• Title/Summary/Keyword: Computer Software

Search Result 8,373, Processing Time 0.035 seconds

A Method for Measuring and Evaluating for Block-based Programming Code (블록기반 프로그래밍 코드의 수준 및 취약수준 측정방안)

  • Sohn, Wonsung
    • Journal of The Korean Association of Information Education
    • /
    • v.20 no.3
    • /
    • pp.293-302
    • /
    • 2016
  • It is the latest fashion of interesting with software education in public school environment and also consider as high priority issue of curriculum for college freshman with programming 101 courses. The block-based programming tool is used widely for the beginner and provides several positive features compare than text-based programming language tools. To measure quality of programming code elaborately which is based script language, it is need to very tough manual process. As a result the previously research related with evaluation of block-based script code has been focused very simple methods in which normalize the number of blocks used which is related with programming concept. In such cases in this, it is difficult to measure structural vulnerability of script code and implicit programming concept which does not expose. In this research, the framework is proposed which enable to measure and evaluate quality of code script of block-based programming tools and also provides method to find of vulnerability of script code. In this framework, the quality metrics is constructed to structuralize implicit programming concept and then developed the quality measure and vulnerability model of script to improve level of programming. Consequently, the proposed methods enable to check of level of programming and predict the heuristic target level.

Development and Effects of Intelligent CCTV Algorithm Creative Education Program Using Rich Picture Technique (리치픽처 기법을 적용한 지능형 CCTV 알고리즘 창의교육 프로그램 개발 및 효과)

  • Jung, Yu-Jin;Kim, Jin-Su;Park, Nam-Je
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.125-131
    • /
    • 2020
  • As technology advances, the importance of software education is increasing. Accordingly, interest in information subjects is increasing, but intending elementary learners to show algorithms only for specialized IT skills that could spoil the interest. In this paper for the elementary school students, through the four stages, 2015 revision curriculum analysis, creating of training program development operating plans, applying programs for the targeting students and analysis of results and evaluation, using Rich Picture technique which is various tools such as pictures and speech bubble symbols for the learners can express the intelligent CCTV algorithm freely and easily so they can understand fully about the algorithm of intelligent CCTV that uses artificial intelligence to extract faces from subjects. Suggest on this paper, the proposal of educational program can help the learner to grasp the principle of the algorithm by using the flowchart. As the result, Through the modification and development of the proposed program, we will conduct research on IT creative education that can be applied in various areas.

Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography (안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이)

  • Kim, Wang-Sik;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.163-173
    • /
    • 2005
  • The purpose of this study was to compare the asymmetric degree between maxillofacial hard and soft tissues in individuals with facial asymmetry. Computerized tomographies (CT) of 34 adults (17 male, 17 female) who had facial asymmetry were taken. The CT images were transmitted to personal computers and then reconstructed into three-dimensional (3D) images through the use of computer software. In order to evaluate the degree of facial asymmetry, 6 measurements were constructed as the hard tissue measurements while 6 counterpart measurements were taken as the soft tissue measurements. The means and standard deviations were obtained for each measurement using 3D measure, then t-test was used to investigate the differences between each hard tissue measurement and the corresponding soft tissue measurement All measurements used in the present study showed statistically significant differences between the hard and soft tissues. The degree of soft tissue asymmetry was smaller than that of corresponding hard tissue asymmetry in case of chin deviation, frontal ramal inclination difference, and frontal corpus inclination difference. On the other hand, the degree of soft tissue asymmetry was greater than that of underlying hard tissue asymmetry in the measurement of lip canting and lip cheilion height difference The present study suggests that asymmetric differences of hard and soft tissue is observed nu facial asymmetric subjects and thus soft tissue analysis is needed in addition to hard tissue analysis when making an evaluation of facial asymmetry.

Visual Touchless User Interface for Window Manipulation (윈도우 제어를 위한 시각적 비접촉 사용자 인터페이스)

  • Kim, Jin-Woo;Jung, Kyung-Boo;Jeong, Seung-Do;Choi, Byung-Uk
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.6
    • /
    • pp.471-478
    • /
    • 2009
  • Recently, researches for user interface are remarkably processed due to the explosive growth of 3-dimensional contents and applications, and the spread class of computer user. This paper proposes a novel method to manipulate windows efficiently using only the intuitive motion of hand. Previous methods have some drawbacks such as burden of expensive device, high complexity of gesture recognition, assistance of additional information using marker, and so on. To improve the defects, we propose a novel visual touchless interface. First, we detect hand region using hue channel in HSV color space to control window using hand. The distance transform method is applied to detect centroid of hand and curvature of hand contour is used to determine position of fingertips. Finally, by using the hand motion information, we recognize hand gesture as one of predefined seven motions. Recognized hand gesture is to be a command to control window. In the proposed method, user can manipulate windows with sense of depth in the real environment because the method adopts stereo camera. Intuitive manipulation is also available because the proposed method supports visual touch for the virtual object, which user want to manipulate, only using simple motions of hand. Finally, the efficiency of the proposed method is verified via an application based on our proposed interface.

