• Title/Summary/Keyword: Concentration efficiency

Search Result 4,544, Processing Time 0.034 seconds

A Study on the Recycling Method of Vehicle Mat Residual Product (자동차 내장매트 부산물의 재활용방안에 관한 연구)

  • Jang, Seong-Ho;Park, Gil-Pyeong;Park, Jin-Sik
    • Journal of Environmental Science International
    • /
    • v.15 no.12
    • /
    • pp.1199-1203
    • /
    • 2006
  • This paper analyzes the separation efficiency of vehicles mat residual product, and caloric value, element analysis and heavy metal of separated PE & PVC mat residual product. A results of separation efficiency, fiber fraction of PE & PVC mat residual product was analyzed 71.9% and 18.6%, respectively. Caloric value of PE & PVC mat residual product was analyzed 3,894kca1/kg and 10,203kca1/kg, respectively. A results of element analysis, main component of PVC mat were carbon(33.2%) and oxygen(21.0%), and main component of PE mat fiber were carbon(75.4), hydrogen(11.3%) and oxygen(9.1%). Lead and cadmium concentration of PVC powder was detected 98.9mg/kg and 19.8mg/kg, but Lead and cadmium concentration of fiber was detected 15.7mg/kg and 6.1mg/kg.

Determination of Boron Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation

  • Park, Chang-J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1541-1544
    • /
    • 2002
  • The concentration of B in steels is important due to its influence on mechanical properties of steel such as hardenability, hot workability, and creep resistance. An analytical method has been developed to determine B in steel samples by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). National Institute of Standard and Technology Standard Reference Material (NIST SRM) 348a was analyzed to validate the analytical method. The steel sample was digested in a centrifuge bottle with addition of aqua regia and $^{10}B$ spike isotope. Sample pH was then adjusted to higher than 10 to precipitate most matrix elements such as Fe, Cr, and Ni. After centrifugation, the supernatant solution was passed through a cation exchange column to enhance the matrix separation efficiency. B recovery efficiency was about 37%, while matrix removal efficiency was higher than 99.9% for major matrix elements. The isotope dilution method was used for quantification and the determined B concentration was in good agreement with the certified value.

A Study on the Preparation of Poly(vinyl alcohol) Polarizing Film (폴리비닐알코올 편광필름 제조에 관한 연구)

  • 김삼수;우화령;류원석
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.19-25
    • /
    • 2004
  • Both poly(vinyl alcohol)$(PVA)-I_2$ and PVA-dye polarizing film were prepared using PVA with number-average degree of polymerization of 1,700, 2,300, 2,600. The optical property of used dye in this study closed to the that of iodine. The PVA-dye polarizing film was prepared through the dyeing process. In comparison of the result of the measurement of the heat and humidity resistance of two types polarizing films, it of PVA-dye polarizing film was higher than that of a conventional $PVA-I_2$polarizing film. The transmittance and the polarization efficiency of PVA-dye polarizing film was significantly influenced by dye concentration, dipping time, salt concentration, and temperature of dye bath. The PVA-dye polarizing film exhibited a high polarization efficiency of 99.3% and a good transmittance of 42.4%.

A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate (황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거)

  • 서정민
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

Optimization of Programmed Suppression in a Cell-Free Protein Synthesis System with Unnatural Amino Acid S-(2-Nitrobenzyl)cysteine

  • HYUN JOO;KANG, TAEK JIN;HUI KYOUNG SONG;JIN HO AHN;CHA YONG CHOI
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.3
    • /
    • pp.344-347
    • /
    • 2003
  • Unnatural amino acid S-(2-nitrobenzyl)cysteine was incorporated into human erythropoietin by using a programmed suppression of nonsense codon in a cell-free protein synthesis system. Several controlling factors affecting the operational efficiency of the suppression were investigated and optimized. The amount of suppressor tRNA and the concentration of $Mg^2+$ were crucial not only for the efficiency but also for the control of the exact suppression. In addition, some general optimization factor are reported in order to improve the efficiency in an unnatural amino acid mutagenesis.

