• 제목/요약/키워드: Composition calculation

검색결과 236건 처리시간 0.025초

Web-based Daily Report for Data Repository of Standard Cost Data for Modernized Korean Housing (Hanok)

  • Kim, SuJi;Jung, Youngsoo
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.595-596
    • /
    • 2015
  • Growing demand for traditional Korean housing, modernized Korean traditional housing (Hanok) was developed as a way of providing Hanok for the public. However, the standard cost data for Hanok has limitations, as it was developed based on single mock-up project actually constructed and verified by another mock-up Hanok. In order to meet these research objectives, daily report composition which is easy-to-use for on-site workers and managers and also easy-to-accumulate standard cost data was developed first. Secondly, access to the system was made easy through a web server. Finally, an automated calculation formula was inserted to allow the last inputted data to be automatically included for adjustment of standard costs. This system was designed from an industry perspective so that any unspecified and nonprofessional users can easily use. For the users, it has an advantage that on-site workers are provided with a daily report system through web server and also they are able to complete such reports through simple input and output without any additional forms.

  • PDF

동위원소를 이용한 하수 내 지하수 및 우수 함량 산출: 전주 덕진공원 유역 사례 (Calculation of Rainwater and Groundwater Fraction in Sewerage: A Case Study in Deokjin Park, Jeonju)

  • 최승현;김강주;문상호
    • 자원환경지질
    • /
    • 제49권5호
    • /
    • pp.361-370
    • /
    • 2016
  • 하수관거에 지하수가 침투하고 우수가 유입(I/I)되게 되면 하수의 양이 크게 늘어나 하수처리장의 부하가 가중되고, 하수의 처리효율도 크게 감소되기 때문에, 하수 중의 I/I를 알아내는 것은 매우 중요하다. 본 연구는 산소 및 수소 동위원소를 이용한 I/I 측정가능성 검토를 목적으로 수행되었으며, 이를 위하여 전주시 덕진공원 유역 내 관정 지하수 및 수로수, 상수도 등에 대하여 동위윈소적 조사를 수행하였다. 본 연구를 통하여 전주지역의 상수도는 전주에서 내륙으로 약 40 km 떨어진 고지대에 위치한 용담댐을 수원으로 하기 때문에 지역 강우와는 뚜렷이 다른 동위원소적 특성을 보이고, 시간에 따른 조성의 변화도 거의 없음을 알게 되었다. 하수는 기본적으로 상수도에서 발생하므로, 상수도와 지역강우를 양극단으로 하여 하수로 내 지역강우의 함량을 계산할 수 있다. 이러한 방법으로 덕진공원 유역 내하수로 1개 지점에서 지역강우의 함량을 계산한 결과, 강우가 시기에 따라 하수의 50%에서 90%를 차지하는 것으로 확인되었다. 이러한 계산결과는 오염농도가 높지 않은 하수의 수질을 통하여도 잘 뒷받침된다. 같은 방법으로 계산된 지하수내 상수도의 함량도 약 46%나 되었으며, 이는 상수도의 누수가 중요한 지하수원이 되고 있음을 지시하는 것이다. 이러한 동위원소 조성을 갖는 지하수는 하수로에 유입되어도 하수의 동위원소에는 크게 영향을 주지 않기 때문에 실제로 하수로에 유입되는 우수와 지하수의 량은 계산 결과보다 훨씬 클 것으로 예상된다.

이란산 원유의 증발에 따른 풍화율 및 화학적 성상 변화 (Effects of Evaporation on the Weathering Rate and Chemical Composition of Iranian Heavy Crude Oil)

  • 김범;김기범;심원준;임운혁
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제15권3호
    • /
    • pp.238-246
    • /
    • 2012
  • 해양으로 유출된 유류는 다양한 풍화과정을 통해 환경에서 제거되며, 증발이 유출사고 초기에 가장 우세한 풍화과정이다. 본 연구에서는 허베이스피리트호 사고유 중 이란산 원유를 대상으로 실험실에서 표준화된 증발실험을 실시하여 시간에 따른 물리화학적 변화를 관찰하였다. 증발과정에 영향을 미치는 유막두께, 풍속 등의 변수를 제어하여 48시간까지 노출한 결과 $29.3{\pm}0.4%$의 재현성 있는 결과를 산출하였다(n=40, p<0.001). 미국해양대기청의 풍화모델인 ADIOS2를 이용하여 환경조건에서 증발을 시뮬레이션한 결과 29%의 증발율을 구할 수 있었으며, 본 실험과 일치하는 결과를 확인하였다. 증발율에 따른 원유의 조성변화를 분석한 결과 저분자량의 알칸과 PAHs가 제거되었으나, 바이오마커 화합물은 증발에 의한 영향을 받지 않는 보전적인 특성을 나타냈다. 바이오마커 중 $17{\alpha}(H)$, $21{\beta}(H)$-hopane을 이용한 풍화율 계산값은 48시간 최종 값이 24.4%로 물리적인 증발에 따른 양적변화와 유사한 결과를 보였다. 호판을 이용한 풍화율 계산값 비교결과 사고 초기 현장 표착유(1단계 풍화 28.9%)와 메소코즘 풍화 실험 5일차(26.5%)까지는 풍화과정이 주로 증발에 의한 것으로 확인되었다.