A STUDY ON STRESS DISTRIBUTION IN IMZ IMPLANT WITH A PLASTIC OR A TITANIUM IME USING FINITE ELEMENT ANALYSIS (유한요소법을 이용한 IMZ임플란트의 플라스틱 및 티타늄 IME의 응력분포에 관한 연구)

  • Ha Chi-Yang;Choi Boo-Byung;Woo Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.625-642
    • /
    • 1993
  • Whether stress-absorbing elements are functional in an implant system has been an issue of interest in oral implantology. The unique feature of the IMZ implant system is the planned imitation of the stress-distributing function of the structural unit of the tooth, periodontium, and alveolar bone through the use of an intramobile element(IME). The purpose of this study was to compare the difference in the displacement and the stress distibutions of IMZ implant with a polyoxymethylene(POM) or a titanium IME under static load. Two dimensional finite element analysis(FEA) was applied for this study and two finite element models were created. PATRAN program(DPA Co.,USA), a software for FEA, and SUN-SPARC2GX(SUN Co., USA), a workstation computer, were used. $1Kg/mm^2$ of static load was loaded individually on each three point of crown of implant prosthesis ; central fossa(load 1), mesial cusp tip(load 2), distal cusp tip(load 3), The displacements of X- and Y-axis and total displacement were measured at mesial and distal cusp tips, mesial and distal points between crown and IME, and implant apex. The von Mises stress was measured at mesial and distal points between crown and IME, mesial and distal points between IME and TIE, mesial and distal alveolar crest, the mesial and distal midpoints of implant, and implant apex. The difference in resultant values were compared and evaluated statistically using paired t-test. The results were as follows : 1. Under the load 1, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except total and Y-axis displacement at implant apex. And the differences in stress distributions with POM and titanium were varied. 2. Under the load 2, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except X-axis displacement at distal cusp tip. And the differences in stress distributions were varied. 3. Under the load 3, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except Y-axis displacement at mesial cusp tip. And the differences in stress distributions were varied. 4. For the displacement, there was significant difference statistically only in total displacement (P<0.1), but was no significant difference in X- and Y-axis displacement(P>0.1). For the stress, there was no significant difference among the compared values.

  • PDF

Design Trend and Improvement Strategies of Contents Developed by Teachers -Focus on Prizewinner of the Research Competition on Educational Informatization- (교사 개발 콘텐츠의 설계 동향과 개선 방안 -교육정보화연구대회 입상작을 중심으로-)

  • Jo, Miheon
    • Journal of The Korean Association of Information Education
    • /
    • v.19 no.3
    • /
    • pp.311-322
    • /
    • 2015
  • This study analyzed the trend and problems in the design of contents developed by teachers, and suggested strategies for improvement. It analyzed the contents ranked as the first level in the Research Competition on Educational Informatization for the last 3 years. Concerning the 8 types of instructional activities and the 6 types of knowledge acquisition, most contents took limited types(i.e., the individual tutoring type, the concept learning type and the principle learning type). In addition, when the contents were evaluated according to the quality certification criteria for educational software, it was found that the quality level of the design was low in many criteria. When the content analysis was applied for the in-depth analysis of design characteristics, various problems were found in the areas such as evaluation, feedback and learning objectives. Also other common problems were found in the design areas such as level-based differentiated learning, interaction between students and contents, presentation of text and narration, utilization of information on a student, screen design, the content level appropriate for students. In relation to the problems found from the analysis, some strategies for improvement were suggested concerning the following topics: question selection and guidance for evaluation, content and types of feedback, statement of learning objectives, selection of content, interaction, and screen design.

A STUDY ON THE FACIAL ESTHETIC PREFERENCES AMONG KOREAN YOUTHS: ASSESSMENT OF PROFILE PREFERENCES (한국 젊은이의 안면미 선호경향에 관한 연구 : 얼굴의 측모평가를 중심으로)

