• Title/Summary/Keyword: Conductance method

Search Result 205, Processing Time 0.134 seconds

Electrical transport characteristics of deoxyribonucleic acid conjugated graphene field-effect transistors

  • Hwang, J.S.;Kim, H.T.;Lee, J.H.;Whang, D.;Hwang, S.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.482-483
    • /
    • 2011
  • Graphene is a good candidate for the future nano-electronic materials because it has excellent conductivity, mobility, transparency, flexibility and others. Until now, most graphene researches are focused on the nano electronic device applications, however, biological application of graphene has been relatively less reported. We have fabricated a deoxyribonucleic acid (DNA) conjugated graphene field-effect transistor (FET) and measured the electrical transport characteristics. We have used graphene sheets grown on Ni substrates by chemical vapour deposition. The Raman spectra of graphene sheets indicate high quality and only a few number of layers. The synthesized graphene is transferred on top of the substrate with pre-patterned electrodes by the floating-and-scooping method [1]. Then we applied adhesive tapes on the surface of the graphene to define graphene flakes of a few micron sizes near the electrodes. The current-voltage characteristic of the graphene layer before stripping shows linear zero gate bias conductance and no gate operation. After stripping, the zero gate bias conductance of the device is reduced and clear gate operation is observed. The change of FET characteristics before and after stripping is due to the formation of a micron size graphene flake. After combined with 30 base pairs single-stranded poly(dT) DNA molecules, the conductance and gate operation of the graphene flake FETs become slightly smaller than that of the pristine ones. It is considered that DNA is to be stably binding to the graphene layer due to the ${\pi}-{\pi}$ stacking interaction between nucleic bases and the surface of graphene. And this binding can modulate the electrical transport properties of graphene FETs. We also calculate the field-effect mobility of pristine and DNA conjugated graphene FET devices.

  • PDF

The effects of desensitizing agents, bonding resin and tooth brushing on dentin permeability, in vitro (지각과민 처치제 후 접착레진 처리가 상아질 투과도에 미치는 영향)

  • Hong, Seung-Woo;Park, No-Je;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.165-176
    • /
    • 2014
  • Purpose: The effects of desensitizing agent are often for a short duration. One of the reasons is believed to be wear of desensitizing agent by tooth brushing. To reduce the wear and make the duration longer, dental bonding resin was applied and the changes of dentin permeability after toothbrushing were measured. Materials and methods: Extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1 mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance and scanning electron microscope images (SEM) were compared and contrasted before and immediately after the application of desensitizing agent and bonding resin and then after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study; they were All-Bond 2, Seal & Protect, Gluma, and MS Coat. And Dentin/Enamel Bonding resin (Bisco Inc.) was used. The results of this study are as follows. Results: On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent and bonding resin. Compared with the specimens treated only with desensitizer, the specimens treated with All-Bond 2, Gluma, MS Coat and plus D/E bonding resin had a little increase in hydraulic conductance after 1, 2 and 6-week tooth brushing. In case of Seal & Protect, the specimens showed the same result only after 6-week tooth brushing. On examination of SEM, the dentinal tubule diameter had decreased after treatment of desensitizing agents and bonding resin. And the specimens treated with All-Bond2, Seal&Protect, Gluma, MS Coat and plus D/E bonding resin had an significant decrease in diameter of dentinal tubule after 6-week tooth brushing. Conclusion: According to the results of this study, it is effective to use bonding resin after application of desensitizer in reducing the wear by tooth brushing and making the duration longer. In this study, just 6-week tooth brushing was performed, and it is not enough to regard it as a long-term data. So further study is needed and more perfect method for treating dentin hypersensitivity should be developed.

Frequency-Dependent Line Capacitance and Conductance Calculations of On-Chip Interconnects on Silicon Substrate Using Fourier cosine Series Approach

  • Ymeri, H.;Nauwelaers, B.;Vandenberghe, S.;Maex, K.;De Roest, D.;Stucchi, M.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.209-215
    • /
    • 2001
  • In this paper a method for analysis and modelling of coplanar transmission interconnect lines that are placed on top of silicon-silicon oxide substrates is presented. The potential function is expressed by series expansions in terms of solutions of the Laplace equation for each homogeneous region of layered structure. The expansion coefficients of different series are related to each other and to potentials applied to the conductors via boundary conditions. In the plane of conductors, boundary conditions are satisfied at $N_d$ discrete points with $N_d$ being equal to the number of terms in the series expansions. The resulting system of inhomogeneous linear equations is solved by matrix inversion. No iterations are required. A discussion of the calculated line admittance parameters as functions of width of conductors, thickness of the layers, and frequency is given. The interconnect capacitance and conductance per unit length results are given and compared with those obtained using full wave solutions, and good agreement have been obtained in all the cases treated

  • PDF

Controllability of Structural, Optical and Electrical Properties of Ga doped ZnO Nanowires Synthesized by Physical Vapor Deposition

  • Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.148-151
    • /
    • 2013
  • The control of Ga doping in ZnO nanowires (NWs) by physical vapor deposition has been implemented and characterized. Various Ga-doped ZnO NWs were grown using the vapor-liquid-solid (VLS) method, with Au catalyst on c-plane sapphire substrate by hot-walled pulsed laser deposition (HW-PLD), one of the physical vapor deposition methods. The structural, optical and electrical properties of Ga-doped ZnO NWs have been systematically analyzed, by changing Ga concentration in ZnO NWs. We observed stacking faults and different crystalline directions caused by increasing Ga concentration in ZnO NWs, using SEM and HR-TEM. A $D^0X$ peak in the PL spectra of Ga doped ZnO NWs that is sharper than that of pure ZnO NWs has been clearly observed, which indicated the substitution of Ga for Zn. The electrical properties of controlled Ga-doped ZnO NWs have been measured, and show that the conductance of ZnO NWs increased up to 3 wt% Ga doping. However, the conductance of 5 wt% Ga doped ZnO NWs decreased, because the mean free path was decreased, according to the increase of carrier concentration. This control of the structural, optical and electrical properties of ZnO NWs by doping, could provide the possibility of the fabrication of various nanowire based electronic devices, such as nano-FETs, nano-inverters, nano-logic circuits and customized nano-sensors.

Performance-determining factors in flexible transparent conducting single-wall carbon nanotube film

  • Song, Young Il;Lee, Jung Woo;Kim, Tae Yoo;Jung, Hwan Jung;Jung, Yong Chae;Suh, Su Jeung;Yang, Cheol-Min
    • Carbon letters
    • /
    • v.14 no.4
    • /
    • pp.255-258
    • /
    • 2013
  • Flexible transparent conducting films (TCFs) were fabricated by dip-coating single-wall carbon nanotubes (SWCNTs) onto a flexible polyethylene terephthalate (PET) film. The amount of coated SWCNTs was controlled simply by dipping number. Because the performance of SWCNT-based TCFs is influenced by both electrical conductance and optical transmittance, we evaluated the film performance by introducing a film property factor using both the number of interconnected SWCNT bundles at intersection points, and the coverage of SWCNTs on the PET substrate, in field emission scanning electron microscopic images. The microscopic film property factor was in an excellent agreement with the macroscopic one determined from electrical conductance and optical transmittance measurements, especially for a small number of dippings. Therefore, the most crucial factor governing the performance of the SWCNT-based TCFs is a SWCNT-network structure with a large number of intersection points for a minimum amount of deposited SWCNTs.

Damage detection of reinforced concrete columns retrofitted with FRP jackets by using PZT sensors

  • Tzoura, Efi A.;Triantafillou, Thanasis C.;Providakis, Costas;Tsantilis, Aristomenis;Papanicolaou, Corina G.;Karabalis, Dimitris L.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.165-180
    • /
    • 2015
  • In this paper lead zirconate titanate transducers (PZT) are employed for damage detection of four reinforced concrete (RC) column specimens retrofitted with carbon fiber reinforced polymer (CFRP) jackets. A major disadvantage of FRP jacketing in RC members is the inability to inspect visually if the concrete substrate is damaged and in such case to estimate the extent of damage. The parameter measured during uniaxial compression tests at random times for known strain values is the real part of the complex number of the Electromechanical Admittance (Conductance) of the sensors, obtained by a PXI platform. The transducers are placed in specific positions along the height of the columns for detecting the damage in different positions and carrying out conclusions for the variation of the Conductance in relation to the position the failure occurred. The quantification of the damage at the concrete substrate is achieved with the use of the root-mean-square-deviation (RMSD) index, which is evaluated for the corresponding strain values. The experimental results provide evidence that PZT transducers are sensitive to damage detection from an early stage of the experiment and that the use of PZT sensors for monitoring and detecting the damage of FRP-retrofitted reinforced concrete members, by using the Electromechanical Admittance (EMA) approach, can be a highly promising method.

Automatic Nerve Activity to Physiologic Response in Adult With Psychiatric Disorder: A Systemic Review (성인 정신장애의 청각자극에 따른 생리학적 반응 측정에 대한 체계적 고찰)

  • Jung, Hye-Rim;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.9 no.1
    • /
    • pp.45-52
    • /
    • 2011
  • Objective : The aim of this study was to provide the method to measure physiologic response using equipments and auditory stimulation, and the physiologic response features of adult psychiatric disorders through a systemic review. Methods : The systemic review was executed using PubMed. The key words for search were "auditory stimulation, auditory startle, electromyograph, skin conductance, heart rate, psychiatric disorder, anxiety disorder, schizophrenia, depression". 8 studies were used for data analysis, and all of levels of evidence were level II. The substances of the review were subject(population), auditory stimulation, measure equipments and physiologic response features of psychiatric disorder. Results : 1. The subjects for the studies were anxiety disorder(4) and schizophrenia(4). 2. Auditory stimulation was used in 8 studies and visual stimulation with auditory stimulation was used in 2 studies to induce physiologic response. 3. Every study used electromyograph, and skin conductance was used in 2 studies and heart rate was used in 2 studies with electromyograph to measure physiologic response. 4. The subjects for the studies, schizophrenia and anxiety disorder(PTSD, OCD) have different physiologic response features with the normal control group. Conclusion : All studies used simple tones as an auditory stimulation and electromyograph to measure physiologic response. Psychiatric disorders indicated larger response, shorter and delayed habituation. The objective and systematic study using physiologic measure to investigate the sensory feature of psychologic disorders.

