• Title/Summary/Keyword: Constant current source

Search Result 250, Processing Time 0.038 seconds

Development of Deterioration Diagnosis System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화진단시스템 개발)

  • 김성덕;이승호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.43-50
    • /
    • 2000
  • Design and experiments of a nondestructive testing system with a solenoid eddy current sensor to inspect deterioration of ASCR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wires) usually used in HV overhead distribution lines in domestic areas in presented in this paper. Through corrosion mechanisms and deterioration results for ACSR-OC conductors are examined, it is shown that corrosion may lead to the reduction of the effective cross section area of conductors is proposed. The measurement system consisting of a constant current source with a RF frequency, a signal processing unit and a motor driver/ controller is designed and implemented. This instrument has such capabilities as detecting the sensor output and estimating diameter change of the testing conductors, continuously. As a result, it was verified that such corrosion detector system with an eddy current sensor can be shown good effectiveness for estimating the serious faults due to deterioration in overhead distribution lines and giving an early warming before severe aged conductor may lead to fail.

  • PDF

Design and Fabrication of an Electronic Ballast for Short-Arc Lamps (Short-Arc 램프용 전자식 안정기의 설계 및 제작)

  • Kim Il-Kwon;Han Ju-Seop;Kil Gyung-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.4
    • /
    • pp.652-658
    • /
    • 2006
  • This paper deals with an electronic ballast for hish intensity short-arc discharge lamps, which consists of a boost converter, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit The ignition circuit generates high voltage pulses of 130[Hz] up to 5 [kV]. A reignition circuit is equipped in the ballast, and it operates the lamp at a regular interval for protection when an ignition fails. Acoustic resonance phenomenon was eliminated by operating a low frequency square wave voltage and current. The measured lamp voltage, current and consumption power were 123.8 [V], 8.1 [A] and 1,002 [W], respectively. From the experiment, we confirmed that the prototype ballast operates the lamp with a constant power.

Al$_2$O$_3$ formation on Si by catalytic chemical vapour deposition

  • Ogita, Yoh-Ichiro;Shinshi Iehara;Toshiyuki Tomita
    • Electrical & Electronic Materials
    • /
    • v.16 no.9
    • /
    • pp.63.1-63
    • /
    • 2003
  • Catalytic chemical vapor deposition (Cat-CVD) has been developed to deposit alumina(Al$_2$O$_3$) thin films on silicon (Si) crystal using N$_2$ bubbled tir-methyl aluminium [Al(CH$_3$)$_3$, TMA] and molecular oxygen (O$_2$) as source species and tungsten wires as a catalyzer. The catalyzer dissociated TMA at approximately 600$^{\circ}C$ The maximum deposition rate was 18 nm/min at a catalyzer temperature of 1000 and substrate temperature of 800$^{\circ}C$. Metal oxide semiconductor (MOS) diodes were fabricated using gates composed of 32.5-nm-thick alumina film deposited as a substrate temperature of 400oC. The capacitance measurements resulted in a relatively dielectric constant of 7, 4, fixed charge density of 1.74*10e12/$\textrm{cm}^2$, small hysteresis voltage of 0.12V, and very few interface trapping charge. The leakage current was 5.01*10e-7 A/$\textrm{cm}^2$ at a gate bias of 1V.

  • PDF

Innovative Electromagnetic Induction Eddy Current-based Far Infrared Rays Radiant Heater using Soft Switching PWM Inverter with Duty Cycle Control Scheme

  • Tanaka H.;Sadakata H.;Muraoka H.;Okuno A.;Hiraki E.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.64-68
    • /
    • 2001
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction heated type far infrared rays radiant heating appliance using the voltage-fed edge-resonant ZVS-PWM high frequency inverter using IGBTs for food cooking and processing which operates under a constant frequency variable power regulation scheme. This power electronic appliance with soft switching high frequency inverter using IGBTs has attracted special interest from some advantageous viewpoints of safety, cleanliness, compactness and rapid temperature response, which is more suitable for consumer power electronics applications.

  • PDF

Line-Interactive DVR Using Multi-Level H-Bridge Inverter (멀티-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR)

  • Kang Dae-Wook;Woo Sung-Min;Kim Tae-Jin;Choi Chang-Ho;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.139-143
    • /
    • 2001
  • Recently, the interest on power quality has been hot issue. The equipments cause voltage disturbance and has become more sensitive to the voltage disturbance. This paper deals with 5-Level H-Bridge Line-Inter active Dynamic Voltage Restorer(LIDVR) system. The LIDVR has following advantages in comparison with the DVR with series injection transformer It has the power factor near to unity under normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then a voltage controller is proposed to get sinusoidal load voltage with constant amplitude. To find PWM method suitable for H-Bridge converter, two PWM methods are compared and analyzed. Finally, simulation results verify the proposed 5-level H-Bridge LIDVR system.

