• 제목/요약/키워드: Concentration Efficiency

검색결과 4,539건 처리시간 0.04초

C545T가 첨가된 OLED 소자의 발광특성 (The Luminescent Characteristics of C545T Doped OLED Devices)

  • 주성후;양재웅
    • 한국표면공학회지
    • /
    • 제40권2호
    • /
    • pp.77-81
    • /
    • 2007
  • To investigate the characteristics of green light-emitting OLED device, C545T material with $Alq_3$ was doped in the OLED device of $ITO(1500)/2-TNATA(400{\AA})/NPB(80{\AA})/Alq_3:C545T(160{\AA})/Alq_3(240{\AA})/LiF(3{\AA})/Al(2400{\AA})$ structure, which was used as a activator at the respective concentration of 0.5 vol.%, 1 vol.%, 2 vol.% and 3 vol.%. It was observed from the experiments that the device efficiency firstly increased with the increase of C545T concentration and the maximum efficiency of 10.9 cd/A and 4.28 lm/W was obtained at C545T concentration of 1 vol.%, and then the device efficiency decreased as the C545T activator concentration increased above 2 vol.% contents, while the longest lifetime of over 750 hours was obtained at C545T concentration of 1 vol.%.

이동 전극형 전기집진기의 집진특성에 관한 연구 - II. 펄스 하전 파형 및 분진농도의 영향 - (A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - II. Effect of Wave Form of Pulse Energization and Dust Concentration -)

  • 김용진;하병길;정상현;홍원석;유주식
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.908-913
    • /
    • 2004
  • This study investigates the effect of the wave form of pulse energization and dust concentration on the collection characteristics of a moving electrode electrostatic precipitator (MEEP). Under the same specific corona power, the collection efficiency of the MEEP for the lower dust concentration ($2g/m^3$) becomes higher than that for the higher concentration ($10g/m^3$). Both the collection efficiency and specific corona power increase with increasing pulse period for the same value of applied voltage. The collection efficiency of MEEP is higher than that of the conventional fixed plate electrode electrostatic precipitator.

저농도 하수 유입 Membrane-BNR공정내 고정상담체 호기조에서의 SND (SND in the Fixed Media Tank of Membrane-BNR Process Treating Low C/N Wastewater)

  • 정용철;이정열;민경석
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.328-332
    • /
    • 2008
  • This research was about T-N removal efficiency of oxic reactor in which fixed media submerged from Membrane BNR(An+Ax+Ox) process. This experiment was implemented by using fixed media and changing DO concentration in the oxic reactor. Nitrification efficiencies of all modes were more than 98%. When no media was in the oxic reactor, T-N removal efficiency was only 47.4%, while it were shown from 60.3% to 67.4% with packed media, which indicated improved efficiency of 27~42%. The removal efficiencies of TCOD and BOD were more than 89%, 98% respectively, which could satisfy the guideline of advanced sewage reclamation by Department of Environment. When DO concentration in the packed oxic-media tank was 0.5~1.0 mg/L, T-N removal efficiency was low, which resulted from insufficient nitrification in the oxic reactor. Therefore, DO concentration of bulk solution needs to be kept more than 1.0 mg/L to induce higher nitrification efficiency in the reactor in which media was submerged. Also, the selection of DO concentration is important to prevent media from being clogged.

해수활어수조의 포말분리시 단백질 농도의 영향 (Effect of Protein Concentration on Foam Separation in a Seawater Aquarium)

  • 서근학;신정식;이창근;이석희;천재기;조재윤
    • 한국수산과학회지
    • /
    • 제37권1호
    • /
    • pp.18-23
    • /
    • 2004
  • Effect of initial protein concentration on the protein removal rate was assessed for seawater aquarium using a foam separator. Protein removal rate was increased and removal efficiency was decreased with the increase of initial protein concentration. Enrichment ratio was decreased and foam generation rate was increased with the increase of initial protein concentration. Total suspended solids (TSS) removal rate was increased with the increase of initial protein concentration, and TSS removal efficiency was decreased with the increase of initial protein concentration. Turbidity removal rate and removal efficiency were increased with the increase of initial protein concentration.

금속 Ni 분말을 용해하여 제조된 용액에서 Ni 농도 변화가 전기도금 된 Ni 필름 특성에 미치는 영향 (Influence of Change of Ni Concentration in Baths Fabricated by Dissolving Metal Ni Powders on Properties of Electrodeposited Ni Film)

  • 윤필근;박덕용
    • 한국표면공학회지
    • /
    • 제52권2호
    • /
    • pp.78-83
    • /
    • 2019
  • Chloride baths for electrodeposited Ni thin films were fabricated by dissolving metal Ni powders with the mixed solution consisting of HCl and de-ionized water. Current efficiency, residual stress, surface morphology and microstructure of Ni films with the change of metal ion ($Ni^{2+}$) concentrations in the plating solution were studied. Current efficiency was measured to be more than 90% with increasing $Ni^{2+}$ concentrations in the plating solution. Residual stress of Ni thin film was increased from about 400 to 780 MPa with increasing $Ni^{2+}$ concentration from 0.2 to 0.5 M. It is gradually decreased to 650 MPa at 0.9 M $Ni^{2+}$ concentration. Smooth surface morphologies were observed over 0.3 M $Ni^{2+}$ concentration, but nodule surface morphology at 0.2 M. Ni films consist of FCC(111), FCC(200), FCC(220) and FCC(311) peaks in XRD patterns. Preferred orientation of FCC(111) was observed and its intensity was slightly decreased with increasing $Ni^{2+}$ concentration. The average grain size was slightly increased at 0.3 M $Ni^{2+}$ concentration and then slightly decreased with increasing $Ni^{2+}$ concentration.

