• Title/Summary/Keyword: Compression Rate(CR)

Search Result 19, Processing Time 0.022 seconds

High Temperature Creep Behavior of Cr3C2 Composites (크롬-카바이드 복합체의 고온 크리프 거동)

  • 김지환;한동빈;김기태
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.11
    • /
    • pp.1219-1226
    • /
    • 1995
  • Creep behaviors of Cr3C2 composites containing 90 wt% Cr3C2 and 10 wt% Ni were studied at high temperature. Compression tests at 100$0^{\circ}C$ and bending tests at 100$0^{\circ}C$ and 105$0^{\circ}C$ were done in argon environment. In all test conditions primary and steady-state creep behaviors were observed. Stress exponent and activatiion energy were determined from the experimental data. By microstructural analysis of Cr3C2 composites after creep test, the separate agglomerations of Ni phase were observed. Numerical analysis was also studied to analyze bending creep behaviors of Cr3C2 by assumming different tensile and compressive creep behavior in a bending sample. From the analysis, it was found that the stress state at the compressive region as applied stress increased. The observed creep rates were compared with the predicted creep rates by estimating power-law creep parameters from bending test data.

  • PDF

Effects of CR Contents on Rubber Vulcanization and Mechanical Properties of NR/CR Blends (NR/CR 고무블랜드에서의 CR조성비가 가황 및 물성에 미치는 영향)

  • Ahn, Won-Sool;Park, Dong-Ryul
    • Elastomers and Composites
    • /
    • v.46 no.2
    • /
    • pp.152-157
    • /
    • 2011
  • Effects of CR contents in NR/CR blends on the vulcanization kinetics and miscibility were studied by dynamic DSC and TGA, as well as the mechanical properties. While the vulcanization activation energy showed a constant value of $77.5{\pm}2.5$ kcal/mol regardless of CR contents, reaction rate, however, was observed to be somewhat lowered at increased CR contents. Partial miscibility was found between NR and CR phases at lower CR content of 3 wt%, but immiscibility was observed at higher CR content of 21 wt%. Mechanical properties were also affected by this miscibility, showing linear increase of compression set but decrease of tensile strength with CR contents in the blends.

High Temperature Deformation Behavior of L12 Modified Titanium Trialuminides Doped with Chromium and Copper (크롬 및 구리로 치환한 L12 Titanium Trialuminides합금의 고온변형거동)

  • Han, Chang-Suk;Jin, Sung-Yooun;Bang, Hyo-In
    • Korean Journal of Materials Research
    • /
    • v.28 no.6
    • /
    • pp.317-323
    • /
    • 2018
  • Crystal structure of the $L1_2$ type $(Al,X)_3Ti$ alloy (X = Cr,Cu) is analyzed by X-ray diffractometry and the nonuniform strain behavior at high temperature is investigated. The lattice constants for the $L1_2$ type $(Al,X)_3Ti$ alloys decrease in the order of the atomic number of the substituted atom X, and the hardness tends to increase. In a compressive test at around 473K for $Al_{67.5}Ti_{25}Cr_{7.5}$, $Al_{65}Ti_{25}Cr_{10}$ and $Al_{62.5}Ti_{25}Cu_{12.5}$ alloys, it is found that the stress-strain curves showed serration, and deformation rate dependence appeared. It is assumed that the generation of serration is due to dynamic strain aging caused by the diffusion of solute atoms. As a result, activation energy of 60-95 kJ/mol is obtained. This process does not require direct involvement. In order to investigate the generation of serrations in detail, compression tests are carried out under various conditions. As a result, in the strain rate range of this experiment, serration is found to occur after 470K at a certain critical strain. The critical strain increases as the strain rate increases at constant temperature, and the critical strain tends to decrease as temperature rises under constant strain rate. This tendency is common to all alloys produced. In the case of this alloy system, the serration at around 473K corresponds to the case in which the dislocation velocity is faster than the diffusion rate of interstitial solute atoms at low temperature.