  • PDF

Simulation of Asymmetric Fuel Thermal Behavior Using 3D Gap Conductance Model (3 차원 간극 열전도도 모델을 이용한 핵연료봉의 열적 비대칭 거동 해석)

  • Kang, Chang Hak;Lee, Sung Uk;Yang, Dong Yol;Kim, Hyo Chan;Yang, Yong Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.249-257
    • /
    • 2015
  • A fuel assembly consists of fuel rods composed of pellets (UO2) and a cladding tube (Zircaloy). The role of the fuel rods in the reactor is to generate heat by nuclear fission, as well as to retain fission products during operation. A simulation method using a computer program was used to evaluate the safety of the nuclear fuel rods. This computer program has been called the fuel performance code. In the analysis of a light water reactor fuel rod, the gap conductance, which depended on the distance between the pellets and cladding tube, mainly influenced the thermomechanical behavior of the fuel rod. In this work, a 3D gap element was proposed to simulate the thermo-mechanical behavior of the nuclear fuel rod, considering the gap conductance. To implement the proposed 3D gap element, a 3D thermo-mechanical module was also developed using FORTRAN90. The asymmetric characteristics of the nuclear fuel rod, such as the MPS (missing pellet surface) and eccentricity, were simulated to evaluate the proposed 3D gap element.

Electrodermal Responses in Patients with Posttraumatic Stress Disorder by Motor Vehicle Accidents ; a Pilot Study (교통사고에 의한 외상 후 스트레스장애 환자의 피부 전기반응 : 예비 연구)

  • Seo, Ho-Jun;Jung, Young-Eun;Lee, Hye-Won;Moon, Hyun-Jin;Park, Ju-Mi;Kim, Seon-Kyung;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.3 no.2
    • /
    • pp.104-109
    • /
    • 2007
  • Objective : In the present study, we evaluated the differences between the skin electric conductance of patients with posttraumatic stress disorder (PTSD) and normal controls in order to determine the possibility of using skin electric conductance as a diagnostic measure. Method : The PTSD group included 14 subjects who were diagnosed with PTSD in St. Mary's Hospital after a motor vehicle accident, and the normal control group included 12 healthy subjects. The conductivity and capacitance of both groups were measured twice, and the data from each group was compared. Results : There was no significant difference in gender, but the patients in the PTSD group were significantly older than those in normal control group. The activity (conductivity) between the left head-left hand, right hand-right head, and right head-left head was significantly elevated in the PTSD group as compared with the normal control group. In addition, the reactivity (capacitance) between the right head-left head, left head-left hand, right hand-left hand, right hand-right foot, right foot-left foot, and left foot-left hand was significantly elevated in the PTSD group. Conclusion : In this study, the skin electric conductance of the patients with PTSD was significantly elevated in comparison with that of the healthy subjects. Although there were some limitations of this study, the results of this study suggested that skin electric conductance can be used to evaluate elevated psychophysiological responses in patients with PTSD. Future studies with more subjects and more structure are needed in order to confirm our results.

  • PDF

Analog MPPT Tracking MPP within One Switching Cycle for Photovoltaic Applications (One Switching Cycle 내에 최대전력점을 추종하는 태양광 발전의 아날로 MPPT 제어 시스템)

  • Ji, Sang-Keun;Kwon, Doo-Il;Yoo, Cheol-Hee;Han, Sang-Kyoo;Roh, Chung-Wook;Lee, Hyo-Bum;Hong, Sung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Tracking the Maximum Power Point(MPP) of a photovoltaic(PV) array is usually an essential part of a PV system. The problem considered by MPPT techniques is to find the voltage $V_{MPP}$ or current $I_{MPP}$ at which a PV array should operate to generate the maximum power output PMPP under a given temperature and irradiance. The MPPT control methods, such as the perturb and observe method and the incremental conductance method require microprocessor or DSP to determine if the duty cycle should be increased or not. This paper proposes a simple and fast analog MPPT method. The proposed control scheme will track the MPP very fast and its hardware implementation is so simple, compared with the conventional techniques. The new algorithm has successfully tracked the MPP, even in case of rapidly changing atmospheric conditions, and Has higher efficiency than ordinary algorithms.