• 제목/요약/키워드: Constant power area

검색결과 148건 처리시간 0.027초

Adaptive Variable Angle Control in Switched Reluctance Motor Drives for Electric Vehicle Applications

  • Cheng, He;Chen, Hao;Xu, Shaohui;Yang, Shunyao
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1512-1522
    • /
    • 2017
  • Switched reluctance motor (SRM) is suitable for electric vehicle (EV) applications with the advantages of simple structure, good overload capability, and inherent fault-tolerance performance. The SRM dynamic simulation model is built based on torque, voltage, and flux linkage equations. The EV model is built on the basis of the analysis of forces acting on a vehicle. The entire speed range of the SRM drive is then divided into constant torque and constant power areas. The command torque of the motor drive system is given according to the accelerator pedal coefficient and motor operation areas. A novel adaptive variable angle control is proposed to avoid the switching chattering between the current chopping control and angle position control modes in SRM drives for EV applications. Finally, simulation analysis and experimental results are conducted to verify the accuracy of the proposed simulation model and control strategy.

A novel analytical approach for advection diffusion equation for radionuclide release from an area source

  • Esmail, S.;Agrawal, P.;Aly, Shaban
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.819-826
    • /
    • 2020
  • The method of the Laplace transform has been used to obtain an analytical solution of the three-dimensional steady state advection diffusion equation for the airborne radionuclide release from any nuclear installation such as the power reactor in an area source. The present treatment takes into account the removal of the pollutants through the nuclear reaction. We assume that the pollutants are emitted as a constant rate from the area source. This physical consideration is achieved by assuming that the vertical eddy diffusivity coefficient should be a constant. The prevailing wind speed is a constant in 𝑥- direction and a linear function of the vertical height z. The present model calculations are compared with the other models and the available data of the atmospheric dispersion experiments that were carried out in the nuclear power plant of Angra dos Reis (Brazil). The results show that the present treatment performs well as the analytical dispersion model and there is a good agreement between the values computed by our model and the observed data.

전력계통에서 동조탐색과 광역진동해석 (Analysis of Global Oscillation via Sync Search in Power Systems)

  • 심관식;남해곤;김용구;문영환;김상태
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1255-1262
    • /
    • 2009
  • The present study explained the phenomenon that low frequency oscillation is synchronized with discrete data obtained from a wide area system, and a sync search method. When a disturbance occurs in an power system, various controllers operate in order to maintain synchronization. If the system's damping is poor, low frequency oscillations continue for a long time and the oscillations are synchronized with one another at specific frequency. The present study estimated dominant modes, magnitude and phase of signals by applying parameter estimation methods to discrete signals obtained from an power system, and performed sync search among wide area signals by comparing the estimated data. Sync search was performed by selecting those with the same frequency and damping constant from dominant oscillation modes included in a large number of signals, and comparing their magnitude and phase. In addition, we defined sync indexes in order to indicate the degree of sync between areas in a wide area system. Furthermore, we proposed a wide area sync search method by normalizing mode magnitude in discrete data obtained from critical generator of the wide area. By applying the sync search method and sync indexes proposed in this study to two area systems, we demonstrated that sync scanning can be performed for discrete signals obtained from power systems.

고정계수 곱셈을 위한 비트패턴 전용덧셈기 설계 (Design of Bit-Pattern Specialized Adder for Constant Multiplication)

  • 조경주;김용은
    • 한국정보통신학회논문지
    • /
    • 제12권11호
    • /
    • pp.2039-2044
    • /
    • 2008
  • FIR 필터, DCT, FFT와 같은 디지털 신호처리 응용에서 다중 고정 계수 곱셈의 효율적인 하드웨어 구현문제에 자주 접하게 된다. 고정계수 곱셈기 설계에서 공통 하위식 제거 알고리즘은 면적과 전력소모를 상당히 개선시킬 수 있는 방법을 제공한다. 본 논문에서는 CSD 계수에서 빈번히 나타나는 두 공통 하위식($10{\bar{1}}$, 101)의 덧셈을 수행하는 전용덧셈기 설계 방법을 제안한다. 제안한 방법을 radix-24 FFT 구조의 고정계수 곱셈블록에 적용한 실험에서 제안한 방법의 면적, 지연시간, 전력소비는 기존방법 보다 각각 21%, 11%, 12% 정도 향상됨을 보인다.

