• 제목/요약/키워드: Concentration Load

검색결과 1,033건 처리시간 0.028초

축산농가에서 배출되는 비점오염 물질이 소규모 유역에 미치는 영향 (Effect of NPS Loadings from Livestock on Small Watersheds)

  • 이수인;신민환;전제홍;박병기;이지민;원철희;최중대
    • 한국농공학회논문집
    • /
    • 제57권2호
    • /
    • pp.27-36
    • /
    • 2015
  • The objective of this paper was to quantitatively analyze the effect of concentrated animal feeding operations (CAFO) NPS pollution on a small watershed water quality. Monitoring was conducted from March to October, 2013. Monthly flow rate and selected water quality at each monitoring site were measured during dry days. Rainy day monitoring also was conducted. Modeling was conducted to evaluate the effect of CAFO NPS pollution on the water quality at the watershed outlet. The highest and mean concentration of selected water quality indices during rainy days were higher than those in dry days in general. The highest TN concentration measured at the CAFP pollution discharge point was 237.831 mg/L. The results revealed that the CAFO NPS pollution sources could be equally blamed for the water quality degradation of the stream. However, the effect of the NPS pollution from CAFOs seemed not to be very influential to the watershed water quality at the outlet. SWAT modeling revealed that the TN load was reduced by 18.95 %, 23.39 % and 30.53 % at the watershed outlet if the TN load at the CAFO NPS pollution discharge point reduced by 20 %, 40 % and 60 %, respectively. It was thought that the natural attenuation processes played an important role. The modeling was based only on the assumption of the load reduction and not verified by the monitored data. Therefore, it was suggested that a long term monitoring studies for the evaluation of the impact of CAFO NPS pollution on the watershed water quality be conducted.

경안천지역의 도로 및 주차장에 대한 강우유출수의 특성분석과 원단위 산정 (Characterization of Stormwater Pollutants and Estimation of Unit Loads for Road and Parking Lot in Gyeongan Stream Watershed)

  • 고성훈;쉬라즈 아메드 메몬;이창희
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.689-696
    • /
    • 2009
  • Unit load approach has been used to estimate the non-point pollutant load in Total Water Pollution Load Management System (TWPLMS). In this study, locally applicable unit loads for road and parking lot were developed based on the measurements of 9 rainfall events from 2007 to 2008 in Yongin city of Gyeongan stream watershed. Observations showed that stormwater runoff began at low precipitation (>1 mm) and peak pollutant concentration occurred at the beginning of the runoff because of impervious nature of the sites. Averaged event mean concentrations (EMCs) of road (parking lot) were estimated as COD 105.36(62.69) mg/L, BOD 15.94(13.20) mg/L, TSS 183.45(66.52) mg/L, T-N 4.63(3.28) mg/L, T-P 0.45(0.39) mg/L. Higher EMCs at the road than parking lot may reflect heavier traffic. Unit loads Estimated from the EMCs and 10 year average rainfall data were COD $331.17kg/km^2{\cdot}day$, BOD $50.20kg/km^2{\cdot}day$, TSS $580.13kg/km^2{\cdot}day$, T-N $14.68kg/km^2{\cdot}day$, T-P $1.43kg/km^2{\cdot}day$ in the road and COD $186.59kg/km^2{\cdot}day$, BOD $39.22kg/km^2{\cdot}day$, TSS $199.15kg/km^2{\cdot}day$, T-N $9.70kg/km^2{\cdot}day$, T-P $1.16kg/km^2{\cdot}day$ in the parking lot. The estimated unit loads are not so comparable to the ones listed in TWPLMS technical guideline and published data that locally developed unit loads should be used to estimate non-point pollutant loads.

