• Title/Summary/Keyword: Cone penetrometer

Search Result 97, Processing Time 0.02 seconds

Comparison of Field Bearing Capacity Tests to Evaluate the Field Application of Dynamic Cone Penetrometer Test (동적 콘관입 시험의 현장적용성 평가를 위한 현장 지지력시험 상호 비교 연구)

  • Kim, Boo-Il;Jeon, Sung-Il;Lee, Moon-Sup
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.75-85
    • /
    • 2006
  • Plate Bearing Test(PBT) and California Bearing Ratio Test(CBR) usually have been used to evaluate the bearing capacity of sub-layer in pavement system. However, these tests have shortcomings for which man powers and time are spent greatly. Many researchers proposed a simple Dynamic Cone Penetrometer Test(DCP) to evaluate the bearing capacity of sub-layers in pavement system. This study performed several field bearing capacity tests(DCP, PBT, CBR, FWD) to evaluate field performance of DCP on sub-base and subgrade at four test sections simultaneously. The results showed that DCPI, $M_{FWD}$, and $PBT_K_{30}$ are highly correlated, but CBR and other test are not. This study proposed the following regression models between FWD, DCP, and PBT: $$M_{FWD}=993.10\Big(\frac{1}{DCPI}\Big)+33.95\;R^2=0.77$$ $$M_{FWD}=3.7533K_{30}+23.085\;R^2=0.69$$

  • PDF

Use of Dynamic Cone Penetrometer and Light-Weight Deflectometer for Quality Control on Subgrade Base (토공사 다짐품질 관리를 위한 동적콘관입시험 및 소형충격재하시험의 활용에 관한 연구)

  • Baek, Sung-Ha;Cho, Jin-Woo;Kim, Namgyu;Kim, Jin-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.55-67
    • /
    • 2022
  • This study applied the dynamic cone penetrometer test (DCPT) and light-weight deflectometer test (LWDT) to the quality control of subgrade base by performing DCPT, LWDT, and plate load test (PLT) at two earthwork sites. Although DCPT and LWDT were performed under the same conditions, the results showed significant variation with the test location. Because the measured value at the time of the initial blow, which varies depending on the test location, significantly influenced the test result. Thus, it was appropriate to ignore the first two blows as preliminary blows and use subsequent measurements as quality control indicators. In addition, DCPT, LWDT, and PLT results showed a high correlation under the same conditions. Especially regression analyses using averaged data for each experiment condition tended to yield significantly improved R2 values over individual point data sets. This indicates that average DCPT and LWDT values at various adjacent locations are better quality control indicators for subgrade bases than individual point values.

Alternative Cone Tip Resistance Analysis Method using Rescaled Range Analysis

  • Yu, Chan;Yoon, Chun-Gyeong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.7
    • /
    • pp.37-45
    • /
    • 2005
  • In this study, R/S analysis which was proposed by Mandelbrot & Wallis (1969) was applied to evaluate the presence of the fractal property in the cone tip resistance of in-situ CPT data. Hurst exponents (H) were evaluated in the range of 0.660$\sim$0.990 and the average was 0.875. It was confirmed that a cone tip resistance data had the characteristic of fractals and it was expected that cone tip resistance data sets are well approximated by a fBm process with an Hurst exponent near 0.875. It was also observed that the boundary between layers were obviously identified as a result of R/S analysis and it will be usage in practices.

Development and Verification of Static-Dynamic Cone Penetrometer (정동적 콘관입실험 장비의 개발과 검증)

  • Bae, Myeong-Ho;Yu, Jung-Dong;Kim, Ju-Han;SaGong, Myung;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.1
    • /
    • pp.77-86
    • /
    • 2011
  • The advanced geotechnical information has been required to determine the accurate design parameters for complex construction. However, the Standard Penetration Test (SPT), which has low reliability, has been used to estimate the subsurface condition in the field. The objective of this paper is development and application of the Static-Dynamic penetrometer, which detects the resistances in soft clay, sand and rock. The energy losses according to the rod connection methods (perfect or non-perfect connection, and number rods) are experimentally evaluated. The reflection and transmission ratios are used to investigate the energy loss by a simulation. The static-dynamic cone penetrometer, in which the accelerometers and strain gauges are installed on the cone tip and the rod head, is used to estimate the energy loss during penetration by impacts. The experimental and simulation studies show that the transferred energy through rods with non-perfect connection dramatically decreases. Furthermore, the transferred energy on the rod head is not the same as that on the cone tip. This study demonstrates that the energy loss should be evaluated on the cone tip.

Temperature Compensation on the Cone Tip Resistance by Using FBG Temperature Transducer (FBG센서를 이용한 콘 선단저항력의 온도영향 보상)

  • Kim, Rae-Hyun;Lee, Jong-Sub;An, Shin-Whan;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.10
    • /
    • pp.31-40
    • /
    • 2009
  • As the measurement of strain-gage type cone penetrometer is influenced by the temperature change during penetration, the temperature is a factor producing an error of the cone tip resistance. In this study, the 0.5 mm diameter temperature transducer and 7 mm diameter micro cone penetrometer are manufactured by using FBG sensors to evaluate the effect of temperature on the cone tip resistance. Design concepts include the cone configuration, sensor installation and the temperature compensation process. The test shows that the tip resistance measured by strain gauge is affected by the temperature change. The error of the tip resistance increases with an increase in temperature change, while the temperature effect on the tip resistance of FBG cone is effectively compensated by using FBG temperature transducer. Temperature compensated tip resistance of the strain gauge cone shows the good matched profile with FBG cone which performs real-time temperature compensation during penetration. This study demonstrates that the temperature compensation by using FBG sensor is an effective method to produce the more reliable cone tip resistance.

