• Title/Summary/Keyword: Computed Correlation

Search Result 783, Processing Time 0.029 seconds

Assessment of Capsular Insertion Type and of Capsular Elongation in Patients with Anterior Shoulder Instability and It's Correlation with Surgical Outcome: A Quantitative Assessment with Computed Tomography Arthrography

  • Kim, Do Hoon;Kim, Do Yeon;Choi, Hye Yeon;Park, Ji Soon;Lee, Ye Hyun;Oh, Joo Han
    • Clinics in Shoulder and Elbow
    • /
    • 제19권3호
    • /
    • pp.155-162
    • /
    • 2016
  • Background: The study aimed to determine the type of capsular insertion and the extent of capsular elongation in anterior shoulder instability by quantitatively evaluating their computed tomography arthrographic (CTA) findings, and to investigate the correlation of these parameters with surgical outcomes. Methods: We retrospectively reviewed 71 patients who underwent CTA and arthroscopic capsulolabral reconstruction for anterior shoulder instability between April 2004 and August 2008. The control group comprised 72 patients diagnosed as isolated type II superior labrum anterior to posterior (SLAP) lesion during the period. Among the 143 patients, 71 were examined with follow-up CTA at an average 13.8 months after surgery. It was measured the capsular length and cross-sectional area at two distinct capsular regions: the 4 and 5 o'clock position of the capsule. Results: With regards to the incidence of the type of anterior capsular insertion, type I was more common in the control group, whereas type III more common than in the instability group. Anterior capsular length and cross-sectional area were significantly greater in the instability group than in the control group. Among patients of the instability group, the number of dislocations and the presence of anterior labroligamentous periosteal sleeve avulsion lesion were significantly associated with anterior capsular redundancy. Postoperatively, recurrence was found in 3 patients (4.2%) and their postoperative capsular length and cross-sectional area were greater than those of patients without recurrence. Conclusions: Capsular insertion type and capsular redundancy derived through CTA may serve as important parameters for the management of anterior shoulder instability.

영역 분할을 이용한 효율적인 음원 위치 추정 시스템 (Efficient Sound Source Localization System Using Angle Division)

  • 김용은;조수현;정진균
    • 대한전자공학회논문지SP
    • /
    • 제46권2호
    • /
    • pp.114-119
    • /
    • 2009
  • 서비스 로봇에서 사용되는 음원인식 시스템은 사람이 로봇을 향해 말할 때 화자의 위치를 추정한다. 로봇용 음원인식 알고리즘들 중에서 복수개의 마이크로폰에 소리가 도착하는 시간지연 정보를 이용하여 음원을 추정하는 방법이 널리 이용된다. 마이크로폰에 도달하는 지연시간 정보를 구하기 위해서 상관관계 함수가 사용된다. 상관관계 함수에서 최대 값의 위치를 각도로 변환할 때 코사인 역함수가 사용되며 코사인 역함수의 비선형적인 특성 때문에 음원의 위치에 따라 마이크로폰 쌍에서 추정하는 각도의 정확성이 다르게 된다. 본 논문에서는 음원의 위치에 따라 각도를 가장 잘 추정할 수 있는 각도 영역을 구분하여 정확하게 음원의 위치를 인식하는 방법을 제안한다. 또한 제안한 방법을 이용하면 각 마이크 쌍에서 60도 범위에 대해서만 각도를 계산하므로 기존의 180도에 대한 방법에 비하여 연산이 1/2로 줄어든다. 테스트 환경을 구축하여 제안한 영역 분할 위치 추정 알고리즘과 기존 알고리즘의 성능을 비교한 결과 제안한 알고리즘의 기존 알고리즘에 의한 평균오차의 31%에 불과함을 보인다.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

Correlation between pain and degenerative bony changes on cone-beam computed tomography images of temporomandibular joints