Study on Mixing Enhancement of a Y-channel Micromixer with Obstacles (Y-채널 마이크로믹서의 혼합 증대에 관한 연구)

  • Choi Jangwook;Choi Hyung-il;Lee Dong-ho;Lee Dohyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.12 s.243
    • /
    • pp.1369-1376
    • /
    • 2005
  • Effective mixing gives strong advantageous impact on microfluidic applications since mixing is in general very slow process motivated by molecular diffusion transport only on the micro-scale. In this work, the mixing characteristics are analyzed in a Y-channel micromixer with obstacles. For the through analysis, our laboratory in-house unstructured grid CFD code is validated through solving a concentration transport in a uniform microchannel. The solutions well correspond to both exact solutions and those from MemCFD. Mixing in a Y-channel micromixer with obstacles is numerically investigated by the in-house code to search the optimal radius and layout of obstacles. From the simulations, the mixing efficiency appears to be proportional to the magnitude of the formation of lateral velocity component. It is also shown that the asymmetric layout and radius enlargement of obstacles greatly improves mixing efficiency.

Study on Corrosion Inhibition Efficiency of Stem Alkaloid Extract of Different Varieties of Holy Basil on Aluminium in HCl Solution

  • Kumpawat, Nutan;Chaturvedi, Alok;Upadhyay, R.K.
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.4
    • /
    • pp.401-405
    • /
    • 2012
  • Corrosion inhibition efficiencies of holy basil on Al in HCl solution were studied by weight loss and thermometric methods in presence and in absence of stem extract of three different varieties of holy basil viz. ocimum basilicum ($E_B$), ocimum canum ($E_C$) and ocimum sanctum ($E_S$). Inhibition efficiency increases with the increasing concentration of stem extract and decreases with increases in acid strength. Results show that all varieties under study are good corrosion inhibitors, among which, $E_B$ is most effective. Maximum inhibition efficiency was found 97.09% in 0.5N HCl solution with 0.6% stem extract. The Langmuir adsorption isotherm indicates that surface coverage also increases with increasing in the concentration of extract of stem in HCl solution.

Performance Characteristics of Direct Methanol Fuel Cell with Methanol Concentration (메탄올 농도에 따른 직접 메탄올 연료전지의 성능 해석)

  • Cho, Chang-Hwan;Kim, Yong-Chan;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.197-204
    • /
    • 2008
  • DMFC(Direct Methanol Fuel Cell) is one of promising candidates for power sources of small mobile IT devices like notebook, cell phone, and so on. Efficient operation of fuel cell system is very important for long-sustained power supply because of limited fuel tank size. It is necessary to investigate operation characteristics of fuel cell stack for optimal control of DMFC system. The generated voltage was modeled according to various operating condition; methanol concentration, stack temperature, and load current. It is inevitable for methanol solution at anode to cross over to cathode through MEA(membrane electrode assembly), which reduces the system efficiency and increases fuel consumption. In this study, optimal operation conditions are proposed by analyzing stack performance model, cross-over phenomenon, and system efficiency.

The Development and Performance Test of a Small Wood Boiler (소형 화목보일러의 개발 및 성능시험)

  • Kim, Sa-Ryang;Lee, Jong-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.491-497
    • /
    • 2002
  • In the present study, a new wood boiler was developed through the performance test. The efficiency of the boiler was obtained up to about 63.7%, which is 67% higher than that of conventional wood boiler, about 38.2%. The structure of the new boiler is more complicated than the conventional boiler. The passage of combustion gas is sufficiently long to exchange heat well with heating water. Therefore, the obtained efficiency is so high, and the temperature of exhaust gas was lower than 200$^{\circ}C$, which is as low as that of light oil boiler. The composition of exhaust gas was measured, and the CO gas concentration was obtained more than 3000 ppm. So, it seems that more study is needed to lower the concentration of CO gas.

고정화 질화세균을 이용한 저농도 암모니아의 고도처리 (II) 초기 암모니아 농도, 온도 그리고 pH의 영향

  • Lee, Jeong-Hun;Kim, Byeong-Jin;Lee, Min-Su;Na, In-Geol;Seo, Geun-Hak
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.346-348
    • /
    • 2002
  • This study estimated the effect of influent TAN concentration. temperature and pH in the airlift bioreactor(aeration rate; 1.5 vvm, HRT 0.35hr) using immobilized nitrifiers by PVA. At the effect of influent TAN concentration, removal rate was increased with increasing it and removal efficiency maintained 93${\pm}$2%. The optimum temperature for nitrification was $30^{\circ}C$ and at this point. removal efficiency was 95.5${\pm}$1.5%. It was effective to nitrify at $10^{\circ}C$ of low temperature. In the pH range from 7 to 9 in the bioreactor. removal rate and removal efficiency was 310${\pm}$10 $g/m^3$ day and 94${\pm}$3%.

  • PDF