Characteristic Evaluation of Impact Absorption Materials for the Development of Fall Impact Protective Pants (낙상 보호 팬츠개발을 위한 충격흡수 소재특성 평가)

  • Park, Jung Hyun;Lee, Jin Suk;Lee, Jeong Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.3
    • /
    • pp.495-505
    • /
    • 2016
  • This study explores and selects an appropriate material that considers light and soft physical properties as well as activity for impact absorption pads that can be used to develop practical impact protective clothes worn during daily life by the elderly to reduce the impact of falls. Physical properties, impact absorption performance, and compression characteristics were evaluated on 5 types of foam, 2 types of 3D spacer fabric, and 3 types of polymer gel to select a material appropriate for the pad to be inserted into impact protective clothes. The evaluation of the physical properties showed that 3D spacer fabrics had lower density compared to other materials and polymer gels had the highest density. The elongation percentage was higher in foams than 3D spacer fabrics and EPDM foam had the highest elongation percentage. The impact absorption performance of honeycomb polymer gel was better than foams and 3D spacer fabrics. As a result of looking into compression energy and compression characteristics of materials, 'CR foam A' was found to absorb the largest amount of compression energy, 24.1%, among foams and polymer gels. A high energy absorption rate of 50.0% (or above) was indicated by 3D spacer fabrics; however, foams and polymer gels showed a progressive deformation of energy compression / recovery curve with 3D spacer fabrics that showed drastic deformation. Based on characteristics of materials, 'CR foam C' and EPDM with relatively high absorption performance can be used as protective pad materials among foams. Among polymer gels, 2 open-type polymer gels that have relatively low impact protective performance but a relatively lighter weight on human body (compared to closed-type) are considered appropriate protective pad materials.

A Study on the Data Compression of the Voice Signal using Multi Wavelet (다중 웨이브렛을 이용한 음성신호 데이터 압축에 관한 연구)

  • Kim, Tae-Hyung;Park, Jae-Woo;Yoon, Dong-Han;Noh, Seok-Ho;Cho, Ig-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.625-629
    • /
    • 2005
  • According to the rapid development of the information and communication technology, the demand on the efficient compression technology for the multimedia data is increased magnificently. In this Paper, we designed new compression algorithm structure using wavelet base for the compression of ECG signal and audible signal data. We examined the efficiency of the compression between 2-band structure and wavelet packet structure, and investigated the efficiency and reconstruction error by wavelet base function using Daubechies wavelet coefficient and Coiflet coefficient for each structure. Finally, data were compressed further more using Huffman code, and resultant Compression Rate(CR) and Percent Root Mean Square difference(PRD) were compared with those of existent DCT.

  • PDF

Efficient Signaling of Extended GPM Modes in ECM (ECM 의 효율적인 GPM 확장 모드 시그널링 기법)

  • Moon, Gihwa;Lee, Jiwon;Park, Dohyeon;Kim, Jae-Gon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.1236-1238
    • /
    • 2022
  • JVET 은 최신 비디오 부호화 표준인 VVC(Versatile Video Coding) 표준화를 완료한 후, VVC 보다 더 높은 압축 성능을 가지는 새로운 표준기술 탐색을 진행하고 있으며, 이를 위하여 참조 소프트웨어 ECM(Enhanced Compression Model)을 개발하고 있다. 현재 ECM4.0 에는 다양한 후보 구성 및 예측 성능 개선 기법을 추가하여 기존 VVC 의 GPM(Geometric Partitioning Mode)을 확장한 GPM-MMVD(GPM with merge MV differences), GPM-TM(GPM with template matching) 등을 채택하고 있다. 본 논문에서는 ECM 에 채택된 확장된 GPM 기술들의 각 기술 별 선택 빈도를 분석하고 이를 바탕으로 보다 효율적인 GPM 확장 모드 시그널링 방식을 제안한다. 또한 후보 탐색 알고리즘을 간소화한 복잡도 감소 기법을 제시한다. 실험결과 제안하는 시그널링 기법은 ECM4.0 대비 Y와 Cb, Cr 에서 각각 0.02%, 0.16%, 0.09% BD-rate 부호화 성능 향상을 보였고 GPM 인덱스 탐색 간소화 기법은 ECM4.0 대비 Y 와 Cr 에서 각각 0.02%, 0.18% BD-rate 부호화 성능 향상을 보였다.

