• 제목/요약/키워드: Condensation Efficiency

검색결과 170건 처리시간 0.021초

Surface Treatment of Air Gap Membrane Distillation (AGMD) Condensation Plates: Techniques and Influences on Module Performance

  • Harianto, Rachel Ananda;Aryapratama, Rio;Lee, Seockheon;Jo, Wonjin;Lee, Heon Ju
    • Applied Science and Convergence Technology
    • /
    • 제23권5호
    • /
    • pp.248-253
    • /
    • 2014
  • Air Gap Membrane Distillation (AGMD) is one of several technologies that can be used to solve problems fresh water availability. AGMD exhibits several advantages, including low conductive heat loss and higher thermal efficiency, due to the presence of an air gap between the membrane and condensation wall. A previous study by Bhardwaj found that the condensation surface properties (materials and contact angle) affected the total collected fresh water in the solar distillation process. However, the process condition differences between solar distillation and AGMD might result in different condensation phenomena. In contrast, N. Miljkovic showed that a hydrophobic surface has higher condensation heat transfer. Moreover, to the best of our knowledge, there is no study that investigates the effect of condensation surface properties in AGMD to overall process performance (i.e. flux and thermal efficiency). Thus, in this study, we treated the AGMD condensation surface to make it hydrophobic or hydrophilic. The condensation surface could be made hydrophilic by immersing and boiling plate in deionized (DI) water, which caused the formation of hydrophilic aluminum hydroxide (AlOOH) nanostructures. Afterwards, the treated plate was coated using hexamethyldisiloxane (HMDSO) through plasma-enhanced chemical vapor deposition (PECVD). The result indicated that condensation surface properties do not affect the permeate flux or thermal efficiency significantly. In general, the permeate flux and thermal efficiency for the treated plates were lower than those of the non-treated plate (pristine). However, at a 1 mm and 3 mm air gap, the treated plate outperformed the non-treated plate (pristine) in terms of permeate flux. Therefore, although surface wettability effect was not significant, it still provided a little influence.

표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구 (Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio)

  • 성욱주;조수;장철용;이진성;백상훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF

운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성 (Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters)

  • 윤정인;손창효;백승문;김현주;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.580-585
    • /
    • 2012
  • R744용 해양온도차 발전 시스템의 작동변수에 대한 기초 설계자료를 제공하고자 증발열량, 응축열량, 전체일량, 효율에 대한 사이클 성능을 분석하였다. 본 연구에서 고려된 작동변수는 R744 해양온도차 발전 사이클의 과열도, 과냉각도, 응축온도, 증발온도 등이다. 주요 결과를 요약하면 다음과 같다. R744의 증발열량은 과열도와 과냉각도가 증가할수록 증가하는 반면, 응축온도가 증가할수록 감소한다. 전체일량은 R744의 과열도와 과냉각도와 함께 증가하나 증발온도는 증가할수록 감소한다. 그리고 효율은 과열도와 과냉각도가 증가할수록 증가하는 반면, 응축온도는 감소한다. 그러므로 R744용 해양온도차 발전 시스템의 증발열량, 응축열량, 전체일량, 효율은 과열도, 과냉각도, 응축온도, 증발온도, 펌프와 터빈 효율에 영향을 받는 것을 알 수 있었다. 따라서 R744용 해양온도차 발전 시스템의 설계시에는 이러한 영향을 면밀하게 파악하여야 한다.

시스템 축소기법이 적용된 역섭동법을 이용한 손상탐지 (System Condensation Technique-Based Inverse Perturbation Method of Damage Detection)

  • 최영재;이우식
    • 한국항공우주학회지
    • /
    • 제30권7호
    • /
    • pp.98-104
    • /
    • 2002
  • 본 연구에서는 역섭동법을 이용한 손상탐지의 효율을 개선하는 목적으로 시스템 축소기법을 사용하였다. 이 방법은 손상탐지의 미측정 자유도를 측정된 자유도로 변환하여 역섭동법의 계산효율이 향상되는 장점이 있으나, 부정확한 자유도의 변환으로 수치적인 안정성이 저하될 수 있다. 따라서 자유도 변환식을 수치해법 과정에서 반복적으로 개선하는 방법과, 매우 정확한 accelerated improved reduced system (AIRS) 축소법의 사용으로 역섭동법의 수치적 불안정성을 해결하였다.

The transient and frequency response analysis using the multi-level system condensation in the large-scaled structural dynamic problem

  • Baek, Sungmin;Cho, Maenghyo
    • Structural Engineering and Mechanics
    • /
    • 제38권4호
    • /
    • pp.429-441
    • /
    • 2011
  • In large-scale problem, a huge size of computational resources is needed for a reliable solution which represents the detailed description of dynamic behavior. Recently, eigenvalue reduction schemes have been considered as important technique to resolve computational resource problems. In addition, the efforts to advance an efficiency of reduction scheme leads to the development of the multi-level system condensation (MLSC) which is initially based on the two-level condensation scheme (TLCS). This scheme was proposed for approximating the lower eigenmodes which represent the global behavior of the structures through the element-level energy estimation. The MLSC combines the multi-level sub-structuring scheme with the previous TLCS for enhancement of efficiency which is related to computer memory and computing time. The present study focuses on the implementation of the MLSC on the direct time response analysis and the frequency response analysis of structural dynamic problems. For the transient time response analysis, the MLSC is combined with the Newmark's time integration scheme. Numerical examples demonstrate the efficiency of the proposed method.

