• Title/Summary/Keyword: Conformity assessment

Search Result 102, Processing Time 0.024 seconds

Status and Perspective of Product Noise Labeling (소음표시제의 현황과 전망)

  • Kim, Dae-Joon;Lee, J.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.100-103
    • /
    • 2005
  • The aim of the product noise labeling is to harmonize the noise control act relating to noise emission standards, conformity assessment procedure, marking, technical documentation and collection of data concerning the noise emission in the environment of equipment for use outdoors. It will contribute to the smooth functioning of the internal market, while protecting human health and well-being.

  • PDF

Field Applicability Assessment of Controlled Low Strength Material for Sewer Pipe using Excavated Soil (굴착토를 활용한 유동화 채움재의 현장 적용성 평가)

  • Kim, Young-Wook;Lee, Bong-Chun;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.349-357
    • /
    • 2019
  • Controlled low strength material(CLSM) has been developed using variety of material such as excavated soil, industrial by-product and industrial waste. But theses research limited at laboratory test and failed at commercialization. So in this paper evaluates CLSM used excavated soil characteristics such as flowability, bleeding rate, early strength for following process and 28day strength for re-excavatability. Also, various mix proportion of CLSM by water-binder ratio and soil-binder ratio were evaluated in laboratory. And derive the optimized CLSM mix proportion for using at field application test by movable batch plant. After applying CLSM at trench, evaluate core sample strength and excavatability by shovel, pickax and excavator for verify re-excavation. Furthermore, measure the level change after casting CLSM to inspect subsidence stability. As results of these assessments, not only confirmed the characteristics of CLSM at field but the fillability around pipe and subsidence stability.

A Consciousness Structure Analysis for the Success Factors of Company Projects Using FSM (FSM을 이용한 기업프로젝트 성공요인의 의식구조분석)

  • Lee, Young-Joo;Hwang, Seung-Gook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.5
    • /
    • pp.720-724
    • /
    • 2009
  • This thesis analyze structure of consciousness of success factors of company project by applying FSM(Fuzzy Structural Modeling). FSM is a theory that implied fuzzy theory to ISM(Interpretive Structural Modeling) and is known to be more valid in recognizing a complex pluralistic value system and it is also designed to choose structure model that fits reality with when it is changed by parameter p and $\lambda$. It is desirable to conduct conformity assessment to complement even though selected structure model is considered as conformed because structure model is chosen without objective evaluation for conformity. Therefore, this paper present more objective structure model through conformity evaluation using structural equation modeling on success factors to achieve company project obtained by FSM and analyze the consciousness structure according to that structure.

Engineering Characteristics Assessment of Rapid Set Controlled Low Strength Material for Sewer Pipe Using Excavated Soil (굴착토를 활용한 속경성 유동성 채움재의 공학적 특성 평가)

  • Kim, Young-Wook;Lee, Bong-Chun;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.450-457
    • /
    • 2020
  • In this study, engineering characteristics such as flowability, segregation and compressive strength by age to derive fast hardening material mixing proportion using excavated soil. And based on optimal mixing proportion, field simulation experiment conducted in laboratory to examine the effectiveness of the method such as kelly ball drop test and soil penetration test for reviewing the following process. As as a result of evaluation, in case of kelly ball drop test and soil penetration test were securing the following process initiation time 3 hours after place CLSM. As results of these assessments, kelly ball drop test and soil penetration test were applicable for revewing following process in construction field besides unconfined compressive strength method.

Conformity Assessment and Test Method for Implementation of Web Services Compositions based on Choreography (코레어그래피 기반 웹 서비스 조합의 구현 적합성 평가 및 테스트 방법)

  • Kuk, Seung-Hak;Seo, Yong-Jin;Kim, Hyeon-Soo
    • Journal of Internet Computing and Services
    • /
    • v.13 no.1
    • /
    • pp.83-98
    • /
    • 2012
  • Recently Web services and SOA(Service Oriented Architecture) is widely used for an effective integration way of distributed applications. The service choreography is a way of service compositions to define workflows and the message exchange protocols among several partner ser-vices in the B2B business process environment. It defines the overall business process from a global perspective. However, it must be transformed into some kind of the executable form to implement service compositions, because it does not support an execution mechanism but is a de-clarative form. Therefore, the transformed executable model must be validated with the original choreography model to guarantee behavior equivalence. In this paper, we propose the conformity assessment with respect to service compositions method between the choreography model and the transformed executable model. And we suggest the test method to show behavior equivalence between them from a viewpoint of the dynamic execution.