  • PDF

Application of Biosignal Data Compression for u-Health Sensor Network System (u-헬스 센서 네트워크 시스템의 생체신호 압축 처리)

  • Lee, Yong-Gyu;Park, Ji-Ho;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.352-358
    • /
    • 2012
  • A sensor network system can be an efficient tool for healthcare telemetry for multiple users due to its power efficiency. One drawback is its limited data size. This paper proposed a real-time application of data compression/decompression method in u-Health monitoring system in order to improve the network efficiency. Our high priority was given to maintain a high quality of signal reconstruction since it is important to receive undistorted waveform. Our method consisted of down sampling coding and differential Huffman coding. Down sampling was applied based on the Nyquist-Shannon sampling theorem and signal amplitude was taken into account to increase compression rate in the differential Huffman coding. Our method was successfully tested in a ZigBee and WLAN dual network. Electrocardiogram (ECG) had an average compression ratio of 3.99 : 1 with 0.24% percentage root mean square difference (PRD). Photoplethysmogram (PPG) showed an average CR of 37.99 : 1 with 0.16% PRD. Our method produced an outstanding PRD compared to other previous reports.

CR-DPCM for Lossless Intra Prediction Method in HEVC (CR-DPCM을 이용한 HEVC 무손실 인트라 예측 방법)

  • Hong, Sung-Wook;Lee, Yung-Lyul
    • Journal of Broadcast Engineering
    • /
    • v.19 no.3
    • /
    • pp.307-315
    • /
    • 2014
  • A new modified lossless intra-coding method based on a cross residual transform is applied to HEVC(High Efficiency Video Coding). The HEVC standard including a multi-directional spatial prediction method to reduce spatial redundancy encodes the pixels in a PU (Prediction Unit) by using neighboring pixels. In the new modified lossless intra-coding method, the spatial prediction is performed by pixel-based DPCM but is implemented by block-based manner by using cross residual transform on the HEVC standard. The experimental results show that the new lossless intra-coding method reduces the bit rate of approximately 8.4% in comparison with the lossless-intra coding method in the HEVC standard and the proposed method results in slightly better compression ratio than the JPEG2000 lossless coding.

Effect of Microstructure on the High Deformation Stability of Incoloy 825 Alloy (Incoloy 825 합금의 고온 변형 안정성에 미치는 미세조직의 영향)

  • Kang, Chang-Yong;Kim, Seong-Hwi;Park, Young-Tae
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.20-26
    • /
    • 2017
  • This study was carried out to investigate the effect of precipitate on the high temperature deformation stability of incoloy 825 alloy. $Cr_{23}C_6$ carbide was precipitated under $950^{\circ}C$, but was not detected over $1,000^{\circ}C$. Most of the precipitation consist of $Cr_{23}C_6$ carbide. Strain-rate sensitivity was the highest in 0.01/s and the lowest in 10/s. Strain-rate sensitivity was decreased sharply below $950^{\circ}C$. In the temperature between $850^{\circ}C{\sim}1,150^{\circ}C$, plastic instable area did not exist. It showed the lowest Ziegler Parameter value of 0.06 Ziegler Parameter was the lowest as 0.06 at $850^{\circ}C$ with 10s-1 of strain. The highest Ziegler Parameter value(0.43) was found in plastic deformation at $1,050^{\circ}C$ with 0.01s-1 of strain. It tends to have an higher resistance to the high temperature deformation under $950^{\circ}C$, due to the precipitation.

ECG Compression Structure Design Using of Multiple Wavelet Basis Functions (다중웨이브렛 기저함수를 이용한 심전도 압축구조설계)

  • Kim Tae-hyung;Kwon Chang-Young;Yoon Dong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.467-472
    • /
    • 2005
  • ECG signals are recorded for diagnostic purposes in many clinical situations. Also, In order to permit good clinical interpretation, data is needed at high resolutions and sampling rates. Therefore In this paper, we designed to compression structure using multiple wavelet basis function(SWBF) and compared to single wavelet basis function(SWBF) and discrete cosine transform(DCT). For experience objectivity, Simulation was performed using the arrhythmia data with sampling frequency 360Hz, resolution lIbit at MIT-BIH database. An estimate of performance estimate evaluate the reconstruction error. Consequently compression structure using MWBF has high performance result.