• Title/Summary/Keyword: Computer science and engineering

Search Result 16,209, Processing Time 0.046 seconds

Assessment of Composite Material Flaws on the Type III Cylinders for Compressed Natural Gas Vehicles (압축천연가스자동차용 Type III 용기의 복합재 결함 평가)

  • Kim, Young-Seob;Kim, Lae-Hyun;Yang, Dong-Ju
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.90-95
    • /
    • 2011
  • This study was conducted to judge requalification of cylinders by assessing composite flaws such as scratches, cuts, and gouges damaging on the composite of Type III cylinders for compressed natural gas vehicles. As a result of the flaw tolerance test, all specimens have satisfied with minimum requirement cycles according to damage levels based on ISO 19078 and cyclic performance for pressure showed beyond twenty thousands in damage level 1 and 2, and did eighteen thousands to twenty-one thousands in damage level 3. Eight of twelve specimens failed the test due to composite flaws and the rest of the cylinders failed regardless of flaws. The results of Finite Element Method followed by the computer simulation indicated that the stress of 79.5 MPa calculated on the flaw model of $1.25\;mm{\times}200\;mm$ and the stress of 66.6 MPa on the non-flaw model when the service pressure applied to inside of cylinder. The difference between the models is about 19.37%. We concluded that this difference influences fatigue life and this flaw model is a critical value affecting cyclic performance of cylinders.

Sound event detection model using self-training based on noisy student model (잡음 학생 모델 기반의 자가 학습을 활용한 음향 사건 검지)

  • Kim, Nam Kyun;Park, Chang-Soo;Kim, Hong Kook;Hur, Jin Ook;Lim, Jeong Eun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.5
    • /
    • pp.479-487
    • /
    • 2021
  • In this paper, we propose an Sound Event Detection (SED) model using self-training based on a noisy student model. The proposed SED model consists of two stages. In the first stage, a mean-teacher model based on an Residual Convolutional Recurrent Neural Network (RCRNN) is constructed to provide target labels regarding weakly labeled or unlabeled data. In the second stage, a self-training-based noisy student model is constructed by applying different noise types. That is, feature noises, such as time-frequency shift, mixup, SpecAugment, and dropout-based model noise are used here. In addition, a semi-supervised loss function is applied to train the noisy student model, which acts as label noise injection. The performance of the proposed SED model is evaluated on the validation set of the Detection and Classification of Acoustic Scenes and Events (DCASE) 2020 Challenge Task 4. The experiments show that the single model and ensemble model of the proposed SED based on the noisy student model improve F1-score by 4.6 % and 3.4 % compared to the top-ranked model in DCASE 2020 challenge Task 4, respectively.

Bio-marker Detector and Parkinson's disease diagnosis Approach based on Samples Balanced Genetic Algorithm and Extreme Learning Machine (균형 표본 유전 알고리즘과 극한 기계학습에 기반한 바이오표지자 검출기와 파킨슨 병 진단 접근법)

  • Sachnev, Vasily;Suresh, Sundaram;Choi, YongSoo
    • Journal of Digital Contents Society
    • /
    • v.17 no.6
    • /
    • pp.509-521
    • /
    • 2016
  • A novel Samples Balanced Genetic Algorithm combined with Extreme Learning Machine (SBGA-ELM) for Parkinson's Disease diagnosis and detecting bio-markers is presented in this paper. Proposed approach uses genes' expression data of 22,283 genes from open source ParkDB data base for accurate PD diagnosis and detecting bio-markers. Proposed SBGA-ELM includes two major steps: feature (genes) selection and classification. Feature selection procedure is based on proposed Samples Balanced Genetic Algorithm designed specifically for genes expression data from ParkDB. Proposed SBGA searches a robust subset of genes among 22,283 genes available in ParkDB for further analysis. In the "classification" step chosen set of genes is used to train an Extreme Learning Machine (ELM) classifier for an accurate PD diagnosis. Discovered robust subset of genes creates ELM classifier with stable generalization performance for PD diagnosis. In this research the robust subset of genes is also used to discover 24 bio-markers probably responsible for Parkinson's Disease. Discovered robust subset of genes was verified by using existing PD diagnosis approaches such as SVM and PBL-McRBFN. Both tested methods caused maximum generalization performance.