Performance Test of a Real-Time Measurement System for Horizontal Soil Strength in the Field

  • Cho, Yongjin;Lee, DongHoon;Park, Wonyeop;Lee, Kyouseung
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.304-312
    • /
    • 2016
  • Purpose: Soil strength has been measured using a cone penetrometer, which is making it difficult to obtain the spatial data required for precision agriculture. Our objectives were to evaluate real-time horizontal soil strength (RHSS) to measure soil strength in real time while moving across the field. Using the RHSS data, the tillage depth was determined, and the power consumption of a tractor and rotavators were compared. Methods: The horizontal soil-strength index (HSSI) obtained by the RHSS was compared with the cone index (CI), which was measured using a cone penetrometer. Comparison analysis in accordance with the measurement depth that increased at 5-cm interval was conducted using kriged maps at six sensing depths. For tillage control and evaluation of the power consumption, the system was installed with a potentiometer for tillage depth, a torque sensor from the rear axle, and a power take-off (PTO) shaft. Results: The HSSI was lower than the CI, but they were the same at 54.81% of the total grids for the 5-cm depth and at 3.85% for the 10-cm depth. In accordance with the recommended tillage map, tillage operations between 0 and 15 cm left 2.3% and 7% residue cover on the soil, and that between 20 and 10 cm covered a wider utilization of 3% and 18.4%, respectively. When the tillage depth was 15 cm, the comparison result of the power requirements between the PTO and rear axle in terms of control performance revealed that the maximum power requirements of the axle and PTO were 44.63 and 23.24 kW, respectively. Conclusions: An HSSI measurement system was evaluated by comparison with the conventional soil strength measurement system (CI) and applied to a tractor to compare the tillage power consumption. Further study is needed on its application to various farm works using a tractor for precision agriculture.

The practical aprication of Cone Pressuremeter, PMT, Vane tests to site investigation (Cone Pressuremeter, PMT, Vane 시험을 이용한 지반조사 사례연구)

  • Yi, Chang-Tok;Koo, Ja-Kap;Kim, Jong-Su;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.323-330
    • /
    • 1999
  • The concepts of mounting a pressuremeter module behind a cone penetrometer was applied in the early 1980s. The pressuremeter module is of 40mm diameter with length / diameter ratio of 10 inflated by nitrogen gas. This cone pressuremeter(CPM) is used to obtain the ground characteristics consisted of mainly silty, clay and sand. Field tests such as SPT, PMT, Vane tests are also carried out to understand the ground condition. Undisturbed samples are obtained to carried out Lah tests. The results of these field and lab tests are presented, discussed in detail, and compared with each others.

  • PDF

Development of Alternative Interpolation method of CPT Data using Fractal Theory (플랙탈 이론을 활용한 콘관입시험 결과의 새로운 보간법 개발)

  • Yu, Chan;Jung, Sung-Mo;Jung, Kyoung-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.179-188
    • /
    • 2006
  • In this study, R/S analysis which was proposed by Mandelbrot & Wallis(1969) was applied to evaluate the presence of the fractal property in the cone tip resistance of in-situ CPT data. Hurst exponents(H) were evaluated in the range of $0.660\sim0.990$ and the average was 0.875. It was confirmed that a cone tip resistance data had the characteristic of fractals and it was expected that cone tip resistance data sets are well approximated by a fBm process with an Hurst exponent near 0.875. It was also observed that the boundary between layers were obviously identified as a result of R/S analysis and it will be usage in practices.

  • PDF

A Study on Numerical Modeling of Dynamic CPT using Particle Flow Code (입자결합모델을 이용한 동적콘관입시험(DCPT)의 수치해석 모델링에 관한 연구)

  • You, Kwang Ho;Lee, Chang Su;Choi, Jun Seong
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-52
    • /
    • 2014
  • PURPOSES : To solve problems in current compaction control DCPT(Dynamic Cone Penetrometer Test), highly correlated with various testing methods, simple, and economic is being applied. However, it、s hard to utilize DCPT results due to the few numerical analyses for DCPT have been performed and the lack of data accumulation. Therefore, this study tried to verify the validation of numerical modeling for DCPT by comparing and analyzing the results of numerical analyses with field tests. METHODS: The ground elastic modulus and PR(Penetration Rate) value were estimated by using PFC(Particle Flow Code) 3D program based on the discrete element method. Those values were compared and analyzed with the result of field tests. Also, back analysis was conducted to describe ground elastic modulus of field tests. RESULTS : Relative errors of PR value between the numerical analyses and field tests were calculated to be comparatively low. Also, the relationship between elastic modulus and PR value turned out to be similar. CONCLUSIONS : Numerical modeling of DCPT is considered to be suitable for describing field tests by carrying out numerical analysis using PFC 3D program.

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (오염지반 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Yoo, Dong-Ju;Park, Jun-Boum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.330-337
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for delineation of subsurface contamination in situ, and then be supplemented with a minimum confirmatory sampling and laboratory testing program. While the resistivity measurement have potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements for delineating the subsurface contamination. This study is focused on verifying the applicability of resistivity and capacitance measurements on CPT module to provide information on contaminated subsurface by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination.

  • PDF