• 제목/요약/키워드: Constant frequency

검색결과 2,447건 처리시간 0.033초

우리나라 계통의 주파수응답특성에 의한 발전기정수 산정에 관한 연구 (Assessment of the Generators Constant from Frequency Response Properties of Korean Power System)

  • 정봉상;전영환;김일동;양정재
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.688-693
    • /
    • 2009
  • The response characteristics of power system frequency are determined by generator droop characteristics and load damping properties. The characteristics of governor droops are termed by generators constant, while those of load damping by load constant. In this paper, the generator constant and the load constant are assessed by measured data at the event of generator trips.

Microcomputer에 의한 3상유도전동기의 속도제어에 관한 연구

  • 정연택;이사영
    • 전기의세계
    • /
    • 제31권4호
    • /
    • pp.303-307
    • /
    • 1982
  • This paper describes how to improve a induction moter efficiency by a slip frequency control. Digital filter controlled by microcomputer is introduced in control system of a constant speed-drive and it has prove that the moter can be drived with a high efficiency at a constant slip frequency. The constant slip frequency control method has a merit of simplness.

  • PDF

중금속으로 오염된 포화사질토의 저주파대에서의 유전특성

  • 방선영;오명학;김용성;박준범
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.289-292
    • /
    • 2003
  • Laboratory tests were performed to investigate the dielectric property of saturated sands contaminated by heavy metals solution at low frequency. Differences of contamination and the real part of dielectric constant depend on heavy metal concentration was measured at low frequency, 100KHz below. The optimal frequency to develop the detection potentials of monitoring was 1KHz, 10KHz, 100KHz. At this frequency, Heavy metal contamination of saturated sands contamination can be recommended by analysis of complex dielectric constant.

  • PDF

매립지 침출수로 오염된 토양의 측정주파수에 따른 유전특성 변화 (Complex Dielectric Constant of Soil Contaminated by Landfill Leachate with Measured Frequency)

  • 오명학;방선영;박준범;이주형;이석헌;안규홍
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제9권3호
    • /
    • pp.1-11
    • /
    • 2004
  • 매립지 침출수로 오염된 지반의 오염도 조사에 유전상수 측정기법의 적용성을 평가하기 위하여 매립지 침출수로 오염된 간극수를 포함한 사질토 지반의 유전특성을 분석하였다. 본 연구에서는 75kHz-12MHz 범위의 주파수에서 유전 상수를 실수부와 허수부로 구분하여 분석을 수행하였다. 유전상수 실수부는 공간전하분극과 배향분극의 발현정도에 영향을 받기 때문에 침출수 농도가 증가함에 따라 저주파 영역에서는 유전상수의 실수부 값이 증가하는 경향을 나타내었으나, 고주파 영역에서는 감소하는 경향을 나타내었다. 유전상수 허수부의 경우에는 측정 주파수에 관계없이 침출수의 농도가 증가함에 따라 전류전도에 의한 에너지 손실량이 증대되어 유전상수 허수부가 증가하는 경향을 나타내었다. 유전상수의 실수부와 허수부가 간극수 내 침출수 농도에 따라 변하는 것에 기초하여 유전상수 측정기법이 침출수로 오염된 지반의 오염도 평가에 효과적으로 적용될 수 있음을 확인하였다.

수분함량과 측정주파수에 따른 사질토 지반의 유전상수 변화 (Variation of Dielectric Constant of Sand due to Water Content and Measuring Frequency)

  • 이주형;오명학;박준범;김형석
    • 한국지반공학회논문집
    • /
    • 제18권6호
    • /
    • pp.129-139
    • /
    • 2002
  • 최근 지반 특성과 지반 오염도의 조사를 위해 유전상수 측정기법을 적용하기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 다양한 함수비와 건조단위중량을 갖는 화강풍화토와 주문진표준사의 유전상수를 75kHz~12MHz의 주파수 범위에서 측정하였다. 사질토의 유전상수는 주파수가 증가함에 따라 감소하는 분산거동을 보였다. 또한 함수 비나 건조단위중량이 증가함에 따라 배향분극에 기여하는 물분자의 양이 증가하고 유전상수가 1인 공기의 양이 감소하여 유전상수가 증가하였다. 흙의 유전특성은 함수비와 건조단위중량을 모두 고려한 수분밀도에 선형적으로 비례하는 경향을 나타내었다. Maxwell식, Topp식, CRIM식에 의한 계산값과 측정된 값을 비교한 결과 기존의 식은 유전상수의 분산거동을 고려하지 못하고 있기 때문에 저주파에서는 측정값과 차이를 나타내었다.