  • Bae, SunMee;Park, Moon-Soo;Han, Jin-Woo;Kim, Young-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.19.1-19.6
    • /
    • 2017
  • Background: The aim of this study was to assess correlation between pain and degenerative bony changes on cone-beam computed tomography (CBCT) images of temporomandibular joints (TMJs). Methods: Two hundred eighty-three temporomandibular joints with degenerative bony changes were evaluated. Pain intensity (numeric rating scale, NRS) and pain duration in patients with degenerative joint disease (DJD) were also analyzed. We classified condylar bony changes on CBCT into five types: osteophyte (Osp), erosion (Ero), flattening (Fla), subchondral sclerosis (Scl), and pseudocyst (Pse). Results: Degenerative bony changes were the most frequent in the age groups of 10~19, 20-29, and 50~59 years. The most frequent pain intensity was "none" (NRS 0, 34.6%) followed by "annoying" (NRS 3-5, 29.7%). The most frequent condylar bony change was Fla (219 joints, 77.4%) followed by Ero (169 joints, 59.7%). "Ero + Fla" was the most common combination of the bony changes (12.7%). The frequency of erosion was directly proportional to NRS, but the frequency of osteophyte was inversely proportional. The prevalence of Ero increased from onset until 2 years and gradually decreased thereafter. The prevalence of Osp, Ero, and Pse increased with age. Conclusions: Osp and Ero can be pain-related variables in degenerative joint disease (DJD) patients. "Six months to 2 years" may be a meaningful time point from the active, unstable phase to the stabilized late phase of DJD.

CT 검사에서 소아 환자의 정맥 카데터 삽입 통증에 대한 측정 도구 비교 (Comparison Study with Pain Assessment Tools of Pain Measurement in Children for Intravenous Catheter Placement in the Computed Tomography)

  • 권대철;장근조
    • 한국콘텐츠학회논문지
    • /
    • 제8권2호
    • /
    • pp.205-212
    • /
    • 2008
  • 소아 환자는 정맥주사의 통증에 대한 심리적인 거부감 및 두려움이 존재하고 있다. 정맥 카데터 주입시의 통증을 평가하기 위해 CT검사를 위해 내원한 소아 130명(나이 $8{\sim}13$)을 대상으로 하였다. 통증 분석은 시각적 상사 척도(visual analog scale, VAS), 수치 통증 강도 척도(numeric pain rating scale, NPRS), Wong-Baker의 안면 통증 단계 척도(Wong-Baker faces pain scale, WBFPS)를 개량한 3종류의 평가 도구를 이용하였다. 시각적 상사 척도, 수치 통증 강도 척도, Wong-Baker의 안면 통증 단계 척도 간의 양의 상관관계($r=0.70{\sim}0.92$)를 보이고 있다. 시각적 상사 척도/수치 통증 강도 척도에서 보다 좋은 일치도를 나타냈다.

Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

  • Yousefi, Faezeh;Shokri, Abbas;Zahedi, Foozie;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.429-438
    • /
    • 2021
  • Purpose: This study investigated the accuracy of laser-scanned models and 3-dimensional(3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and Methods: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches' length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. Results: There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements(>0.830) and between observers(>0.801). Conclusion: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.

Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment

  • Song, Chang-Ho;Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제52권3호
    • /
    • pp.283-288
    • /
    • 2022
  • Purpose: This study was conducted to measure the radiation exposure and image quality of various cone-beam computed tomography (CBCT) machines under common clinical conditions and to analyze the correlation between them. Materials and Methods: Seven CBCT machines used frequently in clinical practice were selected. Because each machine has various sizes of fields of view (FOVs), 1 large FOV and 1 small FOV were selected for each machine. Radiation exposure was measured using a dose-area product (DAP) meter. The quality of the CBCT images was analyzed using 8 image quality parameters obtained using a dental volume tomography phantom. For statistical analysis, regression analysis using a generalized linear model was used. Results: Polymethyl-methacrylate (PMMA) noise and modulation transfer function (MTF) 10% showed statistically significant correlations with DAP values, presenting positive and negative correlations, respectively (P<0.05). Image quality parameters other than PMMA noise and MTF 10% did not demonstrate statistically significant correlations with DAP values. Conclusion: As radiation exposure and image quality are not proportionally related in clinically used equipment, it is necessary to evaluate and monitor radiation exposure and image quality separately.

