• Title/Summary/Keyword: Connected-ring

Search Result 156, Processing Time 0.026 seconds

THE DIMENSION GRAPH FOR MODULES OVER COMMUTATIVE RINGS

  • Shiroyeh Payrovi
    • Communications of the Korean Mathematical Society
    • /
    • v.38 no.3
    • /
    • pp.733-740
    • /
    • 2023
  • Let R be a commutative ring and M be an R-module. The dimension graph of M, denoted by DG(M), is a simple undirected graph whose vertex set is Z(M) ⧵ Ann(M) and two distinct vertices x and y are adjacent if and only if dim M/(x, y)M = min{dim M/xM, dim M/yM}. It is shown that DG(M) is a disconnected graph if and only if (i) Ass(M) = {𝖕, 𝖖}, Z(M) = 𝖕 ∪ 𝖖 and Ann(M) = 𝖕 ∩ 𝖖. (ii) dim M = dim R/𝖕 = dim R/𝖖. (iii) dim M/xM = dim M for all x ∈ Z(M) ⧵ Ann(M). Furthermore, it is shown that diam(DG(M)) ≤ 2 and gr(DG(M)) = 3, whenever M is Noetherian with |Z(M) ⧵ Ann(M)| ≥ 3 and DG(M) is a connected graph.

Study on Effect of Anchor Bolt by Thermal Expansion of Sulfur Storage Tank under High Temperature (고온을 받는 유황저장탱크의 열팽창에 의한 앵커볼트 영향에 관한 연구)

  • Jung, Wook-Hwan;Kim, Jeong-Soo;Kim, Tae-Min;Kim, Moon-Kyum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.483-490
    • /
    • 2016
  • In plant industry, sulfur storage tank is made of steel and annular plate is connected with concrete foundation of ring wall type by anchor bolt. Due to keep sulfur at high temperature in tank by coil, sulfur storage tank is expanded larger than another tank stores fluid at room temperature. Generally, structural design of tank foundation is performed analysis with loading of temperature gradient between inner and outer surface, this method can't consider the phenomenon that load is intensively transferred to concrete foundation at anchor bolt. This means that temperature load is underestimated and causes crack of concrete near anchor bolt. In this study, evaluation formula considering temperature load transfer mechanism through anchor bolt is proposed and load acting on concrete foundation is rationally decided. For this purpose, it is analyzed variation of thermal load per various anchor bolt number using finite element model including tank annular plate and anchor bolt. Solution is proposed as specified term combining result of analysis and theoretical solution for evaluating load transferred by anchor bolt. For confirmation of validation of proposed formula, it is applied in design of sulfur storage tank at plant site, it shows that the formula can be practically applied.

Structural Characteristics of Vascular Tissue in Carrot Seedlings with Anomalous Cotyledon Developed from Somatic Embryos (당근의 체세포배로부터 발생한 이상자엽 유식물의 유관속 조직의 구조적 특성)

  • 홍성식;소웅영
    • Korean Journal of Plant Tissue Culture
    • /
    • v.25 no.1
    • /
    • pp.69-74
    • /
    • 1998
  • The somatic embryos of Daucus carota L. cv. Hongshim developed in MS basal medium far 4 weeks had varied number of cotyledons. Palisade and spongy parenchyma of cotyledon were not clearly discriminated in all seedlings developed from the embryos. No independent existence of collateral vascular bundle was observed in all seedlings with various types of cotyledon ; instead, vascular bundles were either interconnected or partially connected with one another. Most of the cotyledonary bases on hypocotyl showed short cylinder structure which encircle plumule. The vascular tissues of cotyledonary bases and nodes of seedlings with jar-shaped or 1 cotyledon were connected in ring forms, showing the pattern of ectophloic shiphonostele, and similar ring form structure was also found in the vascular arrangement of 5 cotyledon seedlings. The vascular bundles of seedlings with 2, 3 and 4 cotyledons in many cases had independently arranged within the cotyledonary bases and nodes, showing the pattern of eustele. In hypocotyl, tetrarch or hexarch xylems prevailed in seedlings with jar-shaped cotyledon or 1 and 5 cotyledon; tetrarch xylems prevailed in 2 cotyledon seedlings; and triarch xylems prevailed in 3 cotyledon seedlings. In most of seedlings, cortex vascular bundles were dispensed in the region from cotyledonary node to hypocotyl, but double vascular bundles were also observed occasionally. In roots, diarch xylems were observed in most of seedlings with 2 cotyledons, triarch xylems in half of seedlings with 3 cotyledons, and diarch xylems in most of the remaining seedlings with the occasional occurrences of tetrarch xylems.