  • Song, Sejin;Choi, Ik-chan
    • The korean journal of orthodontics
    • /
    • v.22 no.4 s.39
    • /
    • pp.881-920
    • /
    • 1992
  • This study was designed to assess profile preferences among Korean youths in the year 1992. Facial esthetics was evaluated by means of silhouette profiles, eliminating the influence of a number of aspects that may affect judgment when normal lateral photographs are used. The main points of preference to be clarified here are as follows. First, on facial convexity, Second, on nasion depth, Third, on mentolabial sulcus depth, Fourth, on the position of upper and lower lips, Fifth, on facial type according to Angle's classification of malocclusion, Sixth, on Song's tangents. The 54 subjects printed in questionnaire as black and white silhouettes were selected from 300 tracings from cephalometric radiographs of people whose age ranging from 11 to 20 years. Photographs of six female subjects were retouched by computer graphic software and printed in color and black/white photographs which were used for adaptation of eyes of participants in selecting profiles in silhouette. They constitute 2 questions. The 54 subjects were grouped as 22 questions, each of them composed of 6 subjects, according to the aspects to be clarified. Twenty four questions in total were asked to assess profile preferences. For the assessment, the profile line, the facial esthetic triangle, Song's tangents, and Angle's classification of malocclusion were introduced. The profile line is composed of 11 component points which are Trichion, Glabella, Nasion, Pronasale, Subnasale, Labrale superius, Stomion, Labrale inferius, Supramentale, Pogonion, and Gnathion. The facial esthetic triangle is composed of 3 tangents: A-tangent which is the tangent of dorsum of nose, B-tangent which is the line passing through Sn and Ls, and C-tangent which is drawn on the turning point of the curve which lies between mentolabial sulcus (Sm) and pogonion (Pg). Angle's classification has 3 types of malocclusion which are Class I, Class II, and Class III. Class II malocclusion is subdivided into Division 1 and Division 2. The participants of the survey were composed of 861 college students (448 male students, 413 female students) whose majors grouped as Fine Arts. Liberal Arts, and Natural Sciences, and whose mean age 21.8 years. The statistics program SPSS/PC + of SPSS Inc. was used to analyze answers of participants. Crosstabulation, Chi-square test, and Kendall test were done. The conclusions are as follows: First, Korean youths have a tendency to prefer the slightly convex face to the flat or concave face. Second, they prefer a moderately deep nasion. Third, they prefer a moderately deep mentolabial sulcus. Fourth, they prefer the position of lips which are near to Ricketts' E-line. The position of the upper lip which is slightly posterior to E-line is preferred. The upper lip which lies too far anterior or posterior to the lower lip is not perferred. Fifth, they prefer most, according to Angle's Classification of Malocclusion, Class I facial profile which has a slight inclination to Class II division 2. The order of preference is Class I, Class II division 2, Class III, and Class II division 1. Sixth, they prefer the type 2 and 3 of Song's tangents. The facial profile within which A-and B-tangent meet is preferred. The facial profile which has Cotangent that .meets with A-tangent slightly posterior to the crossing point of A-and B-tangent or that parallels with B-tangent is preferred.

  • PDF

The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT (임플랜트 전산화단층사진에서 하악의 위치와 gantry각의 변화가 임플랜트 매식로 평가에 미치는 영향에 관한 연구)

  • Lee Sul-Mi;An Chang-Hyeon;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.35-39
    • /
    • 2002
  • Purpose: The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program. Materials and Methods: A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0°, 15°, and 30°. Results: With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta perch a in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. Conclusion: ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  • PDF

Finite Element Stress Analysis on the Supporting Tissues depending upon the Position of Osseointegrated Implants Supporting Fixed Bridges (고정성 보철물을 지지하는 골유착성 임플란트의 위치에 따른 지지조직에서의 유한요소적 응력분석)

  • Yoon, Dong-Joo;Shin, Sang-Wan;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.1
    • /
    • pp.87-99
    • /
    • 1993
  • Many studies have been reported on the successful replacement of missing teeth with osseointegrated dental Implants. However, little research has been carried out on the bio-mechanical aspect of the stress on the surrounding bone of the free-standing type of dental implant prostheses. This experimental study was aimed to analyze the stress distribution pattern on the supporting tissues depending upon the position of osseointegrated implants supporting fixed bridges. In the cases of unilateral partially edentulous mandible (the 2nd premolar and the 1st and 2nd molars missing), two osseointegrated implants were placed at the 2nd premolar and 2nd molar sites (Model A) , the 1st and 2nd molar sites (Model B, Anterior cantilevered type), the 2nd premolar and 1st molar sites (Model C, Posterior cantilevered type). Chewing forces of dentate patients and denture wearer were applied vertically on the 2nd premolar, the 1st molar, and the 2nd molar of each model. A 3-Unit fixed partial denture was constructed at each model and cantilevered extension parts were involved in Model B and Model C. Two dimensional finite element analysis was undertaken. The commercial software (Super SAP) for IBM 16 bit personal computer was utilized. The results were as follows : 1. The magnitude of applied load influenced on the total value of stresses, but did not in-fluence on the pattern of stress distribution. 2. The magnitude of stress developed from the supporting tissues were in order of Model C,Model A,Model B. 3. High stresses were concentrated on the cervical and apical portion of the implant/bone interface. 4. A difference of the stress magnitude on the implant/bone interface between mesial and distal implant was most prominant in Model C and in order of Model A and Model B. 5. The stresses developed in Model A were evenly distributed throughout both implants. 6. The stresses concentrated on the cervical portion of cantilevered side were higher in the posterior cantilevered type than in the anterior cantilevered type.

  • PDF

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF