• 제목/요약/키워드: Constant current test

검색결과 274건 처리시간 0.028초

지속적인 직류자극이 토끼 비골 골절의 신생골 형성에 미치는 영향 (The Effects of Constant Direct Current on the New Bone Formation of Fractured Fibula in Rabbits)

  • 정형국;김진상;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제6권1호
    • /
    • pp.95-107
    • /
    • 1994
  • This study was performed to identify the effect of constant direct current and to give us methods which can be applied easily in clinic. Six rabbits was used at this experiment. After each animal was fractured at left fibula, divided into experimental group(n=3) and central group(n=3). Experiment duration of electrical stimulation on experimental rabbits was 35 days. Direct current from fifteen microampere to twenty microampere was passed continously through the placed electrode between fracture area and thigh. Negative electrode was placed at fracture area and positive at thigh. Roentgenography was used to observe bone-healing progression wet three times-at 15days, 25days and 35days after electrical stimulation. The results obtained are as followings: 1. Both experimental group and control group do not obtain callus formation on the first roentgenography(15 days after ES). 2. On the second roentgenography(25 days after ES), experimental group achieves above $70\%$ on fracture-healing, but control group achieves about $20-30\%$ on fracture healing. 3. On the third roentgenegraphy(35 nays after ES), experimental group achieves above $85-95\%$ on fracture healing and control group achieves about $60-70\%$ of bone union. Thus, statistically significance(independent t-test) was occured ie the second and third roentgenography between experimental group and control group.

  • PDF

여대생의 비만스트레스와 관련 요인에 관한 연구 (A Study on Obesity Stress and Related Factors among Female College Students)

  • 권영숙
    • 지역사회간호학회지
    • /
    • 제19권3호
    • /
    • pp.431-442
    • /
    • 2008
  • Purpose: The Purpose of this study was to examine the degree of obesity stress and analyze factors having an effect on obesity stress among college women. Method: The subjects were 347 female students from a university in J City. Data were collected using a self-report questionnaire for general characteristics, health-related characteristics, and current and preferred somatotype. Obesity stress was measured using 10 items developed by Cho (1996) based on Body Attitudes questionnaire (BAQ) of Ben-Tovim and Walker (1991). The survey was conducted from September 4 to September 7, 2007. Data were analyzed by t-test, ANOVA, Scheffe test, Spearman's rank correlation test, and stepwise multiple regression using SPSS 14.0. Results: The average score of obesity stress was $2.78{\pm}0.90$ out of 5.00. Stepwise multiple regression analysis showed that the major factors that affect obesity stress of female college students were perceived body shape, disagreement between current and preferred somatotype, history of weight control, body mass index (BMI), and perceived health status, and these factors explained 38.4% of obesity stress. Conclusion: Subjective judgment in the perception of or preference for body shape was the most important factor affecting obesity stress in female college students. Therefore, a plan is necessary to mitigate obesity stress and evaluate individually subjects who perceive themselves to be fat or want to be thinner than the current somatotype. And consultation and constant management are needed to help the high risk group (experience of weight control, BMI ${\geq}23kg/m^2$, not good health status).

  • PDF

Analysis on electrical and thermal characteristics of MI-SS racetrack coil under conduction cooling and external magnetic field

  • Chae, Yoon Seok;Kim, Ji Hyung;Quach, Huu Luong;Lee, Sung Hoon;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.61-69
    • /
    • 2021
  • This paper presents the analysis and experiment results on the electrical and thermal characteristics of metal insulation (MI) REBCO racetrack coil, which was wound with stainless steel (SS) tape between turn-to-turn layers, under rotating magnetic field and conduction cooling system. Although the field windings of superconducting rotating machine are designed to operate on a direct current, they may be subjected to external magnetic field due to the unsynchronized armature windings during electrical or mechanical load fluctuations. The field windings show the voltage and magnetic field fluctuations and the critical current reduction when they are exposed to an external magnetic field. Moreover, the cryogenic cooling conditions are also identified as the factors that affect the electrical and thermal characteristics of the HTS coil because the characteristic resistance changes according to the cryogenic cooling conditions. Therefore, it is necessary to investigate the effect of external magnetic field on the electrical and thermal characteristics of MI-SS racetrack coil for further development reliable HTS field windings of superconducting rotating machine. First, the major components of the experiment test (i.e., HTS racetrack coil construction, armature winding of 75 kW class induction motor, and conduction cooling system) were fabricated and assembled. Then, the MI racetrack coil was performed under liquid nitrogen bath and conduction cooling conditions to estimate the key parameters (i.e., critical current, time constant, and characteristic resistance) for the test coil in the steady state operation. Further, the test coil was charged to the target value under conduction cooling of 35 K then exposed to the rotating magnetic field, which was generated by three phrase armature windings of 75 kW class induction motor, to investigate the electrical and thermal characteristics during the transient state.

고강도콘크리트와 고강도철근을 사용한 교각의 내진거동 실험연구 (An Experimental Study on the Seismic Performance of RC Piers using High-strength Concrete and High-strength Rebars)

  • 오병환;박대균;조근호;신용석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.712-715
    • /
    • 2004
  • Five RC piers were tested under a constant axial load and a cyclically reversed horizontal load to investigate the behavior of RC piers used in the high-strength concrete and the high-strength rebars. Seismic design of piers were conducted under the same design, according to the current Korean Bridge Design Standard. The parameters of the test were concrete compressive strength and steel strength, steel ratio. The test results indicated that RC piers of the high-strength concrete and high-strength rebars exhibited ductile behavior and seismic performance.

