• Title/Summary/Keyword: Constant current source

Search Result 250, Processing Time 0.048 seconds

An electric pulp tester using a constant current source (정 전류원 이용한 치수(齒髓) 검사기)

  • Kim, J.S.;Nam, K.C.;Kim, S.C.;Lee, S.J.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.720-723
    • /
    • 2003
  • Electric stimulation of teeth is used for assessing pulp vitality. Because of very high and wide range of impedance of the enamel, electric pulp testers use high voltage, high output impedance and alternative current source. Most pulp testers use voltage stimulation method and their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation in enamel thickness. In this study, we constructed a constant current source type of pulp tester with the maximum current of 150 uA.

  • PDF

Alternating Current (AC) Powered LED Lighting Technology with Constant Brightness (빛의 밝기가 일정한 교류 구동 LED 조명기술)

  • Lee, Dong Won;Ahn, Ho-Myoung;Kim, Byungcheul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.466-470
    • /
    • 2022
  • In order to widely disseminate LED lighting, LED lighting technology that directly uses AC commercial power has been recently introduced. AC powered LED lighting technology has a problem in that the light brightness of the LED changes because the voltage applied to the LED and the current flowing through the LED continuously change. In this study, when the LED current is greater than the design current, the current control signal generated by the controller is supplied to the current source to supply only the design current to the LED by increasing the voltage drop at the current source. If it is smaller than the design current, the controller is adjusted so that the current is supplied only to the LED without a voltage drop in the current source. It can be seen that the higher the maximum rectified voltage, the faster the lighting time of the LED light emitting block is, so that the power factor of the LED lighting is improved. The LED lighting technology proposed in this study enables LED lighting with constant light brightness, reduced power consumption, and long lifetime.

The Improvement of Accuracy and Measurement Speed in the Low Current Measurement System (저전류 측정 시스템에서의 정밀도 및 측정 속도 향상)

  • Baek, Wang-Ki;Choi, In-Kyu;Park, Jong-Sik;Lee, Kyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.550-553
    • /
    • 2002
  • A source meter is a basic instrument to perform a measurement of DC characteristic of semiconductor devices. the source meter can be used as variable voltage source, variable current source, voltage meter, or current meter. The accuracy of the low current measurement can be improved with the compensation of leakage current and charge and discharge current. In the low current measurement, the RC time constant is extremely big, so the measurement speed is very low. In this thesis, the analysis of the behavior of the measurement current according to the RC time constant and output capacitance and the method to accelerate the measurement speed.

  • PDF

Current Controlled PWM for Multilevel Voltage-Source Inverters with Variable and Constant Switching Frequency Regulation Techniques: A Review

  • Gawande, S.P.;Ramteke, M.R.
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.302-314
    • /
    • 2014
  • Due to advancements in power electronics and inverter topologies, the current controlled multilevel voltage-source pulse width modulated (PWM) inverter is usually preferred for accurate control, quick response and high dynamic performance. A multilevel topology approach is found to be best suited for overcoming many problems arising from the use of high power converters. This paper presents a comprehensive review and comparative study of several current control (CC) techniques for multilevel inverters with a special emphasis on various approaches of the hysteresis current controller. Since the hysteresis CC technique poses a problem of variable switching frequency, a ramp-comparator controller and a predictive controller to attain constant switching frequency are described along with its quantitative comparison. Furthermore, various methods have been reviewed to achieve hysteresis current control PWM with constant switching frequency operation. This paper complies various guidelines to choose a particular method suitable for application at a given power level, switching frequency and dynamic response.

Simultaneous Measurements of Drain-to-Source Current and Carrier Injection Properties of Organic Thin-Film Transistors

  • Majima, Yutaka
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.271-272
    • /
    • 2007
  • Displacement current $(I_{dis})$ and drain-to-source current $(I_{DS})$ are evaluated using the simultaneous measurements of source $(I_S)$ and drain $(I_D)$ currents during the application of a constant drain voltage and a triangular-wave gate voltage $(V_{GS})$ to top-contact pentacene thin-film transistors.

  • PDF

The Control of load Commutated Current Source Inverter for Induction Motor Drive (유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御))

  • Chung, Y.T.;Sim, J.M.;Lee, S.Y.;Soh, Y.C.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF

Compensation of the rotor time constant of induction motor using current error feedback (전류오차 궤환을 이용한 유도전동기 회전자 시정수 보상)

  • 김승민;이무영;권우현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.195-198
    • /
    • 1997
  • This paper proposes the effective compensation method of the rotor time constant of induction motor. An indirect vector control method is highly dependent on the motor parameters. To solve the problem of performance degradation due to parameter variation in an indirect vector control of induction motor, we compensate the rotor time constant by current error feedback. The proposed method is a simple on-line rotor time constant compensation method using the information from terminal voltages and currents. As the current error, difference between current command and estimated current, approaches to zero, the value of rotor time constant in an indirect vector controller follows the real value of induction motor. This scheme is valid transient region as well as steady state region regardless of low or high speed. This method is verified by computer simulation. For this, we constructed the simulation model of induction motor, indirect vector controller and current regulated PWM (CRPWM) voltage source inverter (VSI) using SIMULINK in MATLAB.

  • PDF

Commutation Performance of Current Source Converters fed Switched Reluctance Motors (스위치드 리럭턴스 전동기 구동 전류형 컨버터의 전류특성)

  • Jang, Do-Hyun;Choe, ㅍ;Kim, Ki-Su;Jeong, Seon-Ung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.38-46
    • /
    • 1996
  • The commutation operation of the current source converter for switched reluctance motor drives is analyzed in this paper. The commutation operation in the current source converter consists of two modes. At turn-off of phase switch, the phase current decreases sinusoidally, and the sum of two phase currents during commutation period is constant. At this time, the capacitor voltage increases quickly with changing polarity and decreases slowly when another phase switches turn on or off. Frequency of step-down DC chopper in the current source converter is low because of the dump such as BJTs and GTOs are possible as phase switches instead of Power MOSFET and IGBTS. They may result in reductions of conduction losses and manufacturing cost in the current source converter comparing to the voltage source converter of SRM.

  • PDF

Characteristic of Hydrogen-oxygen Mixed Gas Power Conversion System (혼합수소발생기용 전력변환장치의 특성)

  • Mun, Sang-Pil;Lee, Hae-Su;Nakaoka, Mutsuo;Jeong, Jang-Geun;Kim, Chang-Il;Jo, Gil-Je;Kim, Sang-Don
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.323-326
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using SCR converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input rower, it has acquired higher input power per Gas quantities at put pulse current. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

A study on high speed control of step motor using current source (전류원을 이용한 스텝 모타의 고속 제어에 관한 연구)

  • 오동성;김종준;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.594-596
    • /
    • 1987
  • In this study, a method of obtaining reasonably large and constant torque at high speed is given in order to improve the performance of the open loop controlled step motor system using the current source, thus resulting in high performance compared to the conventional current limiting using resistor and chopper.

  • PDF