DESIGN OF A LOAD FOLLOWING CONTROLLER FOR APR+ NUCLEAR PLANTS

  • Lee, Sim-Won;Kim, Jae-Hwan;Na, Man-Gyun;Kim, Dong-Su;Yu, Keuk-Jong;Kim, Han-Gon
    • Nuclear Engineering and Technology
    • /
    • 제44권4호
    • /
    • pp.369-378
    • /
    • 2012
  • A load-following operation in APR+ nuclear plants is necessary to reduce the need to adjust the boric acid concentration and to efficiently control the control rods for flexible operation. In particular, a disproportion in the axial flux distribution, which is normally caused by a load-following operation in a reactor core, causes xenon oscillation because the absorption cross-section of xenon is extremely large and its effects in a reactor are delayed by the iodine precursor. A model predictive control (MPC) method was used to design an automatic load-following controller for the integrated thermal power level and axial shape index (ASI) control for APR+ nuclear plants. Some tracking controllers employ the current tracking command only. On the other hand, the MPC can achieve better tracking performance because it considers future commands in addition to the current tracking command. The basic concept of the MPC is to solve an optimization problem for generating finite future control inputs at the current time and to implement as the current control input only the first control input among the solutions of the finite time steps. At the next time step, the procedure to solve the optimization problem is then repeated. The support vector regression (SVR) model that is used widely for function approximation problems is used to predict the future outputs based on previous inputs and outputs. In addition, a genetic algorithm is employed to minimize the objective function of a MPC control algorithm with multiple constraints. The power level and ASI are controlled by regulating the control banks and part-strength control banks together with an automatic adjustment of the boric acid concentration. The 3-dimensional MASTER code, which models APR+ nuclear plants, is interfaced to the proposed controller to confirm the performance of the controlling reactor power level and ASI. Numerical simulations showed that the proposed controller exhibits very fast tracking responses.

HMIPv6에서의 MAP의 부하 제어 및 경로 최적화 (MAP Load Control and Route Optimization in HMIPv6)

  • 남성현;이경근
    • 대한전자공학회논문지TC
    • /
    • 제45권12호
    • /
    • pp.120-127
    • /
    • 2008
  • HMIPv6는 효율적인 핸드오버를 제공하고 시그널링 오버헤드를 줄이기 위한 기술로 주목받고 있다. HMIPv6는 이러한 시그널링 오버헤드와 지역적 이동성 관리를 위해 MAP(Mobility Anchor Point)를 도입한다. MAP는 빈번한 핸드오버가 발생하는 HMIPv6 네트워크 환경에서 효율적인 이동성 관리를 이룬다. 그러나 HMIPv6는 특정한 MAP로의 부하집중과 같은 네트워크 안에 존재하는 MN(Mobile Node)와 CN(Correspondent Node)사이의 불필요한 지연을 발생시킨다. 또한 모든 패킷은 MAP를 경유하여 전송되기 때문에 MAP는 HMIPv6 네트워크에서의 경로 최적화를 방해한다. 본 논문은 HMIPv6 네트워크에서 MAP의 부하에 따라 경로를 최적화하는 방법을 제안한다. 제안하는 방법은 MAP 도메인 안에서 최적의 서비스를 제공하기 위한 임계값을 설정하고 MAP에 연결된 이동노드의 수가 임계값을 넘어서는 경우에 MAP를 거치지 않고 AR(Access Router)로 직접 전송하도록 한다. 이에 따라 제안하는 방법은 시그널링 비용을 줄일 뿐만 아니라 특정한 MAP의 부하집중을 완화시킨다.

호흡률 측정기를 이용한 파일럿 스케일 염색폐수처리 장치에서의 생물학적 활성 측정 (Measurement of Biological Activity in Pilot Scale Dyeing Wastewater Process by Using Respirometer)

  • 전현희;최광근;윤인준;이진원
    • KSBB Journal
    • /
    • 제19권5호
    • /
    • pp.390-393
    • /
    • 2004
  • Oxygen uptake rate (OUR) was used as an indicator of microbial activity. In this study OUR at dyeing wastewater in the pilot plant was monitored to examine biological activity. Correlation between inlet COD concentration and maximum OUR showed that maximum OUR was proportional to inlet COD concentration. Changes in the OUR values reflected the changing waste load in the reactor. Consequently, OUR can be used to estimate biological activity of inlet COD concentration. This study showed that biodegradable COD at dyeing wastewater could be calculated from OUR and yield coefficient. Non-biodegradable COD was able to be calculated from a difference between initial COD concentration and biodegradable COD.

양무한평판의 두 원공비렬이 응력집중에 미치는 영향 (The Effect of Two Circular Holes Arrangement on the Stress Concentration Factor in a Semi-infinite Plate)

  • 오세욱;박영철;김준영
    • 한국해양공학회지
    • /
    • 제4권1호
    • /
    • pp.110-119
    • /
    • 1990
  • This study is concerned about the stress concentration factor measurement by photoelastic method, for the case of two circular holes arrangement in 3mm semi-infinite plate under tensile load, the ratio of those two circular holes diameter, the ratio of distance apart from circular holes to breadth and the two holes arrangement angle with loading direction were varied. Besides, the measured stress concentration by photoelastic method around one circular hole was compared with that by strain-gage method.

  • PDF

이종재 접합부에서의 응력집중현상에 관한 연구 (A Study on the Stress Concentration Phenomenon of a Dissimilar Joints)

  • 조상명;김영식
    • Journal of Welding and Joining
    • /
    • 제10권1호
    • /
    • pp.35-42
    • /
    • 1992
  • In this study, the stress concentration phenomenon for the dissimilar joints(ceramic-metal) bonded by thermal treating using a soft-insert metal(copper) was investigated with the aid of FEM(finite element method) under the load condition of uniform tension. The analysis was carried out by the supposing that stress states are plane stress or plane strain and elastic or elastic-plastic. And the Von Mises yield criterion and the incremental theory as plastic flow were adopted in this analysis. As the summarized results obtained, the stress concentration phenomenon was severer as the soft insert metal was thicker, in plane strain than in plane stress and in elastic-plastic state than in elastic state. Furthermore, the inducing mechanism of stress concentration was well expressed by the constraint forces(Fc) generated between the soft and the hard material.

  • PDF

쇄석다짐말뚝의 응력분담비에 관한 현장실험 연구 (A Field Test Study on stress concentration ratio of Crushed-Stone Column Pile)

  • 이민희;임종철;황근배;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.525-532
    • /
    • 2004
  • Among soft ground treatment methods with granular soil used in domestic, the sand compaction pile method has been utilized greatly, but, as a result of exhaustion of sand and increase of unit cost, a necessity of an alternative method is suggested. In this study, the static load tests for crushed-stone compaction piles which were constructed on test field were performed. Based on test results, stress concentration ratios between the crushed-stone compaction pile and the soft ground were investigated and estimated. The stress concentration ratio was the range of 1.7 to 3.0 and the higher it was the more replacement rate was increased.

  • PDF

構造的 不連續에 기인하는 圓筒構造物의 應力集中現象에 관한 有限要素法에 의한 硏究 (A Study on Stress Concentration Phenomena in Cylindrical Structures due to Stractural Incontinuty by Finite Element Method)

  • 김두만;정세헌
    • 한국안전학회지
    • /
    • 제3권2호
    • /
    • pp.25-34
    • /
    • 1988
  • The stress concentration phenomena due to the structural incontinuty are studied by finite element method. In this study, a circular cylinder is treated. Under the axial load, the membrance action is dominate and the 24 D.O.F. cylindrical membrane finite element is used. The assembly of this element can successfully represent the original structure geometrically. The internal displacement function is such organized that the inter element compatibility condition is fully satisfied. In this study, the stress concentration factors due to the presence of a hole on the cylinder wall are obtained, and the factors versus the location of the hole is computed and plotted. It is found that the hole effect on the stress concentration disappears beyond the neighboring region of the hole size form the edge of the hole. Those results are useful for practical design in determining the region where the re-inforcing is necessary.

  • PDF

4행정 중속 디젤기관의 스모크리스 시동 (Smokeless Starting for 4 Cycle Medium Speed Diesel Engine)

  • 정석호
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.11-16
    • /
    • 2014
  • Although smoke emitted from ships is not included in IMO(International Maritime Organiztion) regulation yet, it is one of the substance what is polluting mainly the air. Especially, its concentration is very high when an engine is started and a load is rapidly changed. This is caused by unburned fuel what is injected more than necessary quantity after combustion period. It is possible to decrease smoke concentration emitted at starting engine by controlling fuel injection quantity, but it is concerned that time to rated speed must be spent. Then a governor what can reduce the smoke concentration without a loss of time to rated speed is needed. We adopted a electro-hydraulic governor what can control dual fuel start limit function and achieved very low level of smoke concentration without greater the loss of time to rated speed.