Video Transmission Technique based on Deep Neural Networks for Optimizing Image Quality and Transmission Efficiency (영상 품질 및 전송효율 최적화를 위한 심층신경망 기반 영상전송기법)

  • Lee, Jong Man;Kim, Ki Hun;Park, Hyun;Choi, Jeung Won;Kim, Kyung Woo;Bae, Sung Ho
    • Journal of Broadcast Engineering
    • /
    • v.25 no.4
    • /
    • pp.609-619
    • /
    • 2020
  • In accordance with a demand for high quality video streaming, it needs high data rate in limited bandwidth and more traffic congestion occurs. In particular, when providing real time video service, packet loss rate and bit error probability increase significantly. To solve these problems, a raptor code, which is one of FEC(Forward Error Correction) techniques, is pervasively used in the application layers as a method for improving real-time service quality. In this paper, we propose a method of determining image transmission parameters based on various deep neural networks to increase transmission efficiency at a similar level of image quality by using raptor codes. The proposed neural network uses the packet loss rate, video encoding rate and data rate as inputs, and outputs raptor FEC parameters and packet sizes. The results of the proposed method present that the throughput is 1.2% higher than that of the existing multimedia transmission technique by optimizing the transmission efficiency at a PSNR(Peak Signal-to-Noise Ratio) level similar to that of the existing technique.

Authentication and Key Management Techniques for Secure Communication in IP Camera (IoT 환경에서 IP카메라의 효율적 운용을 위한 키 관리 및 보안 설계 프로토콜)

  • Min, So-Yeon;Lee, Jae-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.602-608
    • /
    • 2020
  • Development of Internet technology and the spread of various smart devices provide a convenient computing environment for people, which is becoming common thanks to the Internet of Things (IoT). However, attacks by hackers have caused various problems, such as leaking personal information or violating privacy. In the IoT environment, various smart devices are connected, and network attacks that are used in the PC environment are occurring frequently in the IoT. In fact, security incidents such as conducting DDoS attacks by hacking IP cameras, leaking personal information, and monitoring unspecified numbers of personal files without consent are occurring. Although attacks in the existing Internet environment are PC-oriented, we can now confirm that smart devices such as IP cameras and tablets can be targets of network attacks. Through performance evaluation, the proposed protocol shows 11% more energy efficiency on servers than RSA, eight times greater energy efficiency on clients than Kerberos, and increased efficiency as the number of devices increases. In addition, it is possible to respond to a variety of security threats that might occur against the network. It is expected that efficient operations will be possible if the proposed protocol is applied to the IoT environment.

A Real-time H.264 to MPEG-2 Transcoding for Ship to Shore Communication (선박-육지간 통신을 위한 실시간 H.264 to MPEG-2 트랜스코딩)

  • Son, Nam-Rye;Jeong, Min-A;Lee, Seong-Ro
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.90-102
    • /
    • 2011
  • Recently, the grade of users using wireless communication services which transmits and re-transmits to the signal via the broadcasting satellite have a variety. However the ships not preparing of H.264 standard devices should not received the realtime data because the broadcasting stations have transmitted the compressed video data through the satellite communication. Therefore this paper proposes H.264 to MPEG-2 transcoding for the ships using MPEG-2 devices. Proposed method improves a speed and object quality in H.264 to MPEG-2 transcoding by analysis features of macroblock modes in H.264. In the Intra mode of P-frame, it proposes new method by computing coincidence proportion after comparing of Intra mode methods of H.264 and MPEG-2. In the Inter mode, it proposes a PMV(predictive motion vector) considering movement of motion vectors in H.264 decoder. we reuses a PMV directly as like the final MV in MPEG-2 encoder and refinements the MV after coincidence ratio comparing of variable motion vectors of H.264 and these of MPEG-2. The experimental results from proposed method show a considerable reduction in processing time, as much as 70% and 67% respectively, with a small objective quality reduction in PSNR.

