본 연구에서는 압축공기에너지 저장 공동의 콘크리트 플러그 최적 형상을 조사하기 위해 플러그 형상에 따른 저장 공동의 안정성을 수치해석적으로 평가하였다. 고려한 플러그 형상은 원통형, 암반에 근입된 원통형, 테이퍼형, 쐐기형이었고, 강도감소법에 의한 안전율과 압축 공기의 압력으로 인해 콘크리트에 발생하는 항복 영역의 부피비를 토대로 안정성을 분석하였다. 안정성 분석 결과, 암반에 근입된 원통형과 테이퍼형 플러그가 원통형과 쐐기형 플러그보다 역학적으로 더 안정한 것으로 분석되었다. 그러나 암반에 근입된 플러그의 경우 플러그와 암반이 접촉하는 부분에서 응력 집중이 발생하여 암반에 근입된 원통형 플러그보다는 테이퍼형 플러그 가 최적의 형상인 것을 확인하였다.
The stability and safety of concrete plug structure of diversion tunnel is crucial for the impoundment of upstream reservoir in hydropower projects. The ongoing Wudongde hydropower plant in China plans to adopt straight column plugs and curved column plugs to replace the traditional expanded wedge-shaped plugs. The performance of the proposed new plug structures under high water head is then a critical issue and attracts the attentions of engineers. This paper firstly studied the joint bearing mechanism of plug and surrounding rock mass and found that the quality and mechanical properties of the interfaces among plug concrete, shotcrete, and surrounding rock mass play a key role in the performance of plug structures. By performing geophysical and mechanical experiments, the contact state and the mechanical parameters of the interfaces were analyzed in detail and provide numerical analysis with rational input parameters. The safety evaluation is carried out through numerical calculation of plug stability under both construction and operation period. The results indicate that the allowable water head acting on columnar plugs is 3.1 to 7.4 times of the designed water head. So the stability of the new plug structure meets the design code requirement. Based on above findings, it is concluded that for the studied project, it is feasible to adopt columnar plugs to replace the traditional expanded wedge-shaped plugs. It is hoped that this study can provide reference for other projects with similar engineering background and problems.
압축공기를 활용한 가스터빈 발전방식(CAES-G/T)은 태양열이나 풍력과 같은 신재생 에너지의 출력 변동성을 조절하는 유력한 수단 중 하나로 고려되고 있다. 국내에서 CAES 발전이 실용화된다면 지질여건상 암반터널식이 채택될 가능성이 크다. 암반터널식 CAES 시설에서는 압축공기 저장공간을 밀폐시키기 위한 콘크리트 플러그의 설치가 필요하므로 플러그의 형상과 크기를 결정하는 것이 중요한 설계변수가 된다. 파괴에 대한 안전율 분포와 접촉부 접촉압력 분포 분석을 통해 2가지 형태의 콘크리트 플러그에 대한 안정성 평가를 수행하였다. 주어진 지질조건에서는 테이퍼형 플러그가 쐐기형 플러그에 비해 구조적으로 안정한 것으로 나타났다. 쐐기형 플러그의 경우 측면 접촉부에서 분리현상이 예측되었고 이러한 분리면에서 압축공기의 누출 가능성과 마찰저항의 감소가 발생할 수 있음을 보여주었다.
한국암반공학회 2000년도 암반공학문제의 수치해석(Numerical Analysis in Rock Engineering Problems)
/
pp.93-103
/
2000
지하저장공동에 설치되는 콘크리트 플러그는 가능한 모든 하중조건에 대해 안정하게 유지됨은 물론 저장된 유류의 외부 유출과 지하수의 과다 유입을 방지하는 기능을 수행하여야 하므로 지하 유류비축기지의 건설 및 운영 단계에서 매우 중요한 역할을 한다. 플러그가 시공되고 나면 외부와의 접촉이 모두 차단되게 되므로 플러그가 그 기능을 제대로 발휘하기 위해서는 설계단계에서부터 역학적 및 수리적 고려가 이루어져야한다. 따라서 본 연구에서는 2차원 및 3차원 유한 차분프로그램인 FLAC과 FLA $C^{3D}$를 사용하여 플러그에 대한 역학적 및 수리적 해석을 실시하였다. 먼저 측압계수의 변화, 심도의 변화, 플러그의 형상변화, 암반과 콘크리트 접촉면의 상태변화, 굴착손상권의 발생 등 다양한 조건하에서 플러그의 거동 변화에 대한 역학적 해석을 실시하였으며, 2차원 해석조건과 동일한 조건을 가진 3차원 모델을 구성하여 그 결과를 2차원 해석과 비교, 검토하였다. 또한 플러그의 쐐기깊이 변화에 따른 수리해석을 실시하여 그 결과를 비교하였다.다.