A Study on the Relationship of Change of Mechanical Properties and Carbonyl Index Induced through Short-wavelength Ultraviolet Radiation (254 nm) for High Density Polyethylene (단파장 자외선(254 nm)에 노출된 고밀도 폴리에틸렌 수지의 카르보닐 지수(CI)와 기계적 물성 변화의 관계에 관한 연구)

  • Kim, Chang-Hwan;Shin, Jin-Yong
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.138-143
    • /
    • 2013
  • This paper studied the possibility to predict a mechanical property variation from changes in created carbonyl bands by irradiating the surface of high-density polyethylene with short-wavelength ultraviolet radiation of 254 nm to induce a fast chemical degradation. The meaning of this study lies in checking whether a mechanical property change with the same chemical property as the induced optical deterioration is caused by using a UVC lamp with high photon energy instead of optical deterioration via xenon arc light source and outdoor exposure test via natural sunlight requiring a long time. The mechanical strength of high-density polyethylene checked by a tensile test and a creep destruction test showed a similar tendency with CI changes. In particular, the yield strength and elongation had a close relationship with the exposure time to ultraviolet radiation. Accordingly, this paper presented a method to grasp the mechanical property change outdoors requiring a long time more fast through the relationship between the mechanical property change and the carbonyl index using a UVC lamp causing the fast surface degradation.

Conformity Assessment of Vertical Static Stiffness Test Method for Rail Pad (레일패드 정적 수직강성 시험방법의 적합성 평가)

  • Bae, Young-Hoon;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2015
  • The vertical static stiffness of rail pads or baseplate pads, which are important components in rail fastening systems for track safety, is a key factor to determine the total track stiffness and a guideline of quality control in the manufacturing process. The vertical static stiffness can be checked by laboratory testing: test methods are EN 13146-9 and KRS TR 0014, which are widely used in the railway field. In this paper, to correct some problems, namely the preloading step, the unloading level, and the holding time in the loading program in the vertical static stiffness test of EN 13146-9 and KRS TR 0014, domestic and foreign test standards of pads were analyzed and then certain schemes for a vertical static stiffness test were proposed. To assess the reliability of the proposed schemes, the vertical static stiffness tests were performed with 4 pads and the validity of the test results was estimated.

Decision Making Method based on Function and Performance Matrix Assessment Considering Design Change

  • Oh, Youngsuk;Chun, Jaeyoul;Cho, Jaeho
    • Architectural research
    • /
    • v.17 no.3
    • /
    • pp.83-91
    • /
    • 2015
  • A comprehensive understanding of functions and performances enables a selection of appropriate alternatives to the existing design and can prevent defective design. A performance-based design quality management can ensure successful project completion. This study proposes a new model for design quality management in order to prevent defective design and to minimize design change. The new quality management model defines the requirement about function and performance based on technical characteristic, and assesses suitability for design alternatives. This study attempts to propose a quality matrix assessment method that can compare the alternative design and requirements defined with the new quality management model. This method can judge conformity and suitability of design quality in accordance with the requirements configured.

Suggestion of the Post-Environmental Evaluation of Road-side Cut Slope after Revegetation Works (도로비탈면 녹화공사의 사후환경평가 항목 제언)

  • Kim, Tae-Kook;Kim, Nam-Choon;Kim, Eun-Bum;Koo, Min-Kyu
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.21 no.4
    • /
    • pp.75-86
    • /
    • 2018
  • This research was thereby made to study and analysis ecological, landscape, and stability qualities of roadside cut Slopes in expressways and national highways that went through revegetation works. Also, evaluation items and framework for integrated assessment of plant structure and restored state for the maintenance were suggested. Following is the summary of the result. firstly, for stabilization of introduced native plant species on roadside cut slops, assessment on the post-project environmental management through long-term monitoring and maintenance works must be made. It signifies a form of authentic recovery and restoration by the native plants. second, current evaluation framework on the test beds is well managed with clear evaluation standards and table while its method of assessing the post management with only test bed results lacks conformity with this study site. Newly developed evaluation framework on the post construction sites is estimated to be used as assessment standards on any roadside construction sites. Third, after site investigation distinction was observed among different revegetating construction types in the long-term perspective. Due to the different duration time of vegetation state between seed-spray measures(degraded in time) and layer-spray measure(maintained), the use of coarse straw-mat mulching work or Coir net was suggested in long term maintenance of cut slopes. forth, segmentation of post environmental assessment is organized into three large categories of "ecological", "stabile", and "landscape" qualities regarding post restoration quality and stability of slope through native plants with which categories marks 50, 30, 20 points of rates. fifth, components of the post environmental assessment were segmented in twelve categories driving results from former experimental construction and newly focused items on site. In the future, it is possible to propose a customized assessment method considering the location and location of construction work if the research on the application of post-environment assessment methods for road construction surface recording is conducted systematically.

Case Study on Risk Assessment of Railway Infrastructure Sections Using Acceptable Risk Matrix (위험도 매트릭스를 활용한 철도시설물 구간 위험도평가의 사례연구)

  • Shin, Duck-ho;Park, Chan-woo;Chae, Eunkyung;Lee, June-Seok
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.550-557
    • /
    • 2017
  • Owing to the established international standards for reliability and safety management of railways and the third-part conformity assessment implementation, quantitative risk assessment focusing on communication system related to railway safety has being implemented. The quantitative risk assessment starts from the establishment of quantitative RAMS requirements; the risk has to be maintained under an acceptable safety level. This paper introduces the risk assessment process based on international standards ; risk assessment was conducted using failure data for railway facilities for about 5.5 years. In addition, based on the results, a scientific risk management method for railway facilities is suggested.