• 제목/요약/키워드: Compressor room

검색결과 77건 처리시간 0.029초

무부하 압축기에 의한 냉장고 기계실 소음의 능동제어 (Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator)

  • 구정모;정의봉;김태훈;홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.475-482
    • /
    • 2016
  • The active control of noise generated by the compressor and transmitted out of the machine room through the windows is implemented based on the FIR filter. The machine room contains most of noise sources of electric home appliances, air-conditioners and refrigerators, for example. To actively reduce the noise from the machinery room. In this paper, the transfer function of the controller for minimization of the acoustic power transmitted through the windows is mathematically formulated. The transfer functions required for implementation of the active controller are the measured. The measurements are conducted in this initial stage under the operation of the compressor with no load. For improvement of the reliability of the transfer function of the compressor to the acoustic power, additional operational measurements are performed. The real time controller is implemented based on the FIR filter using the measured transfer functions and the performance of the active controller is estimated. Control performance is measured about 3 dB ~ 10 dB in reduction of the sound power at the peaks of the compressor noise.

Performance of a 2 Room Multi-Heat Pump with a Constant Speed Compressor

  • Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.184-191
    • /
    • 2004
  • In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.

로터리 컴프레서 방사소음의 실험적 저감 (Experimental Reduction of the Noise Radiated by Rotary Compressor)

  • 박상영;이상현;이수일;이장무
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.189-195
    • /
    • 1999
  • The noise radiated by the rotary compressor for a room air-conditioner was investigated experimentally. Noise characteristics and structural eigen modes of the compressor were identified through sound tests and modal tests each other. From these tests. we found that the accumulator has a big contribution to the noise radiation. So, various structural modifications for the accumulator were performed and these modification methods were found efficient to the noise reduction from verification tests.

  • PDF

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

2방식 응축을 이용한 수산물 건조 장치 개발 (Development of drying apparatus using 2-way condensation for marine products)

  • 황재호
    • 수산해양기술연구
    • /
    • 제42권4호
    • /
    • pp.259-266
    • /
    • 2006
  • In this study, the 2-way condensation system was designed applying air-to-air heat pump to dry a marine product such as squid in the winter. And to be made the drying apparatuses by this system, there are two kinds of type, A type, was set a compressor outside of the drying apparatus, B type, was set a compressor in the drying room. And then the variations of temperature in drying room were measured to compare the heating performance of the drying apparatuses between A type and B type at $-6.5^{\circ}C$, outdoor temperature. The temperature of the drying room for B type was increased to $36^{\circ}C$ but the temperature of the drying room for A type was not increased to $36^{\circ}C$, to be increased to $20^{\circ}C$.

가스추진 LNG 운반선의 가스 압축기실에 설치된 가스검출장치의 최적 배치에 관한 연구 (Optimal Gas Detection System in Cargo Compressor Room of Gas Fueled LNG Carrier)

  • 이상원;소예덕;이승훈;이진욱;정은석;강호근
    • 해양환경안전학회지
    • /
    • 제25권5호
    • /
    • pp.617-626
    • /
    • 2019
  • 본 연구는 가스추진 174K급 LNG 운반선의 가스 압축기실에서 발생하는 가스누출 모사를 통해 가스탐지기의 최적 위치를 분석하였으며, 새로 개정된 IGC 코드에 명시된 안전규정을 만족하는 합리적인 방법도 함께 제안하였다. 가스압축기실에서의 LNG 가스누출 수치해석을 위해, 실제 ME-GI 엔진이 장착된 174K급 LNG 운반선의 압축기실 형상과 장비, 배관의 배치와 같은 치수로 3D 설계되었다. 가스누설에 대한 시나리오는 305 bar의 높은 압력과 1 bar의 낮은 압력을 적용하여 진행하였다. 고압용 핀홀의 크기는 4.5, 5.0, 5.6 mm이고 저압용은 100, 140 mm이다. 해석 결과, 5.6 mm 핀홀(고압)과 100, 140 mm 핀홀(저압) 상태의 누출에 대한 환기평가에서 가연성 가스농도는 심각한 위험이 없음을 확인하였다. 그러나 개정된 IGC 코드에 따라 설치된 압축기실의 가스 감지 센서의 실제 위치는 다른 지점으로 이동해야 하고, 측정 지점이 현 규정에서 요구하는 것보다 더 추가되어야 함을 확인하였다.

실외기 소음원 규명 및 소음저감 (Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner)

  • 서상호;이근동;이내영;진심원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.575-581
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC(Room Air Conditioner) are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan, heat exchanger and shroud. First, the fluid noise is reduced through the design ol new fan and shroud with high flow rate and low noise, reduction of the system resistance by rearrangement of heat exchanger, and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4-5dB(A).

  • PDF

RecurDyn 을 이용한 압축기 및 배관 진동 해석 (Vibration Analysis of Compressor and Pipe Using RecurDyn)

  • 권승민;손영부;하종훈;유홍희
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권2호
    • /
    • pp.117-124
    • /
    • 2015
  • 최근 생활수준의 향상으로 인해 가정용 에어컨의 보급률이 꾸준히 증가함에 따라 품질에 대한 소비자의 눈높이 또한 점점 높아지고 있다. 과거에 소비자의 요구는 제품의 효율성에 집중되었지만 점차 저진동/저소음에 대한 부분으로 확장되고 있다. 에어컨의 압축기는 제품의 효율을 결정하는 주요한 부분이면서 동시에 진동/소음의 주된 원인을 제공하고 있다. 압축기에서 발생한 진동/소음은 압축기 케이스와 배관을 통해 주위 구조물로 전달되고 이들은 다시 구조기인 소음이나 2 차적인 진동을 유발하게 된다. 본 연구에서는 RecurDyn 을 이용해 압축기의 진동/소음에 영향을 미치는 모터의 가진력이 고려된 MFBD(Multi Flexible Body Dynamics) 해석 모델을 개발하였다. 개발된 모델을 이용하여 압축기의 진동/소음 특성을 조사하고 압축기에서 발생하는 진동을 계산하여 실험 결과와 비교하였다.

구조 변경 기법을 이용한 로타리 컴프레서의 방사소음특성 분석 및 소음저감

  • 박상영;이상현;이수일;이승갑;박윤서
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.778-781
    • /
    • 1995
  • In this paper, sound radiation of a rotary compressor used in room air-conditioner is investigated. structural eigenmodes are identified through modal test. Since accumulator is found important factor of sound radiation, damping material was added around accumulator to reduce sound radiation level of rotary compressor. As result, sound radiation was reduced to 3 dB.

  • PDF

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.