지하저장공동에 설치되는 콘크리트 플러그는 기능한 모든 하중조건에 대해 안정하게 유지됨은 물론 저장된 유류의 외부 유출과 지하수의 과다 유입을 방지하는 기능을 수행하여야 하므로 지하 유류 비축기지의 건설 및 운영 단계에서 매우 중요한 역할을 한다. 플러그가 시공되고 나면 외부와의 접촉이 모두 차단되게 되므로 플러그가 그 기능을 제대로 발휘하기 위해서는 설계단계에서부터 역학적 및 수리적 고려가 이루어져야 한다. 따라서 본 연구에서는 2차원 및 3 원 유한 차분 프로그램인 FLAC 과 FLA $C^{3D}$를 사용하여 플러그에 대한 역학적 및 수리적 해석을 실시하였다. 먼저 측압계수의 변화, 심도의 변화, 플러그의 형상변화, 암반과 콘크리트 접촉면의 상태변화, 굴착손상권의 발생 등 다양한 조건 하에서 플러그의 거동 변화에 대한 역학적 해석을 실시하였으며, 2차원 해석조건과 동일한 조건을 가진 3차원 모델을 구성하여 그 결과를 2차원 해석과 비교, 검토하였다. 또한 플러그의 쐐기깊이 변화에 따른 수리해석을 실시하여 그 결과를 비교하였다.다.
최근 콘크리트 구조물에 충격하중, 폭발하중 등 극한의 외력이 작용하는 경우가 빈번하게 발생하고 있다. 이 연구에서는 강섬유보강 RC보와 carbon FRP 시트를 이용하여 보강한 RC보를 이용하여 충격실험을 진행하였다. 강섬유보강 RC보의 경우 0.75%부피비로 강섬유를 혼입하였으며 carbon FRP 시트의 경우 에폭시 레진을 이용하여 보강을 한후 보 부재를 완성하였다. FRP 시트 보강은 부재의 하단을 휨 보강하였으며 충격하중이 부재에 작용할 때 발생하는 shear-plug 균열을 제어하기 위하여 충격하중이 가해지는 국부에 CFRP 전단보강을 실시하였다. 실험진행은 drop-weight test 방식으로 직접 기기를 만들어 실행하였다. 각각의 부재에 단계별로 충격하중을 가하여 실험을 진행하였으며 균열과 균열폭을 측정하였다. 실험결과 강섬유보강 RC보가 일반 RC보에 비하여 균열폭 및 shear-plug 균열제어 그리고 스폴링파괴에 더 높은 성능을 나타내었다. FRP로 부재의 하단을 휨 보강한 부재의 경우 균열의 제어에 어느정도 효과를 나타내고 있으나 충격하중이 가해질 시 콘크리트와 FRP 시트의 부착면에서 박리파괴가 빠르게 진행되었다. FRP 시트로 부재의 하단과 측면을 CFRP로 휨, 전단보강한 부재의 경우 shear-plug 균열제어에 가장 높은 저항성능을 보이고 있음을 확인할 수 있었다. 하지만 충격하중이 보강이 이루어지지 않은 부분에 작용할 경우 오히려 보강이 되지 않은 RC보에 비하여 콘크리트 스폴링 파괴에 더 취약함을 알 수 있었다.
To determine the seismic applicability of a long-span railway concrete upper-deck arch bridge with concrete-filled steel-tube (CFST) rigid skeleton ribs, some fundamental principles and seismic approaches for long-span bridges are investigated to update the design methods in the current Code for Seismic Design of Railway Engineering of China. Ductile and mixed isolation design are investigated respectively to compare the structural seismic performances. The flexural moment and plastic rotation demands and capacities are quantified to assess the seismic status of the ductile components. A kind of triple friction pendulum (TFP) system and lead-plug rubber bearing are applied simultaneously to regularize the structural seismic demands. The numerical analysis shows that the current ductile layout with continuous rigid frame approaching spans should be strengthened to satisfy the demands of rare earthquakes. However, the mixed isolation design embodies excellent seismic performances for the continuous girder approaching span of this railway arch bridge.
본 실험적 연구는 고속 비상체 충돌 시 UHPC 외장재의 내충격성을 파악하는데 그 목적이 있다. 이 연구에서는 두께를 주요 변수로 UHPC과 화강암 패널 실험체에 고속충격을 가하여 실험체의 성능을 비교하였으며, 배면의 변형률을 기록하였다. UHPC는 외관이 우수하였으며, 내충격성도 화강암에 비해 우수하여 외장재로 사용하기에 적당하다고 판단된다. 비상체가 시험체에 충돌한 후 압축파가 배면에 도달하고 그 후 자유단 지점을 중심으로 인장파가 발생하여서 배면파괴를 일으킨 것으로 사료된다. 이러한 배면파괴 발생 메커니즘은 변형률 기록이 압축파구간, 보합구간, 인장구간으로 나누어지는 것을 통해 알 수 있다. 관통파괴 형태를 살펴보면 고속 충돌 시 전단력이 배면에 작용하여 파괴가 발생되는 shear plug 현상이 나타난 것으로 판단된다. 즉 충격하중에 대하여 배면의 파괴는 전단력과 인장응력에 의해 동시에 영향을 끼쳐 발생한 것으로 사료된다.
The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.
In this study, in order to investigate the effects of wall roughness on the hydraulic characteristics of chlorine contactor, CFD simulation and tracer tests were conducted for both of reactors whose walls are made of concrete and lined with PE(Poly Ethylene). In the case of walls contacted with water being lined with PE (relatively lower roughness), the flow within reactor is closer to plug flow than that in the case of concrete walls (relatively higher roughness). Especially, the longer tail of C-curve from the results of transient CFD simulation can tell that Morill index in the case concrete walls is much higher than that in the case of walls be lined with lower roughness material.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.