Comparison of the Priority of Required Capabilities of the Warrior Platform by the Types of Military Unit through AHP Analysis (AHP 분석을 통한 부대 임무유형별 워리어플랫폼 요구능력 우선순위 비교)

  • Kim, Wukki;Shin, Kyuyong;Jo, Seongsik;Baek, Seungho;Kim, Yongchul
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.6
    • /
    • pp.262-269
    • /
    • 2021
  • The Ministry of National Defense is re-establishing the role of the Army in accordance with the defense reform and is promoting the Warrior Platform, a next-generation individual combat system. The Warrior Platform project is divided into three stages and is being promoted. In the first stage, the quality and performance of individual items are improved, in the second stage, items between system development are integrated, and in the third stage, the combat capability is maximized by developing an integrated unit weapon system. In this paper, detailed sub-items for the five essential required competencies (survival, lethality, mobility, sustainability, Communication) that are considered for building an effective warrior platform are presented. We also present a plan that can be used to prepare a specific master plan for the Army's Warrior Platform project by using Analytic Hierarchy Process(AHP) and selecting the priority of the five required capabilities and detailed sub-items for different unit types. As a result of analyzing the priorities of the four types of units with different mission types, we find that there are differences for each unit. These results are expected to be used as useful reference materials for setting the future direction for the development of warrior platform.

The Study on Control Algorithm of Elevator EDLC Emergency Power Converter (승강기 EDLC 비상전원 전력변환장치 제어 알고리즘 연구)

  • Lee, Sang-min;Kim, IL-Song;Kim, Nam
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.6
    • /
    • pp.709-718
    • /
    • 2017
  • The installation of the elevator ARD(Automatic Rescue Device) system has been forced into law in these days in order to safely rescue passengers during power failure. The configuration of the ARD system consists of energy storage device, power converter and control systems. The EDLC(Electric Double Layer Capacitor) are used as energy storage device for rapid charge/discharge purposes. The power conditioning system (PCS) consists of bi-directional converter, 3-phase converter and control system. The dead-beat control system is adopted for most systems however it requires complex mathematical calculations, the high performance microprocessors are mandatory and thus it can be a cause of high manufacturing cost. In this paper the new control method for average current mode control is presented for simple structure. The control algorithm is applied to the single phase system and then expands to three phase system to meet the sysem requirements. The mathematical modeling using average modeling method is presented and analysed by PSIM computer simulation to verifie the validity of the proposed control methods.

Study on the Nozzle Spacing in the Boom-Type Nozzle System (Boom-Type Nozzle System의 분두배치(噴頭配置)에 관(關)한 연구(硏究))

  • Seo, Jeoung Duk;Lee, Sang Woo
    • Korean Journal of Agricultural Science
    • /
    • v.8 no.2
    • /
    • pp.212-223
    • /
    • 1981
  • The proper nozzle spacings have been tried to determined the better evenness of distribution on the development of the boom type nozzle system with three nozzles made in Korea-disk type, cap type and bolt type. The operating pressure has been changed in 7 levels ($2kg/cm^2-8kg/cm^2$) and the operating height in 3 levels (30, 40, 50cm) to find characteristics of deposit pattern and the proper spacing of each nozzle was examined and computed. The results of this study were as follows; 1. The CU(%) of the deposit distribution was improved with the operating pressure of $5kg/cm^2$ or $6kg/cm^2$ in Nozzle A with 80% and Nozzle C with 83%, and $7kg/cm^2$in Nozzle B with 80% 2. The better deposit distribution was got ten at operating height 40cm with CU 86% in Nozzle A, and 50cm in both Nozzle B, C with 80% 3. The spray deposit distribution was getting of improvement with decrease of nozzle spacing, nevertheless about half diameter of the spraying circle was recommended in regard to the cost and the work performance. 4. Improvement of quality of nozzles tested in this research may be required not to be less than their CU 90% in the use as boom-type nozzle system.

  • PDF

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF