• Title/Summary/Keyword: Connection member

Search Result 257, Processing Time 0.026 seconds

An Experimental Study on Connection System of FRP Modular Box Member (FRP 모듈형 박스 부재의 연결 시스템에 관한 실험적 연구)

  • Kwak, Kae-Hwan;Jang, Hwa-Sup;Yang, Dong-Woon;Kim, Ho-Sun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.4
    • /
    • pp.29-36
    • /
    • 2009
  • This is a basic experimental study to apply FRP modular box member to a variety of construction structures exposed to flexural strength, such as a slab and a girder. Applying FRP modular box member to a real structure requires a large section. FRP box member was made into modular systems. Tests were conducted under various conditions in order to analyze jointing performance of the developed FRP modular box member as a large section. For the methods of jointing FRP modular box member, synthetic resins connection, mechanical connection, and a combination of both were used to test both length and breadth connection. As a result of the test, using urethane + two bolts + sheets was the most efficient method of connecting FRP modular box member. It is expected that the proposed joint system in this study will contribute to the increase of failure load and synthesis behavior of FRP modular box member.

A Comparative Study on Design by Actual Stress and Design by Member Strength in Bolt Connections (철골볼트 접합부 존재응력설계와 부재내력설계의 비교 연구)

  • 이만승
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.94-101
    • /
    • 1999
  • There are two methods commonly used in design of splice plate connection of frame structure. The one is Design by Actual Stress which can sufficiently transfer actual force to an adjacent member using rows of bolts. The other is Design by Member Strength which is able to transfer total allowable stress of effective section area to a connected member. In real design, as a matter of convenience, Standard Connection Drawings have used according to Design by Member Strength. But this method underestimate connection force in shear connection where large connection moment occured. In this study, these Design methods are compared by connection moment in shear connections. and the adequate use of them are recommended. Also In order to evaluate more accurately the actual stress of splice plate of flange on moment. connection, a new calculation method of it is recommended.

  • PDF

Connection Behavior of FRP Box Member of Connection Method (연결방법에 따른 FRP 박스 부재의 연결거동 특성)

  • Jang, Hwa-Sup;Kim, Ho-Sun;Kwak, Kae-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.455-463
    • /
    • 2010
  • This is a basic experimental study to apply FRP modular box member to a variety of construction structures exposed to flexural strength, such as a slab and a girder. Tests were conducted under various conditions in order to analyze jointing performance features of the developed FRP modular box member as a large section. For the methods of jointing FRP modular box member, chemical connection, mechanical connection, and a combination of both were used to test both vertical and horizontal jointing. As a result of the test, using urethane+two bolts+sheets was the most efficient method of connecting FRP modular box member, and confirmed the efficient behavior by a finite element analysis.

The Study on Compressive Behavior of Connection Member between Steel Pipe Pile and Concrete Footing (강관말뚝 기초 두부 연결부의 압축거동에 관한 연구)

  • Youn, IL-Ro;Hong, Ki-Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.3
    • /
    • pp.183-190
    • /
    • 2006
  • Generally, application of steel pile as deep foundation member needs specials requirement for the connection method between steel pipe and concrete footing. To investigate real compressive behavior of connection member between steel pipe pile and concrete footing, three specimens were tested with carefully designed experimental system. Main test variable is the connection method between steel pipe pile and concrete footing. The bolted bonding method and hook bonding method was considered as the connection method in this study. From the test results gained from experiment, it was conformed that two types of connection method have the almost same compressive resistance capacity. Therefore, we can conclude that these two connection methods can be used as the strengthening method to verify the compressive composite action of concrete and steel pipe pile.

  • PDF

The Elasto-Plastic Buckling Analysis of Ball-jointed Sing1e Layer Latticed Domes Considering the Connection Characteristics (접합부의 성질을 고려한 볼 접합 단층 래티스 돔의 탄소성 좌굴해석)

  • 한상을;권현재;신용환;배상달;이진섭
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.90-100
    • /
    • 2000
  • The present paper investigates the elasto-plastic buckling of ball-jointed single layer latticed domes considering the connection characteristics. The domes are composed of tubular member elements, ball joints and connectors. To judge yielding of the member, the ends and central part of tubular member elements are assumed as five elasto-plastic springs. Elasto-plastic buckling load can be identified the yielding load of estimated member As a numerical analysis technique, loading incremental method based on the Newton-Raphson method is used. The effects of connection characteristics are investigated by the following points; (1) the length of rigid zone, (2) looseness of screw, (3) diameter of connector Finally, it is emphasized that the connection characteristics as well as the material non-linearity have significant effects upon the buckling toad of domes.