효율적인 4-2 Compressor와 보상 특성을 갖는 근사 곱셈기 (Approximate Multiplier With Efficient 4-2 Compressor and Compensation Characteristic)

  • 김석;서호성;김수;김대익
    • 한국전자통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.173-180
    • /
    • 2022
  • 근사 컴퓨팅은 효율적인 하드웨어 컴퓨팅 시스템을 설계하기 위한 유망한 방법이다. 근사 곱셈은 고성능, 저전력 컴퓨팅을 위한 근사 계산 방식에 사용되는 핵심적인 연산이다. 근사 4-2 compressor는 근사 곱셈을 위한 효율적인 하드웨어 회로를 구현할 수 있다. 본 논문에서는 저면적, 저전력 특성을 갖는 근사 곱셈기를 제안하였다. 근사 곱셈기 구조는 정확한 영역, 근사 영역, 상수 수정 영역의 세 영역으로 나누어진다. 새로운 4:2 근사 compressor를 사용하여 근사 영역의 부분 곱 축소를 단순화하고, 간단한 오류 수정 방식을 사용하여 근사로 인한 오류를 보상한다. 상수 수정 영역은 오차를 줄이기 위해 확률 분석을 통한 상수를 사용하였다. 8×8 곱셈기에 대한 실험 결과, 제안한 근사 곱셈기는 기존의 4-2 compressor 기반의 근사 곱셈기보다 적은 면적을 요구하면서 적은 전력을 소비함을 보였다.

터보 냉동기용 핀 튜브에 관한 연구 (III) -압력 손실에 관하여- (A Study on Finned Tube Used in Turbo Refrigerator(III) -for Pressure Drop-)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제6권1호
    • /
    • pp.58-76
    • /
    • 1994
  • Heat transfer and pressure drop measurements are made on low integral-fin tubes in turbulent water flow condition. The integral-fin tubes investigated in this paper are nominally 19mm in diameter. Eight tubes have been used with trapezoidally shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. Plain tube having same diameter as finned tube is also tested for comparison. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken on steady state. The heat transfer loop is used for testing single long tubes and cooling water is pumped from a storage tank through filters and flowmeters to the horizontal test section where it is heated by steam condensing on the outside of the tube. The pressure drop across the test section is measured by means of pressure gauge and manometer. Each tube tested is cleaned with sodium dichromate pickling solution and well rinsed with water prior to installation in the test section. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, heat transfer of finned tube is enhanced up to 4 times as that of a plain tube at constant Reynolds number and up to 2 times at constant pumping power. 2. Friction factors are up to 1.6~2.1 times those of plain tube. 3. At a given Reynolds number, Nusselt number decrease with increasing pitch to diameter. 4. The constant pumping power ratio for low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio.

  • PDF

발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구 (A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop)

  • 김학만;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

A Low-area and Low-power 512-point Pipelined FFT Design Using Radix-24-23 for OFDM Applications

  • Yu, Jian;Cho, Kyung-Ju
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.475-480
    • /
    • 2018
  • In OFDM-based systems, FFT is a critical component since it occupies large area and consumes more power. In this paper, we present a low hardware-cost and low power 512-point pipelined FFT design method for OFDM applications. To reduce the number of twiddle factors and to choose simple design architecture, the radix-$2^4-2^3$ algorithm are exploited. For twiddle factor multiplication, we propose a new canonical signed digit (CSD) complex multiplier design method to minimize the hardware-cost. In hardware implementation with Intel FPGA, the proposed FFT design achieves more than about 28% reduction in gate count and 18% reduction in power consumption compared to the previous approaches.

Energy-aware Management in Wireless Body Area Network System

  • Zhang, Xu;Xia, Ying;Luo, Shiyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권5호
    • /
    • pp.949-966
    • /
    • 2013
  • Recently, Wireless Body Area Network (WBAN) has promise to revolutionize human daily life. The need for multiple sensors and constant monitoring lead these systems to be energy hungry and expensive with short operating lifetimes. In this paper, we offer a review of existing work of WBAN and focus on energy-aware management in it. We emphasize that nodes computation, wireless communication, topology deployment and energy scavenging are main domains for making a long-lived WBAN. We study the popular power management technique Dynamic Voltage and Frequency Scaling (DVFS) and identify the impact of slack time in Dynamic Power Management (DPM), and finally propose an enhanced dynamic power management method to schedule scaled jobs at slack time with the goal of saving energy and keeping system reliability. Theoretical and experimental evaluations exhibit the effectiveness and efficiency of the proposed method.

중.저온형 고체산화물 연료전지에서 연료로 공급되는 CO 와 H2 가 성능에 미치는 영향 (Performance Behavior by H2 and CO as a Fuel in Intermediate Temperature Solid Oxide Fuel Cell (IT-SOFC))

  • 박광진;배중면
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.963-969
    • /
    • 2008
  • The performance behavior of solid oxide fuel cell using $H_2$ and CO as fuels was investigated. The power densities and impedance results showed a little variation as the ratio of $H_2$ and CO changed. However, when the pure CO was used as a fuel, area specific resistance (ASR), especially low frequency region, was increased. This might be due to carbon deposition on anode. The maximum power density was 60% lower using CO than using $H_2$. Carbon deposition reduced after constant current was applied. The SOFC performance was recovered from the carbon deposition after applying constant current during 100h.