• Title/Summary/Keyword: Connected

Search Result 13,436, Processing Time 0.034 seconds

Design and Verification of Connected Data Architecture Concept employing DataLake Framework over Abyss Storage Cluster (Abyss Storage Cluster 기반 DataLake Framework의 Connected Data Architecture 개념 설계 및 검증)

  • Cha, ByungRae;Cha, Yun-Seok;Park, Sun;Shin, Byeong-Chun;Kim, JongWon
    • Smart Media Journal
    • /
    • v.7 no.3
    • /
    • pp.57-63
    • /
    • 2018
  • With many types of data generated in the shift of business environment as a result of growth of an organization or enterprise, there is a need to improve the data-processing efficiency in smarter means with a single domain model such as Data Lake. In particular, creating a logical single domain model from physical partitioned multi-site data by the finite resources of nature and shared economy is very important in terms of efficient operation of computing resources. Based on the advantages of the existing Data Lake framework, we define the CDA-Concept (connected data architecture concept) and functions of Data Lake Framework over Abyss Storage for integrating multiple sites in various application domains and managing the data lifecycle. Also, it performs the interface design and validation verification for Interface #2 & #3 of the connected data architecture-concept.

A Study on the Awareness and Need for Connected-Convergence Education among College Students in Health-Related Fields

  • Su-Hyeon Hong;Seung-Yeon Shin;Na-Hee Lee;Jin-A Lee;Seon-Im Cheon;Seol-Hee Kim
    • Journal of dental hygiene science
    • /
    • v.22 no.4
    • /
    • pp.233-240
    • /
    • 2022
  • Background: In modern society, rapid changes in the medical environment have required medical staff to access various information and be competent in active and effective problem-solving through collegial interactions. In line with these changes, universities are aiming to connect education. This study aimed to provide basic data of connected-convergence education by survey the awareness and needs of college students in health-related fields. Methods: This study included 122 college students from the health field. A survey regarding "the awareness and need of connected-convergence education" was conducted and general characteristics of the participants were collected from June to July 2022. Results: The awareness of connected-convergence education was low at 19.7%, but the intention to participate was high at 74.6%. Subject requirements were 18.0% for medical psychology, 13.5% for communication and counseling, 13.5% for medical artificial intelligence technology convergence, and 10.4% for sports health management. In the group showing high satisfaction with the major curriculum, the demand for connected education was also high. For efficient operation, it was investigated that it was necessary to secure specialized training courses, recognition of liberal arts credits, the right to register for courses equal to those of major students, and secure dedicated classrooms. Conclusion: Although the awareness and experience of connected-convergence education among the participants were low, the intention to participate was high. As such a plan to revitalize the university curriculum was required. It is timely to discuss the nurturing of convergence-type talents and multidisciplinary thinking skills. It is meaningful to provide basic data necessary for connected-convergence education in health-related fields at university. Universities should strive to enhance job competency in the health field by providing connected-convergence education based on student demands.

ENUMERATION OF GRAPHS WITH GIVEN WEIGHTED NUMBER OF CONNECTED COMPONENTS

  • Song, Joungmin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.54 no.6
    • /
    • pp.1873-1882
    • /
    • 2017
  • We give a generating function for the number of graphs with given numerical properties and prescribed weighted number of connected components. As an application, we give a generating function for the number of q-partite graphs of given order, size and number of connected components.

On the Characteristics of Series Connected Flip-Flop and Drive of Nixie Tube Operation (Series Connected Flip-Flop의 특성과 표시방전관의 구동에 대하여)

  • 정만영;안병성;김준호
    • 전기의세계
    • /
    • v.13 no.3
    • /
    • pp.21-27
    • /
    • 1964
  • A method of triggering a series connected complementary transister flip-flop is described. Also measurements have been made for the operation region with respect to the input pulse variation. This circuit is compared with a Eccles-Jordan flip-flop when it used as a Nixie tube driver of a neon lamp driyer.

  • PDF

REMARKS ON THE REIDEMEISTER NUMBERS FOR COINCIDENCE

  • Seoung Ho Lee;Sung Do Baek
    • Communications of the Korean Mathematical Society
    • /
    • v.13 no.1
    • /
    • pp.109-121
    • /
    • 1998
  • Let X,Y be connected, locally connected, semilocally simply connected and $f,g : X \to Y$ be a pair of maps. We find an upper bound of the Reidemeister number R(f,g) by using the regular coverig spaces.

  • PDF

A Review on the Grid-Connected Technology of the Distributed Energy Resources (분산형전원의 계통연계기술 리뷰)

  • Lee, Kyungsoo
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.371-372
    • /
    • 2014
  • This review focuses on grid-connected technology for distributed energy resources(DER). The grid-connected technology is categorized into three classifications: 1) protection function; 2) power quality improvement function; 3) grid stabilization fuction. Grid codes comparison of Japan, USA, EU and Korea is also described in the paper.

  • PDF

A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate (열교환기 관판의 전지작용부식과 방지에 관한 연구)

  • 임우조;홍성희;윤병두
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.344-350
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.

  • PDF

A Study on the Galvanic corrosion and its Protection on Heat Exchanger Tube Plate (열교환기 관판의 전지작용부식과 방지에 관한 연구)

  • U-J Lim;S-H Hong;B-D Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.345-345
    • /
    • 2001
  • This paper was studied on the characteristics of galvanic corrosion and its protection on heat exchanger tube plate in the sea water. In this paper, behavior of pitting corrosion of Ni-al bronze connected with Ti tube was measured af flow velocity of 0 m/s and 2.4 m/s. To protect galvanic corrosion, the protection characteristics of Ni-Al bronze connected with Ti tube by Zn-base alloys galvanic anode and hexagonal nylon insert was investigated. Main results obtained asre al follows: 1) The galvanic corrosion of Ni-Al bronze connected with Ti-tube is more active than single Ni-al bronze. 2) As the circuit resistance increase under the cathodic protection employing Zn-base alloys galvanic anode, Ni-al bronze connected with Ti tube is cathodically unpolarized. 3) The corrosion of Ni-Al bronze connected with Ti tube by nylon insert controls approximately 73% than not nylon insert.