  • PDF

Changes of Vascular Contraction and Relaxation of Rat aorta under Arsenic Stress (비소 스트레스에 의한 흰쥐 대동맥의 수축과 이완반응의 변화양상)

  • 권윤정;박태규;성유진;김인겸;김중영
    • Journal of Life Science
    • /
    • v.13 no.5
    • /
    • pp.634-641
    • /
    • 2003
  • In order to examine whether arsenic, one of environmental stress, contribute to augumentation and relaxation of rat aorta, this study was performed in vivo and in vitro, using intacted or denuded rats aorta ring preparation, respectively. The carotid arterial pressure was recorded on an ink-writing physiograph(Grass Co. 79E) connected to strain gauge. The contractile response of vascular ring with or without endothelium preparation isolated from rat were determined in organ bath and was recorded on physiograph connected to isometric transducer. Vasopressin-,and phenylephrine- induced increase in arterial pressure significantly enhanced in arsenic-treated rats; increase of 19.1%, and 46.6%, respectively. Vascular contractile response was measured in vitro preparations exposed to 0, 0.5, 1, 2 and 4 mM of arsenic for 1, 3, 5 and 8 hours. The dose-vascular responses of phenylephrine augmented by increasing dose of arsenic in the strips exposed to arsenic for 8 hours, and did not augmented for 1, 3, 5 hours. The phenomenon was not affected by strips denuded endothelium. And the response of relaxation of rat aorta induced by nitroprusside was not influenced by arsenic stress, but acetylcholine was a little increased. compared to that of control. There were no significant difference in relaxation between control and arsenic treated rings with endothelium or denuded. All of the results, phenyleprine-induced vascular contraction was significantly enhanced in 4 mM arsenic-treated rat aortic rings compared with control, whether endothelium was present or denuded at 8 hours after arsenic treatment. It may be a mechanism by which long-term arsenic stresses play a role in development of hypertension.

Study for Fire Examples of LPG Leakage Including Fuel hose, Injector and Pressure Regulator Connector in Vehicle (자동차 연료호스, 인젝터 및 압력조절기 연결부에서 LP 가스 누출에 의한 화재사례 고찰)

  • Lee, Il Kwon;Kook, Chang Hoo;Suh, Moon Won;Jung, Dong Hwa
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • The purpose of this paper is to study for fire example by fuel leakage in LPG Vehicle. At first example, the car was repaired the fuel line that was connected with pressure hose between fuel regulator and injector in engine. But the service man was not very tighten with regular torque. At a result, the gas leaked on hot parts of engine. It verified the production of fire by engine heat. At second example, when the repair man, after replacement the injector, inserted the injector in a assembling part of it, he didn't the transform condition of fixing part. Therefore, the tearing phenomenon of O ring producted the controlled leakage of fuel by the injector deflection. It found the fact that the fuel leaked with gap of O ring. At third example. the fuel-cut solenoid valve was lined with pressure regulator unit. But the service man didn't throughly certify the leaked work of connected parts after repaired it. As a result, it certified the fire by engine heating leaked liquefied petroleum gas. Therefore it have to minimize the fire production that the driver should do no problem to throughly manage the fuel system.