수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성 (Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content)

  • 최종혁;차응석;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.98-104
    • /
    • 2010
  • 고주파수성분을 포함하는 뇌격전류나 또는 고장전류에 대한 접지시스템의 성능을 평가하기 위해 접지저항보다는 접지임피던스에 대한 고려가 필요하다. 접지임피던스를 평가하기 위해서는 토양의 저항률과 비유전율의 주파수의존성이 규명되어야 한다. 본 논문은 3가지 다른 토양에 대하여 수분함유량에 따른 저항률과 비유전율의 주파수의존성을 나타낸다. 결론적으로 토양의 저항률은 수분함유량이 증가함에 따라서 작아지게 되고, 1[MHz]보다 낮은 주파수에서 거의 변화하지 않으며 1[MHz]이상의 주파수에서는 감소한다. 반면에 비유전율은 1[MHz]이하의 주파수에서 매우 급격하게 감소하며, 1[MHz]이상의 주파수에서는 거의 변화하지 않는 것으로 나타났다. 본 실험 결과로 부터 낙뢰 또는 개폐서지에 대한 보호를 목적으로하는 접지시스템의 설계시 토양의 저항률과 비유전율을 고려하는 것이 바람직한 것으로 밝혀졌다.

모래의 수분함유량에 따른 비저항 및 비유전율의 주파수 의존성 (Frequency Dependent Resistivity and Relative Dielectric Constant with the Water Contents in Sand)

  • 이복희;차응석;최종혁;최영철;유양우;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.348-351
    • /
    • 2009
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than its ground resistance. Recently, some researches on the evaluation and modeling of the grounding impedances have been carried out but the results have not been yet sufficient. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of sand associated with water contents. As a result, the resistivity of sand is getting lower with increasing water content and it is nearly independent on the frequency in the range of less than 1MHz, and is decreased over the frequency range of above 1MHz. Also, the relative dielectric constant is rapidly decreased with the frequency in the range of less than 10kHz, but it is nearly not dependent on the frequency over the frequency range of 10kHz. It was found from this work that the frequency dependance of resistivity and relative dielectric constant of soil should be considered in designing the grounding systems for protection against lightning or surges.

  • PDF

전송선형 $90^{\cire}$ 정위상기에 관한 연구 (A Study on $90^{\cire}$ Constant Phase Shifter)

  • 이충웅
    • 대한전자공학회논문지
    • /
    • 제13권6호
    • /
    • pp.12-15
    • /
    • 1976
  • 본논문은 현재 AF주파수변역에서 90° 정위상기를 실현하고 있는 방법과는 전혀 다른 착상으로 VHF 고파수대에서 90° 정위상기를 실현하는 새로운 방법을 제시하였다. 이 90° 정위상기의 구조는 간단하며 분포정수소자인 전송선과 집중정수소자인 R.L.C로 용이하게 실현된다. This paper presents the realization method of 90° constant phase shifter in the VHF band, constructed by the entirely differens idea from the conventional method of the realization of constant phase shifter in the audio frequency range. The construction of 90° constant phase shifter is. simple and can be easily realized by using the distributed constant element, transmission line, and the lumped constant elements, R,C,L.

  • PDF

스크린 인쇄 기법에 의해 제작된 옥외 광고용 분산형 무기 EL 램프의 색좌표 변화와 광고 효과 (Effects of Advertising according to the Altering Color Coordinates of the Outdoor Billboards a Inorganic Powder EL Lamp That was made by Screen Printing Technique)

  • 문길환;이광숙
    • 한국인쇄학회지
    • /
    • 제30권1호
    • /
    • pp.47-58
    • /
    • 2012
  • The inorganic powder EL lamp was made by screen printing technique with a phosphor ink and a dielectric ink. Value of color coordinates X and Y increased under the condition of supplying driving power to the inorganic powder EL lamp and changing voltage with constant frequency. When frequency was changed under the constant voltage, value of color coordinates X and Y were decreased with increasing frequency. However, level of change of color coordinates X was different from color coordinates Y. When voltage was increased under constant frequency, changing degree of color coordinates X and Y shows similarity. But under the constant voltage with changing frequency, color coordinates X and Y were differently changed that degree of change of color coordinates Y showed five times more than that of color coordinates X. As increasing thickness of phosphor ink and dielectric ink, level of voltage and frequency, color coordinates X and Y were slightly changed. According to the thickness of phosphor ink and dielectric ink, and level of voltage and frequency, color coordinate of color light was changed. Frequency was most important element influencing on the change of color coordinate.

스크린 인쇄 기법에 의해 제작된 분산형 무기 EL 램프의 휘도 변화율 (The Altering Ratio of the luminance of a Inorganic Powder EL Lamp That was made by Screen Printing Technique)

  • 강영립;문길환
    • 한국인쇄학회지
    • /
    • 제29권2호
    • /
    • pp.33-44
    • /
    • 2011
  • The inorganic powder EL lamp was made by screen printing technique with a phosphor ink and a dielectric ink. The thickness of a phosphor ink layer and a dielectric ink layer is $35{\mu}m$ and $54{\mu}m$ respectively. A increasing ratio of the luminance of inorganic powder EL lamp to be a 1P1PD-phosphor ink layer in which increased voltage at constant frequency is higher 12% than when increased frequency at constant voltage. It is higher 57% than when increased frequency at constant voltage that the rate of increase of the luminance of inorganic powder EL lamp to be a 2PD-phosphor ink layer in which increased voltage at constant frequency. Finally, when increased voltage at constant frequency, a increasing ratio of the luminance of inorganic powder EL lamp to be a 2PD-phosphor ink layer is higher about 40% than that to be a 1P1PD-phosphor ink layer.