  • PDF

Tensile Strength on Connection Socket of Cables (케이블 연결 소켓의 인장강도)

  • Park, Kang-Geun;Lee, Jang-Bok;Ha, Chae-Won;Kim, Jae-Bong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.37-42
    • /
    • 2008
  • Cable member in structure is tension systems in which the load carrying members transmit loads to support system by tensile stress with no compression or flexure allowed. Cable system have been widely used large span structure roof, air-supported structure, prestressed membrane, cable network roof, suspension structures, guyed tower, ocean platforms, suspension bridges. Cable member can transmit loads by the edge connected system such as socket, swaging, mechanical splice sleave, clip, wedge, loop splice etc. This study will shown an experimental results on the strength of connection socket of cables. In the results of experiment, most of cable connection specimen occurred the failure at the connection socket part before the cable arrived at tensile failure load.

  • PDF

The elastic bucking strength of axially compressed tubular member with through-gusset connection (관통한 가셋트판이 부착된 압축 강관 부재의 탄성좌굴내력)

  • Kim, Woo-Bum;Lim, Ji-Youn
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.133-141
    • /
    • 2001
  • A tubular member holding an axially through-gusset connection is often used to transmit axial compression in a steel truss structures. The elastic buckling loads of the member is affected by the stiffness ratio($\beta$) and the length ratio(G) because of two elements with different properties. In current code, however, the strength is evaluated with an effective length factor k=0.9 without considering the above effect. Therefore this study analyzed a theoretical mechanism based on the elasticity theory and performed a finite element analysis to investigate the influence parameters on the elastic buckling strength of axially loaded member.

  • PDF

Reliability Analysis of Three-Dimensional Temporary Shoring Structures Considering Bracing Member and Member Connection Condition (가새재 및 부재 연결 조건을 고려한 3차원 가설 동바리 구조물의 신뢰성 해석)

  • Ryu, Seon-Ho;Ok, Seung-Yong;Kim, Seung-Min
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • This study performs reliability analysis of three-dimensional temporary shoring structures with three different models. The first model represents a field model which does not have diagonal bracing members. The installation of bracing members is often neglected in the field for convenience. The second model corresponds to a design model which has the bracing members with the hinge connection of horizontal and bracing members at joints. The third model is similar to the second model but the hinge connection is replaced with partial rotational stiffness. The reliability analysis results revealed that the vertical members of the three models are safe enough in terms of axial force, but the vertical and horizontal members exhibit a big difference among the three models in terms of combination stress of axial force and bi-axial bending moments. The field model showed significant increase in failure probability for the horizontal member, and thus the results demonstrate that the bracing member should be installed necessarily for the safety of the temporary shoring structures.

A Lossless Multicast Handoff Method for Wireless ATM Networks (무선 ATM 망을 위한 손실없는 멀티캐스트 핸드오프 기법)

  • 하은용
    • The KIPS Transactions:PartC
    • /
    • v.8C no.1
    • /
    • pp.88-96
    • /
    • 2001
  • Future mobile communication networks, which consist of ATM-based B-ISDN backbone networks and wireless ATM networks, will provide u user with broadband connection and QoS service. These network systems need the lossless handoff methods which support user mobility, satisfy ATM features such as ATM cell ordering and no ATM cell duplication and minimize buffer requirement for ATM cell buffering. In this paper we suggest a multicast-based handoff method to supp$\alpha$t lossless connection as well as to minimize buffer overhead. It establishes a dynamic multicast connection between source terminal and wireless member AP (access point)s. When the mobile terminal receives data packet correctly, it notifies the positive acknowledgement of the packet to all member APs. And member APs then release the MT related temporary buffer space for MT's future movement. Therefore member APs can eliminate unnecessary buffer usage and manage the buffer space efficiently. Analysis result shows that our handoff method has better performance in buffer requirement for lossless and seamless connection services over VCT (virtual connection tree) method and other dynamic multicast-based handoff methods.

  • PDF

Seismic Response Enhancement through Stiffness Connection of Two Adjacent Buildings equipped with ATMD (ATMD가 설치된 두 인접빌딩간 강성연결방식을 통한 내진성능 개선)

  • Park, Kwan-Soon;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.47-53
    • /
    • 2017
  • In this study, we propose a new control system that effectively utilizes the interaction effect of control force through the connection of stiffness member for seismic performance enhancement of two adjacent structures equipped with active tuned mass damper (ATMD). The efficiency of the proposed control system is verified by comparing with the existing independent control system through the numerical simulations of the 10th- and 12th-story buildings. From the numerical results, it is confirmed that the proposed method can show similar or better control performance even with more economical control capacity than the existing independent control system. Another advantage is that the existing system does not exhibit the adaptive control performance in emergency of failure of one control device, whereas the proposed system can achieve successful adaptive control performance by economically and efficiently utilizing the interacting control effect through the connection member.