buses model system to show its effectiveness.

  • PDF

A Study on the Optimal Operation of 2010 Summer Peak in Korea Power System (2010년 여름철 전력계통 최적 운영에 관한 연구)

  • Lee, Sung-Moo;Cho, Jong-Man;Kim, Kyu-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1733-1740
    • /
    • 2010
  • KPX(Korea Power Exchange) predicts that summer peak load will be 70,700MW and system overload will be 150% from contingency analysis. This paper presents a method to operate power system at 2010 summer peak. about equipment variation, power system variation, analysis results of voltage stability, and the method to relief overload by comparing 2009 and 2010. Especially, transmission constraints to prevent global contingency in Korea power system and the role of SPS(Special Protection System) to prevent voltage collapse when fault occurs are introduced.