• Title/Summary/Keyword: Concrete Wall Panel

Search Result 132, Processing Time 0.029 seconds

P.C. 대형판 구조의 수평접합부 압축거동에 관한 실험적 연구 (Experimental Study on the Compressive Behavior of Horizontal Joint in Precast Concrete Large Panel Structure)

  • 조양호;이한선;김현산
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.19-24
    • /
    • 1994
  • Four types of horizontal joint were tested to investigate the difference with regards to the compressive behavior and strength. These include wedge-type joints (i)with and (ii)without transverse reinforcement against splitting failure of the panel concrete, and wedge-type joints (iii)with different widths of joint concrete (6cm vs 8cm) and (iv)closed platform joint. It was shown that the compressive strength of wedge-type joint is about 10% higher than that of closed-type (platform) joint. But the effect of transverse reinforcement and joint concrete widths on the strength of the joints turned out be negligible. Also, the moduli of elasticity in panel and joint are compared and the equivalent moduli of the whole wall are derived.

  • PDF

상용프로그램(ABAQUS)을 이용한 원전 격납건물 RC Panel의 극한 인장해석 (Ultimate Tensile Analysis of Reinforced Concrete Containment Panel by using ABAQUS Program)

  • 김남식;정대성;김광수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.577-584
    • /
    • 2003
  • Tension tests of half-thickness concrete containment wall elements and material tests were conducted to derive a crack pattern and constitutive law of concrete. Main test variables are reinforcement ratio and the applied load ratio in two direction, and its effect on the behavior of reinforced concrete panel subjected to biaxial tension is investigated. Based on the test results, analytical expression is derived for the stress-strain relationship of concrete in tension. Ultimate analyses of reinforced concrete panels are carried out by a general purpose structural analysis computer program(ABAQUS), and its results are compared with the test results. The present analysis focuses on the effects of pre-analysis prior to test of specimens. These ultimate tensile analyses as pre-analysis are essential and important to design an effectual scheme of test.

  • PDF

P.C 대형판넬 부분구조물의 Quasi-Static 실험연구 (Quasi-Static Test of Precast Concrete Large Panel Subassemblage)

  • 최정수;이한선;김우;홍갑표
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.73-78
    • /
    • 1990
  • Large panel building systems are composed of vertical wall panels which support horizontal roof and floor panels to form a box like structure. The simplecity of the connections, which makes precast concrete economically viable, causes a lack of continuity in stiffness, strength and ductility. This precast concrete large panel systems typically have weak connection regions. Three types of 2-story full-scale precast concrete subassemblages were tested under reversed cyclic loading. The seismic resistance capacity and failure mode of each system are compared in connection with the characteristics of joint connection details.

  • PDF

대형재하시험을 통한 원지반 부착식 패널옹벽의 거동특성 (Behavior Characteristics of Precast Concrete-Panel Retaining Wall Adhered to In-situ Ground through Large Scaled Load Test)

  • 신윤철;민경남;김진희;안태봉
    • 한국지반환경공학회 논문집
    • /
    • 제17권11호
    • /
    • pp.45-53
    • /
    • 2016
  • 패널식 옹벽은 지보재를 통한 선지보 개념으로 프리캐스트 패널과 체결하여 원지반 강도를 최대한 보호하며 보강하는 공법이다. 최근 건설공사에서 대규모 깎기비탈면의 형성에 따른 토공량 증가와 환경 훼손을 최소화하고 용지제한에 따른 토지의 효율적인 이용을 위해 패널식 옹벽의 적용이 증가하고 있는 추세이다. 원지반 부착식 패널옹벽은 자연암반 질감을 갖는 프리캐스트 콘크리트 패널을 사용하여 경관성을 향상시키고 완전한 Top-Down 시공법을 구현하도록 개발된 공법으로 수직절취와 패널의 원지반 직접부착이 가능해 비탈면 이완을 최소화하고 터파기 및 되메우기 공종을 배제하여 시공성을 개선하였다. 본 연구는 현장시험시공을 수행하여 수직절취 및 Top-Down에 대한 시공성을 확인하고, 대형재하시험과 하중단계별 계측결과를 분석하여 원지반 부착식 패널옹벽의 거동특성을 분석하였다.