Research on changes of spatial configuration due to complexation of public library (공공도서관의 복합화에 따른 공간의 구조적 변화에 관한 연구)

  • Song, Seung-Eon;Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.311-320
    • /
    • 2011
  • Public libraries in Korea have undergone changes from libraries for just reading or keeping books to libraries with cultural facilities that provide information through various media. It was because of the "plan for building the information-oriented library" in 2000 that made the complexation of public library in progress. The alterations of the system have changed the structure as well as the grade ranks but haven't been considered enough for administrators or visitors. Hereupon, we are to study of the features by analyzing how the application of the system changed the structure of library. There are four stages in research methods. First, concept of public library and functional elements requested in the process of complexation were studied from literature. Second, vertical, horizontal and circulate changes were studied by applying subject libraries into prior research stereotyping the libraries. Third, mutual relations between each place were studied through J-Graph by elements. Lastly, rank changes according to centrality of space and users were quantitatively studied with space syntax. 4 notable changes were found in these analyses. (1)Vertical, horizontal and circulate structure of public libraries were homogenized. Since 2001, however, they have become diversified as all-in-one or detachable. (2)The space structure of library before 2001 was shallow tree shape while in 2001, period of transition, was the tree shape mixed with ring shape. As time goes on, it has become shallow tree shape again but connected by ring shape in part of reading and common space and in digital reference room. (3)Digital reference room was center of the space around 2001 and it ranked top for integration. After 2007, however, it has become setting off-center. (4)About the purpose of using public libraries, using it as space for administrators ranked top followed by space for visitors and common space before. For now, common space ranks top and space for visitors and administrators. 5 subject public libraries were selected respectively before and after 2001.

Development of 2W-Level Wireless Powered Energy Harvesting Receiver using 60Hz power line in Electricity Cable Tunnel (전력구 내 지중선을 이용한 2W급 상용주파수 무선전력 수신장치 개발)

  • Jang, Gi-Chan;Choi, Bo-Hwan;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.296-301
    • /
    • 2016
  • Using high magnetic flux from a 60 Hz high-current cable, a 2 W wireless-powered energy harvesting receiver for sensor operation, internet of things (IoT) devices, and LED lights inside electrical cable tunnels is proposed. The proposed receiver comprises a copper coil with a high number of turns, a ring-shaped ferromagnetic core, a capacitor for compensating for the impedance of the coil in series, and a rectifier with various types of loads, such as sensors, IoT devices, and LEDs. To achieve safe and easy installation around the power cable, the proposed ring-shaped receiver is designed to easily open or close using a clothespin-shaped handle, which is made of highly-insulated plastic. Laminated silicon steel plates are assembled and used as the core because of their mechanical robustness and high saturation flux density characteristic, in which the thickness of each isolated plate is 0.3 mm. The series-connected resonant capacitor, which is appropriate for low-voltage applications, is used together with the proposed receiver coil. The concept of the figure of merit, which is the product weight and cost of both the silicon steel plate and the copper wire, is used for an optimized design; therefore, the weight of the fabricated receiver and the price of raw material is 750 gf and USD $2 each, respectively. The 2.2 W powering capability of the fabricated receiver was experimentally verified with a power cable current of $100A_{rms}$ at 60Hz.

Implementation of Ring Buffer based Massive VLBI Data Stream Input/Output over the Wide Area Network (광역 네트워크 상의 링 버퍼 기반 대용량 VLBI 데이터 스트림 입출력 구현)

  • Song, Min-Gyu;Kim, Hyo-Ryung;Kang, Yong-Woo;Je, Do-Heung;Wi, Seog-Oh;Lee, Sung-Mo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1109-1120
    • /
    • 2019
  • In the field of VLBI, If the quality of the connected network between the VLBI station and the correlation center is ensured, the existing inefficiency of repeatedly storing the observation data in each station and the correlation center can be overcome. In other words, the data center can be unified with the correlation center where data analysis is performed, which can improve data processing speed and productivity. In this paper, we design a massive VLBI data system that directly transmits and stores the observation data stream obtained from the VLBI station to the correlation center via the high - speed network KREONET. Based on this system, VLBI test observations confirmed that the observation data was stored perfectly in the recording system of the correlation center without a single packet loss.

