DOI QR코드

DOI QR Code

The Development and Performance Test of a Small Wood Boiler

소형 화목보일러의 개발 및 성능시험

  • Published : 2002.03.01

Abstract

In the present study, a new wood boiler was developed through the performance test. The efficiency of the boiler was obtained up to about 63.7%, which is 67% higher than that of conventional wood boiler, about 38.2%. The structure of the new boiler is more complicated than the conventional boiler. The passage of combustion gas is sufficiently long to exchange heat well with heating water. Therefore, the obtained efficiency is so high, and the temperature of exhaust gas was lower than 200$^{\circ}C$, which is as low as that of light oil boiler. The composition of exhaust gas was measured, and the CO gas concentration was obtained more than 3000 ppm. So, it seems that more study is needed to lower the concentration of CO gas.

Keywords

References

  1. 소각로에서 공해 물질의 생성과 제어, 1993, 한국과학기술원 기계공학과 저공해소각로 종합시스템연구팀
  2. 주승기, 1998, 페타이어 소각로 최적화, 서울대학교, 대학산업기술지원단 연구보고서
  3. 이규석, 이금배, 전용두, 2001, '에너지 절약형 자원 재활용 보일러 개발연구,' 2001 하계학술발표회 논문집, 대한설비공학회, pp. 466-470
  4. 보일러 및 가열로의 열선계, 1996, 제3차 산학협동 공개강좌, 한국과학기술원, pp. 36-47
  5. 정태용, 1998, 열동력학, 문운당, pp.59-94
  6. 김광렬, 노수영, 김영주, 1999, 최신 연소공학, 동화기연, pp. 15-35
  7. 김호영, 전철균, 황호영, 1998, '스토커형 소각로의 연소특성 및 연소 모델에 관한 연구,' 대한기계학회논문집B권, 제22권 제5호, pp. 627-639
  8. 장홍훈, 정구봉, 2000, 열관리 기사, 크라운출판사, pp. 77-105
  9. 환경관계법규 : 판례, 질의회답, 고시 (I) 대기편, 1999, 홍문관, pp. 150-154
  10. 대기환경연구회, 1995, 대기오염개론, 도서출판 동화기연 pp. 51-57

Cited by

  1. An Experimental Study on the Fire Risk of a Firewood Boiler vol.29, pp.3, 2015, https://doi.org/10.7731/KIFSE.2015.29.3.037