Analysis of the root position and angulation of maxillary premolars in alveolar bone using cone-beam computed tomography

  • Yun-Hoa, Jung;Bong-Hae, Cho;Jae-Joon, Hwang
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.365-373
    • /
    • 2022
  • Purpose: This study investigated whether the relationship between the maxillary sinus and the root of the maxillary premolar is correlated with the root position and whether there is a difference in the long axis angle of premolars and the buccal bone thickness according to the sinus-root relationship and root position. Materials and Methods: Cone-beam computed tomographic images of 587 maxillary first premolars and 580 second premolars from 303 patients were retrospectively reviewed. The maxillary sinus floor-root relationship was classified into 4 types, and the root position in the alveolar bone was evaluated as buccal, middle, or palatal. The long axis angle of the maxillary premolars in the alveolar bone and the buccal bone thickness were measured. The correlation between these parameters was analyzed. Results: The maxillary sinus floor-root relationship showed a statistically significant correlation with the root position in the alveolar bone. Most maxillary first premolars were buccally located, and more than half of the second premolars had their roots in the middle. The long axis angle of the premolars was significantly larger in buccal-positioned teeth than in middle-positioned teeth, and the buccal bone was thinner. Conclusion: When the root of the maxillary premolar was separated from the sinus floor, the premolar was often located on the buccal side. Most of the maxillary first premolars had a thinner buccal bone and larger inclination than the second premolars. It is recommended to evaluate the root position, sagittal angle and buccal bone thickness using CBCT for implant treatment planning.

Dental age estimation in Indonesian adults: An investigation of the maxillary canine pulp-to-tooth volume ratio using cone-beam computed tomography

  • Khamila Gayatri Anjani;Rizky Merdietio Boedi;Belly Sam;Fahmi Oscandar
    • Imaging Science in Dentistry
    • /
    • 제53권3호
    • /
    • pp.221-227
    • /
    • 2023
  • Purpose: This study was performed to develop a linear regression model using the pulp-to-tooth volume ratio (PTVR) ratio of the maxillary canine, assessed through cone-beam computed tomography (CBCT) images, to predict chronological age (CA) in Indonesian adults. Materials and Methods: A sample of 99 maxillary canines was collected from patients between 20 and 49.99 years old. These samples were obtained from CBCT scans taken at the Universitas Padjadjaran Dental Hospital in Indonesia between 2018 and 2022. Pulp volume (PV) and tooth volume (TV) were measured using ITK-SNAP, while PTVR was calculated from the PV/TV ratio. Using RStudio, a linear regression was performed to predict CA using PTVR. Additionally, correlation and observer agreement were assessed. Results: The PTVR method demonstrated excellent reproducibility, and a significant correlation was found between the PTVR of the maxillary canine and CA(r= -0.74, P<0.01). The linear regression analysis showed an R2 of 0.58, a root mean square error of 5.85, and a mean absolute error of 4.31. Conclusion: Linear regression using the PTVR can be effectively applied to predict CA in Indonesian adults between 20 and 49.99 years of age. As models of this type can be population-specific, recalibration for each population is encouraged. Additionally, future research should explore the use of other teeth, such as molars.

Fractal dimension, lacunarity, and cortical thickness in the mandible: Analyzing differences between healthy men and women with cone-beam computed tomography

  • Ingrid Garcia Santos;Fernanda Ramos de Faria;Marcio Josse da Silva Campos;Beatriz Alvares Cabral de Barros;Gustavo Davi Rabelo;Karina Lopes Devito
    • Imaging Science in Dentistry
    • /
    • 제53권2호
    • /
    • pp.153-159
    • /
    • 2023
  • Purpose: The objective of this study was to assess the fractal dimension, lacunarity, trabecular microarchitecture parameters, and cortical linear measurements in the mandibles of male and female individuals to identify differences between them. Materials and Methods: In total, 116 cone-beam computed tomography scans of healthy individuals of different ages (57 men and 59 women, aged between 20 and 60 years) were selected. The following bone parameters were measured: 1) buccal, lingual, and basal cortical bone thickness in 5 standard parasagittal sections (the midline, the left and right sides of the lower lateral incisors, and the left and right sides of the lower canines); 2) the bone volume fraction of 10 sequential axial sections from each patient by creating a volume of interest in the area between the lower canines; and 3) fractal dimension and lacunarity using grayscale images of the same region of the volume of interest in the anterior mandible. Spearman correlation coefficients and the Mann-Whitney test were used. Results: A significant and positive correlation was found between age and cortical thickness, especially in the region of the central incisors. Significant differences between sexes in terms of fractal dimension, lacunarity, and bone volume were found. Women revealed lower fractal dimension values and higher lacunarity and bone volume ratio values than men. Conclusion: Fractal dimension, lacunarity, trabecular bone volume, and cortical thickness were different between men and women of different ages.