Changes of Vascular Contractility of isolated Rat Aorta treated with Salt Stress (Salt 스트레스에 의한 흰쥐 적출대동맥의 수축력 변화양상)

  • 김종일;박태규;김중영
    • Journal of Environmental Science International
    • /
    • v.12 no.10
    • /
    • pp.1131-1136
    • /
    • 2003
  • To examine whether salt stress would alter or not contractility of isolated rat aorta, under anesthesia with sodium pentobarbital(50 mg kg-1 i.p.), male Sprague Dawley rats(300-330 g) were subjected to 0, 50, and 150 mM of sodium chloride at 37$^{\circ}C$ for 60 min. where as the sham group was left at modified Krebs-bicarbonate solution. To measure contractile response of vascular ring preparation isolated from rat was determined in organ bath and was recorded on physiograph connected to isometric transducer. And the strip was checked for expression of heat shock protein(Hsp) by Western blotting. One, three and eight hours later, we measured vascular contractility of isolated rat aorta treated with KCI, phenylephrine from organ bath study. The dose-vascular responses of potassium chloride and phenylephrine showed a little augmentation by NaCl concentration in the strips exposed to NaCl for 8 hours. And the response of relaxation induced by nitroprusside and acetylcholine was not influenced by NaCl stress in isolated aorta ring for 8 hours, respectively. Expression pattern of Hsp 70 of vascular muscle in isolated rat aorta showed a little increase in 150 mM NaCl group at 8 hours after NaCl treatment but not at 3 hours, and Hsp 60 expression of rat aorta was markedly increased in 50 mM NaCl group at 8 hours after NaCl treatment. Taken together, NaCl induced dose-and time dependent accumulation of the Hsp but not affected contraction of rat aorta. These data suggest that short term high salt stress was not sufficient to induce hypertension of rat aorta.

Effect of Panax Ginseng Alcohol Extract on the Contractility of Isolated Guinea Pig Tracheal Muscle (인삼(Panax Ginseng)주정추출액이 기관지 평활근의 수축력에 미치는 영향)

  • Hah, Jong-Sik;Lee, Myoung-Ho;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.11 no.2
    • /
    • pp.33-39
    • /
    • 1977
  • It has been reported that administration of Ginseng powder to the Guinea pig reduces anaphylactic shook induced by horse serum (Lee, 1939). However, Lee et al. (1960) and Paik et al. (1976) have demonstrated that Ginseng increases capillary permeabilites and histamine release from the mast cell. These facts suggest that Ginseng acts directly on the bronchial muscle causing it to dilate. Recently, a number of investigators(Kidakawa & Iwasiro 1963; Takagi et al. 1973) have reported that Ginseng reverses acetylcholine- or histamine- induced contraction in the isolated Guinea pig ileum. We, therefore, undertook the present study to examine if Ginseng relaxes the spasm of bronchial muscle induced by acetylcholine or histamine. We have also attempted to identify the mechanism of the Ginseng effect. Male Guinea Pig was sacrificed by a blow on the head, The trachea was removed and sectioned with scissors into about 12 rings. After the 'C' shaped ring of cartilage was sectioned the one end of ring was tied to the bottom of the incubation bath and the other end was connected to a force transducer (FTO 3C) to record tension on a Polygraph. When the antispasmodic action of Ginseng effect was first examined in the normal trachea which was not treated by the drug. And then the Ginseng effect was tested in the muscle treated by histamine hydrochloride, acetylcholine hydrochloride or barium chloride. The results indicate that Ginseng alcohol extract relaxes the contraction of isolated tracheal muscle induced by histamine $(1{\mu}g/ml{\sim}10{\mu}g/ml)$, acetylcholine $(1{\mu}g/ml{\sim}5{\mu}g/ml)$ and barium chloride (1.5 mg/ml). The mechanism of this action is in Pa.1 due to nonspecific antimuscarinic and antihistaminic effect and in part by predominant action in the adrenergic ${\beta}-receptor$ although the ${\alpha}-receptor$ is also involved. We, therefore, conclude that Ginseng can be act as a bronchodilator.

  • PDF