복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과 (Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol)

  • 김기연;김치년;김윤신;노영만;이철민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

저녹스 버너 설치 시설의 질소산화물 저감 효율 산정 방법 (The Methods Calculating the Reduction Efficiency of Nitrogen Oxide for the Facilities Including the Low NOx Burners)

  • 이기용
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.295-296
    • /
    • 2015
  • We presented the methods calculating the reduction efficiency of nitrogen oxide for the low $NO_x$ burner as the pollution prevention facilities. The standard $NO_x$ concentration was used on the emission factor of LNG, $3.7g/m^3$. The $NO_x$ reduction efficiency based on the $NO_x$ concentration was presented and the relationships between the $NO_x$ concentration and the emission factor or the specific heat emission factor were derived. These results could be accurately reflected on calculating the amount of the nitrogen oxide emissions. In addition, according to the arrangement of the low $NO_x$ burners the methods of applying their $NO_x$ reduction efficiency were proposed. The $NO_x$ reduction efficiency for the facilities consisting of the low $NO_x$ burners and the non-low $NO_x$ burners could be estimated with information about the reduction efficiency of each low $NO_x$ burners, the fuel consumption rate, and the heating value of fuel.

  • PDF

기수지역 선박평형수의 염소 생성 효율에 미치는 전기화학 처리의 영향 (Effect of Electrochemical Treatment on the Chlorine Generation Efficiency of Ballast Water in the Brackish Zone)

  • 최용선;이유기
    • 한국재료학회지
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2019
  • Indirect oxidation using chlorine species oxidizing agents is often effective in wastewater treatment using an electrochemical oxidation process. When chlorine ions are contained in the wastewater, oxidizing agents of various chlorine species are produced during electrolysis. In a ballast water management system, it is also used to treat ballast water by electrolyzing seawater to produce a chlorine species oxidizer. However, ballast water in the brackish zone and some wastewater has a low chlorine ion concentration. Therefore, it is necessary to study the chlorine generation current efficiency at various chlorine concentration conditions. In this study, the chlorine generating current efficiency of a boron-doped diamond(BDD) electrode and insoluble electrodes are compared with various chloride ion concentrations. The results of this study show that the current efficiency of the BDD electrode is better than that of the insoluble electrodes. The chlorine generation current efficiency is better in the order of BDD, MMO(mixed metal oxide), $Ti/RuO_2$, and $Ti/IrO_2$ electrodes. In particular, when the concentration of sodium chloride is 10 g/L or less, the current efficiency of the BDD electrode is excellent.

고효율 사이클론의 집진효율에 관한 연구 (A Study of High Particle Collection Efficiency of Cyclone)

  • 정진도;이상권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2227-2232
    • /
    • 2003
  • For a reasonable analysis of grade efficiency of cyclone separator, in-line measurements of particle size and particle concentration are needed. The purpose of this study is to define the correlation of measurement data and to measure grade efficiency and pressure drop. The authors adapted that the grade efficiency could be calculated directly from the counted particle numbers. The problem of collection efficiency calculation was different from counting rate of aerosol counters under the same conditions. It is important factor to use the rate of the particle counters to obtain reliable results. Therefore, the authors should use and calculate compensation factor considering sensitivity of aerosol counters, gas velocity and concentration affect higher 30% than originally measured grade efficiency. As the pressure drop and grade efficiency increase, as flow rate increase and then also pressure drop and grade efficiency increase.

  • PDF

Separation of Cd(II) from Aqueous Solutions by A New Consecutive Process Consisting of Supported Liquid Membrane and Electrodialysis

  • Altin, Sureyya;Altin, Ahmet
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권1호
    • /
    • pp.14-21
    • /
    • 2019
  • Supported liquid membrane process usually is used for recovering or enrichment of valuable metals in the industrial wastewater. But, even if the metals in the wastewater was separated with high chemical selectivity, it cannot be enough concentrated since separation performance of supported liquid membrane (SLM) process is limited by concentration gradient between feed solution and stripping solution. If metal concentration in the stripping solution to be enough low, transport of metal through membrane can be accomplishment constantly. Therefore, Electrodialysis (ED) has been placed after SLM process and the stripping solution of SLM was used as the feed solution for the ED process. Transport of ions in the solutions is successfully performed by ED process. Thus, the metal concentration in the stripping solution does not rise as to stop ion transport. Besides, valuable metals easily are concentrated by ED process for re-use. In this study, effects of operation parameters like initial Cd(II) concentration, HCl concentration in the feed solution of SLM and applied voltage are investigated on separation efficiency, flux and permeability of the both processes. As the feed solution concentration increased, all performance values has increased. When initial concentration of 100 mg/L is used, separation performances (SP) are 55% and 70%, for SLM and consecutive process, respectively. The best HCl concentration in the feed solution of SLM has determined as 2 M, in this conditions SP are 64% and 72%, for SLM and consecutive process, respectively. With increased of applied voltage on ED process, SP of the consecutive process has been raised from 72% to 83%. According to the obtained experimental data, consecutive process has better separation performance than SLM. When the separation performances of both processes were compared for the same operating conditions, it was determined higher the separation efficiency, permeability and flux values of the consecutive process, 8%, 9% and %10.6, respectively. Consequently, the use of the consecutive process increases the performance efficiency of both processes. The consecutive process studied has quite a good chemical separation efficiency, and enrichment capability. Moreover, this process requires few water and energy.