Thermal Resistance and Condensation in the Light-frame Timber Wall Structures with Various Composition of Insulation Layers

  • Jang, Sang Sik;Lee, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권4호
    • /
    • pp.533-542
    • /
    • 2019
  • As energy costs increase, more people has become interested on energy efficiency and savings in residential buildings. The two main subjects related to energy in residential buildings are insulation and condensation. There are two approaches to prevent condensation; increasing air tightness and maintaining the temperature inside of the wall structure over the dew point, which is in turn related to insulation. Even though the Korean government has highlighted the importance of energy efficiency for residential housings, and in spite of the customers' demands, the timber construction industry is still using conventional light-frame construction without even trying to improve energy efficiency. In this study, various types and combinations of wall structures were tested under cold outdoor and warm indoor temperatures to analyse the temperature gradients and to determine the possible sites of condensation in the wall structures. In addition to the experimental tests, three theoretical models were developed and their estimations of temperature change through the wall structure were compared with the actual measurements to evaluate accuracy of the models. The results of the three models agree relatively well with the experimental values, indicating that they can be used to estimate temperature changes in wall structures. The theoretical analysis of different insulation layers' combinations show that condensation may occur within the mid-layer in the conventional light-frame wall structures for any combination of inner-, mid-, and outer-layers of insulation. Therefore, it can be concluded that the addition of an inner and outer insulation layer or increasing the thickness of insulation may not be adequate to prevent condensation in the wall structure without preventing penetration of warm moist air into the wall structure.

집진효율 향상을 위한 미세 에어로졸 입자의 응축에 의한 성장 연구 (Condensational Growth of Fine Aerosol Particles to Increase Precipitation Efficiency)

  • 한상우;황정호
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1069-1076
    • /
    • 2000
  • As the environmental problems grow, the regulation of the pollutants emitted from power plants increases. Most of the pollutants in particle phase are removed by particle removal facilities, but fine particles between 0.1 micron and I micron in diameter have a low removal efficiency compared to particles in other size ranges. Therefore the present concern has concentrated on the removal of those fine particles. The purpose of this study is to grow fine particles by condensation to the range larger than I micron. Theoretically the general dynamic equation is solved with an assumption that the particle size follows a log-normal distribution to calculate the temporal behavior of the size distribution. Experiments have been carried out to compare the results with the theoretical predictions. Particles grown by condensation are sampled by impactors and observed with SEM photographs.

액적 표면에서 증발 및 응축을 고려한 곡면 형상 액적 제거장치의 제거 효율에 대한 수치 해석 (Numerical Analysis on Removal Efficiency of Water Droplets in a Curved Vane Mist Eliminator with Consideration of Evaporation and Condensation at Surface of Droplets)

  • 송동근
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.135-143
    • /
    • 2016
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For accurate understanding of removal process in a curved vane mist eliminator, a numerical model including turbulent dispersion, evaporation and condensation of water vapor at surface of droplets is required. A two-stage curved vane mist eliminator has been modeled, and fluid flow of mixture of air and water vapor and droplet trajectories were solved simultaneously with taking into account two-way coupling. Removal efficiency of droplets with various inlet condition of relative humidities (RH, 40%, 90%, and 100%) were compared. As RH increased, the effect of evaporation decreased and inertial separation efficiencies of droplets obtained increased especially for droplets of diameter below 10 micrometers.

3D-based equivalent model of SMART control rod drive mechanism using dynamic condensation method

  • Ahn, Kwanghyun;Lee, Kang-Heon;Lee, Jae-Seon;Chang, Seongmin
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1109-1114
    • /
    • 2022
  • The SMART (System-integrated Modular Advanced ReacTor) is an integral-type small modular reactor developed by KAERI (Korea Atomic Energy Research Institute). This paper discusses the feasibility and applicability of a 3D-based equivalent model using dynamic condensation method for seismic analysis of a SMART control rod drive mechanism. The equivalent model is utilized for complicated seismic analysis during the design of the SMART. While the 1D-based beam-mass equivalent model is widely used in the nuclear industry for its calculation efficiency, the 3D-based equivalent model is suggested for the seismic analysis of SMART to enhance the analysis accuracy of the 1D-based equivalent model while maintaining its analysis efficiency. To verify the suggested model, acceleration response spectra from seismic analysis based on the 3D-based equivalent model are compared to those from the 1D-based beam-mass equivalent model and experiments. The accuracy and efficiency of the dynamic condensation method are investigated by comparison to analysis results based on the conventional modeling methodology used for seismic analysis.

Automated static condensation method for local analysis of large finite element models

  • Boo, Seung-Hwan;Oh, Min-Han
    • Structural Engineering and Mechanics
    • /
    • 제61권6호
    • /
    • pp.807-816
    • /
    • 2017
  • In this paper, we introduce an efficient new model reduction method, named the automated static condensation method, which is developed for the local analysis of large finite element models. The algebraic multilevel substructuring procedure is modified appropriately, and then applied to the original static condensation method. The retained substructure, which is the local finite element model to be analyzed, is defined, and then the remaining part of the global model is automatically partitioned into many omitted substructures in an algebraic perspective. For an efficient condensation procedure, a substructural tree diagram and substructural sets are established. Using these, the omitted substructures are sequentially condensed into the retained substructure to construct the reduced model. Using several large practical engineering problems, the performance of the proposed method is demonstrated in terms of its solution accuracy and computational efficiency, compared to the original static condensation method and the superelement technique.