  • PDF

H-type Structural Boost Three-Level DC-DC Converter with Wide Voltage-Gain Range for Fuel Cell Applications

  • Bi, Huakun;Wang, Ping;Che, Yanbo
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1303-1314
    • /
    • 2018
  • To match the dynamic lower voltage of a fuel cell stack and the required constant higher voltage (400V) of a DC bus, an H-type structural Boost three-level DC-DC converter with a wide voltage-gain range (HS-BTL) is presented in this paper. When compared with the traditional flying-capacitor Boost three-level DC-DC converter, the proposed converter can obtain a higher voltage-gain and does not require a complicate control for the flying-capacitor voltage balance. Moreover, the proposed converter, which can draw a continuous and low-rippled current from an input source, has the advantages of a wide voltage-gain range and low voltage stress for power semiconductors. The operating principle, parameters design and a comparison with other converters are presented and analyzed. Experimental results are also given to verify the aforementioned characteristics and theoretical analysis. The proposed converter is suitable for application of fuel cell systems.

Multi-Frequency Electrical Impedance Tomography System (다주파수 임피던스 단층촬영 시스템)

  • Oh, Tong-In;Cho, Seong-Phil;Kim, Sang-Min;Koo, Hwan;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.66-74
    • /
    • 2007
  • We have developed a multi-channel, multi-frequency EIT system with operating frequency of 10Hz to 500KHz. The number of digital voltmeters using phase-sensitive demodulation can be varied from 8 to 64 and we found that 16 and 32-channels are most practical. This paper describes the design, implementation, and construction of 16 and 32-channel systems. The performance of the system was thoroughly tested and we found that CMRR of the developed voltmeter is about 85dB with $100{\Omega}$ unbalancing series resistor. The SNR is greater than 99.6dB and the output impedance of the constant current source is $1{\Omega}W$ at least for all frequencies. Imaging experiments using a banana with frequency-dependent conductivity and permittivity show that frequency-difference imaging is possible using the developed system. Future works of animal and human experiments are discussed.

A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter (7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어)

  • Kang, Dae-Wook;Hyun, Dong-Seok;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

Radiation characteristics of A Circular Loop antenna In Moving Media (운동매질내에서의 Circular Loop Antenna의 개체특성)

  • 최병하
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.3
    • /
    • pp.12-18
    • /
    • 1970
  • In this paper, the radiation characteristics of a Circular Loop Antenna is studied in a moving homogeneous, isotropic and linear media with a constant velocity much less than the speed of light. In Stuffing the radiation characteristics, Srst vector potential on the loop antenna is derived in the moving media by appling Maxwell-Minkowaski's theory. Next, using the derived relations, the electric and magnetic Seld is calculated for the spec-i Sed wave length ana velocity of the media. The Seld patterns in the moving media are compared with those of stationary media. We find that the intensity of the field is reduced in the direction of the media velocity and increased in the opposite direction only for the component parallel with the plane of the antenna. The deviation from the stationary media is proportional to the velocity of the media and the frequency of source current.

  • PDF

Elderly Group Homes in Korea - How They are Operated and What Needs to Be Done to Promote Them? - (노인공동생활가정의 운영 실태 및 활성화 방안)

  • Jee, Eun-Young
    • Journal of the Korean housing association
    • /
    • v.26 no.5
    • /
    • pp.53-60
    • /
    • 2015
  • This study is aimed at identifying and evaluating the current operating model of elderly group homes in Korea, which were introduced with the amendment to the Welfare of the Aged Act in 2008, based on a survey of 25 managers of such homes. There are several key themes identified in the evaluation of their operation in terms of human resources, service, space and finance. The number of employees at the homes complied with the applicable law, with the majority having more employees than the minimum legal requirement for the care of residents. A wide variety of service programs were offered for residents. Typically located within detached houses purchased on the first floor, the homes varied in size from 73 square meters to 560 square meters, with each having a distinctly residence-like atmosphere. The greatest challenge such homes face was a shortage of financial resources. Many struggled to operate because they have no other source of revenue than payments from residents. Consequently, to help promote elderly group homes, there needs to be state-level support for the view that providing assistance for self-sufficient elders can save social costs in the long run by delaying their transition to a physical state requiring constant nursing.