전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석 (An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors)

  • 강동화;강동화;신동현;김형준
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

내진성능이 개선된 PC구조벽체의 개발 (Development of Precast Concrete Structural Wall which Can Assure Reliable Seismic Performance)

  • 강수민;오재근;김욱종;이도범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.459-460
    • /
    • 2009
  • PC(Precast Concrete)구조시스템은 건식화 조립식 공법으로 구조물 건설에 있어 공기, 노동력 절감 등의 여러 장점을 가지고 있다. 하지만 구조벽체의 경우 PC화할 경우 접합부의 내진성능이 부족하여 구조벽체를 PC화하여 적용하는 경우는 드물다고 할 수 있다. 본 연구에서는 이러한 점을 감안하여 접합부 성능을 개선하여 횡력저항요소로 사용가능한 PC구조벽체를 고안하였다. 제안된 PC구조벽체는 지진발생 시 충분한 강도와 변형능력을 확보할 수 있도록 하였다. 제안된 PC구조벽체의 실험결과, 제안된 PC구조벽체는 충분한 내진성능을 확보할 수 있는 것으로 나타났다.

  • PDF

경량기포콘크리트 재료를 활용한 커튼월 구법에 관한 일본 특허기술의 분석 연구 (Patent Investigations and Analysis for the Curtain Wall System based on the Autoclaved Lightweight Concrete(ALC))

  • 김영호
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권1호
    • /
    • pp.81-88
    • /
    • 2012
  • According to the survey results of the Ministry of Land, Transport and Maritime Affairs in the end of December 2011, the residential buildings was reported as 67.3% of 4,529,464 buildings. Reflected in the national energy policy, the residential building is expected that greater energy savings. To have realized the Passive House Project used the Autoclaved Lightweight Concrete(ALC) material on exterior wall, we take advantage of a very large energy savings. Therefore, this study investigate the patent documents of three major companies, SUMITOMO, CLION, ASAHI KASEI, in Japan. and analyze technical flow and benchmarking patent. As a result, the Sliding method or the Rocking method of ALC panels how to install is to be superior to high-performance drift and safety by a earthquake. And the embedded anchor in panel needs to improve the shape and the strength of bearing. Thus installation technology of the ALC exterior wall investigated in japanese patent documents is expected to the fastening units and anchors.

Seismic behavior of steel frames with lightweight-low strength industrialized infill walls

  • Zahrai, Seyed Mehdi;Khalili, Behnam Gholipour;Mousavi, Seyed Amin
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1273-1290
    • /
    • 2015
  • JK wall is a shear wall made of lightweight EPS mortar and reinforced with a 3-D galvanized steel mesh, called JK panel, and truss-like stiffeners, called JK stiffeners. Earlier studies have shown that low strength lightweight concrete has the potential to be used in structural elements. In this study, seismic contribution of the JK infill walls surrounded by steel frames is numerically investigated. Adopting a hybrid numerical model, behavior envelop of the wall is derived from the general purpose finite element software, Abaqus. Obtained backbone would be implemented in the professional analytical software, SAP2000, in which through calibrated hysteretic parameters, cyclic behavior of the JK infill can be simulated. Through comparison with earlier experimental results, it turned out that the proposed hybrid modeling can simulate monotonic and cyclic behavior of JK walls with good accuracy. JK infills have a panel-type configuration which their dominant failure mode would be ductile in flexure. Finally technical and economical advantages of the proposed JK infills are assessed for two representative multistory buildings. It is revealed that JK infills can reduce maximum inter-story drifts as well as residual drifts at the expense of minor increase in the developed base shear.

Nailing System으로 보강된 억지벽체공법에 관한 연구 (A Study on the Slide Suppressor Wall Method Reinforced with Nailing System)

  • 김홍택;강인규
    • 한국지반공학회지:지반
    • /
    • 제11권1호
    • /
    • pp.79-100
    • /
    • 1995
  • 본 연구에서는 Wright 등이 제안한 산사태 억지벽체공법에, nailing system을 추가한 새로운 형태의 사면보강공법을 제시하였다. 이를 위해, nail로 보강된 콘크리트판넬에 작용하는 토압산 정법의 제시 및 억지말뚝 해석법의 정림 등이 이루어 졌다. 또한 제시된 토압산정법을 토대로, nail의 효율적인 배치형태 및 설치각도 등에 대한 분석과, 콘크리트판넬 및 억지말뚝으로 구성된 억지벽체의 최적설치위치에 관한 분석이 수행되었다. 이외에도 설계예를 통해, Wright 등의 제안방법과의 비교, 억지말뚝 상호간섭작용의 영향검토 등이 수행되었다.

  • PDF

고주파 접착기를 사용한 복합석재판의 콘크리트 벽체 부착 시공 (The Construction Method which attached Complex Stone Panel to Concrete Wall using High-Frequency Holt-Melt Machine)

  • 오창원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.45-49
    • /
    • 2010
  • The contamination(stain phenomenon) of natural marble(sipeol, bianko) of art wall of on-site interior finishing system and wall of elevator hall has occurred. The bottom of the art wall of stone junction tile has defects as cracks. To solve these problems, our research team developed eco-friendly complex stone panel(stone 4T + cement board 6T) and high-frequency hot-melt construction method that can construct in winter.

  • PDF