  • PDF

Electrokinetic 정화 처리 중 토체내의 특성변화를 고려한 수치해석 프로그램 개발 (Development of Numerical Analysis Program Considering Variation of Soil Properties During Electrokinetic Remediation)

  • 한상재;김치열;김수삼
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.202-205
    • /
    • 2001
  • In this study, the electrokinetic remediation test for the kaolin contaminated by lead was performed and voltage, zeta potential, pH distribution, current, contamination transport in soil sample were studied and finite differential numerical analysis program(HERP) for a contaminated soil were compared with those of test. From the result of HERP, in the anode it was represented that the rest concentration was decreased with the voltage. Hence, if treatment time was continued for a long in the constant voltage, comparing with sample having no change in the rest concentration, it is considered that the voltage gradient is the control factor of the rest concentration.

  • PDF

마이크로 전해가공에서 임피던스의 영향 (The influence of impedance on micro electrochemical machining)

  • 강성일;주종길;박규열;전종업
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1893-1896
    • /
    • 2003
  • This research aimed to fabricate a micro structure using micro electrochemical machining (${\mu}$-ECM). with a view to that the theory of ${\mu}$-ECM is established accurately in a different way of conventional electrochemical machining. In details, if the impedance is existed in the system, it is difficult to analyze the micro electrochemical reaction efficiently in polarization curve using a potentiodynamic test. Hence, this research investigates the relationships between impedance and electric current measuring with a potentiostatic test applying to a pair or electrode as a constant potential. And this paper examines the influence of temperature of electrolyte on polarization curve for the quantitative analysis of electrochemical reactions.

  • PDF

Comparison of code provisions on lap splices

  • Canbay, Erdem
    • Structural Engineering and Mechanics
    • /
    • 제27권1호
    • /
    • pp.63-75
    • /
    • 2007
  • The code provisions on lap splices are critically assessed in the light of 203 beams without transverse reinforcement and 278 beams with transverse reinforcement. For comparison, the provisions given in the ACI 318, Eurocode 2, and TS 500 Codes are considered. The ACI Committee 408 recommended provision and a new proposal are also taken into account throughout the assessment. The comparison with real beam tests where the splice region was subjected to constant moment indicates that current provisions in the Codes do not agree acceptably with test results. The steel stress prediction graphs calculated by means of the Code provisions show high scatter and remain unsafe especially for test data without transverse reinforcement. Both the recent recommended provision by ACI Committee 408 and a new design expression proposed by the author have much less scatter with fewer unsafe predictions. The simplified design provision proposed by ACI Committee 408 does not yield similar results to that of the advanced design provision proposed by the same committee and therefore it could conveniently be replaced with the simpler equation proposed by the author.

LC 공진을 이용한 동기형 릴럭턴스 전동기의 파라미터 측정 (Parameter Measurement of Synchronous Reluctance Motor Using LC Resonance)

  • 김승주;안준선;김기찬;김솔;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1282-1284
    • /
    • 2005
  • As Synchronous Reluctance Motor gives reluctance torque, An inductance is an important parameter that is proportional to torque. To achieve the high performance in sensorless control, it is necessary to consider exact inductance values because the inductance is not a constant parameter anymore. Therefore, this paper shows the inductance measurement using DC current decay test and Generator-Resonance test.

  • PDF

전기이중층커패시터의 가속열화시험 (An Accelerated Degradation Test of Electric Double-Layer Capacitors)

  • 정재한;김명수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권2호
    • /
    • pp.67-78
    • /
    • 2012
  • An electric double-layer capacitor(EDLC) is an electrochemical capacitor with relatively high energy density, typically hundreds of times greater than conventional electrolytic capacitors. EDLCs are widely used for energy storage rather than as general-purpose circuit components. They have a variety of commercial applications, notably in energy smoothing and momentary-load devices, and energy-storage and kinetic energy recovery system devices used in vehicles, etc. This paper presents an accelerated degradation test of an EDLC with rated voltage 2.7V, capacitance 100F, and usage temperature $-40^{\circ}C{\sim}65^{\circ}C$. The EDLCs are tested at $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$, respectively for 1,750hours, and their capacitances are measured at predetermined times by constant current discharge method. The failure times are predicted from their capacitance deterioration patterns, where the failure is defined as 30% capacitance decrease from the initial one. It is assumed that the lifetime distribution of EDLC follows Weibull and Arrhenius life-stress relationship holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

점탄성 특성을 가진 폴리머용액의 난류유동 열적입구길이에 관한 실험적 연구 (An experimental study on the thermal entrance lengths for viscoelastic polymer solutions in turbulent tube flow)

  • 유상신;황태성;엄정섭
    • 대한기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.1189-1196
    • /
    • 1988
  • 본 연구에서는 내경이 각각 8.5mm와 10.3mm이며 무차원길이가 각각 710과 1158인 두 개의 시험관을 사용하는 유동장치를 제작하여 시험관 입구에서부터 유체역 학적 경계층(hydrodynamic boundary layer)과 열적 경계층(thermal boundary layer)이 동시에 발달하기 시작하는 경계조건을 형성하고 관벽에서 일정한 열 플럭스(constant heat flux)를 발생하는 조건을 부여하였다. 퇴화현상(degradation)에 대하여 비교적 안정성을 가진 폴리아크라마이드(polyacrylamide) Separan Ap273을 수도물에 용해하여 제조한 폴리머용액으로 유동특성과 열전달특성을 실험하여 열적입구길이와 열전달특성 을 규명하고자 한다.