합성 PC부재에 의한 그린 프레임의 철근물량 산출 자동화 알고리즘 (Automatic Algorithms of Rebar Quantity Take-Off of Green Frame by Composite Precast Concrete Members)

  • 이성호;김선형;이군재;김선국;주진규
    • 한국건설관리학회논문집
    • /
    • 제13권1호
    • /
    • pp.118-128
    • /
    • 2012
  • 1980년대 이후 국내 아파트에서 적용되어온 벽식구조는 리모델링 시 많은 문제점을 유발시켜 정부에서는 법적 인센티브를 제공하며 무량판 및 라멘구조를 장려하고 있다. 이에 따라 기존의 골조의 문제점을 개선한 친환경 라멘조인 그린 프레임이 개발되어 구조적 안전성 뿐 아니라 시공성, 친환경성에 대한 검증이 이루어졌다. 그린프레임의 경우 설계단계에서 작성된 프리캐스트 콘크리트(Precast Concrete; PC) 부재 정보를 이용하여 물량 산출 및 철근 가공도(bar bending schedule) 등을 자동으로 작성하면 인력저감 뿐 아니라 철근 손율(loss)을 줄이는 철근조합을 용이하게 수행할 수 있다. 따라서 본 연구는 합성 PC부재에 의해 설계된 그린 프레임의 철근물량 산출 자동화 알고리즘을 개발하는 것을 목적으로 한다. 철근물량 산출자동화 알고리즘은 구조 설계정보, 시방정보, 합성PC의 철골정보 등을 이용하여 작성한 후 사례현장 적용을 통하여 개발된 알고리즘의 효용성을 증명한다. 개발된 알고리즘에 의해 저장된 정보는 철근가공조립도, 철근 재단 리스트(bar cutting list)작성 자동화 뿐 아니라 철근 손율을 최소화 할 수 있는 최적조합과 주문물량 산출 자동화에도 활용될 것이다. 또한 공사관리인력 저감 뿐 아니라 철근 손율 최소화 관리에 따른 공사 원가절감의 효과를 기대할 수 있다.

질화물계 반도체 GaP1-X NX의 에너지 밴드갭 계산 (The Calculation of the Energy Band Gaps of Zincblende GaP1-X NX)

  • 정호용;김대익
    • 한국전자통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.783-790
    • /
    • 2017
  • 본 연구에서는 무질서 효과가 고려된, 새로이 가정한 가상 결정 근사법을 갖는 empirical pseudopotential method를 사용하여 온도와 조성비 변화에 따른 3원계 질화물계 화합물 반도체 GaP1-xNx의 휨 매개변수 및 에너지 밴드갭을 계산하였다. 300K의 조성비 구간($0{\leq}x{\leq}0.05$)에서 에너지 밴드갭들이 급격히 감소하며, 해당하는 계산된 휨 매개변수가 13.1eV임을 알 수 있었다. 에너지 밴드갭 계산 결과로부터 굴절률 n과 실수부 유전상수 함수 ${\varepsilon}$를 계산하였고, 에너지 밴드갭 계산 결과는 실험치를 대체로 잘 설명하였다.

자연수의 혼합계산에 대한 초등학생들과 예비교사들의 오류 분석 (An Analysis on the Error Types of Elementary Students and Pre-service Teachers in Mixed Calculations of Natural Number)

  • 이대현
    • 한국학교수학회논문집
    • /
    • 제20권2호
    • /
    • pp.141-161
    • /
    • 2017
  • 초등학교에서 자연수의 혼합계산은 사칙계산이 섞여 있는 수식의 계산 순서를 알고 해결할 수 있는 능력을 길러 주는데 초점을 두고 있다. 이런 목표에 비추어 본 연구에서는 초등학생 67명과 예비교사 57명을 대상으로 수식과 문장제로 이루어진 검사지를 이용하여 혼합계산에 대한 해결 정도와 오류 유형을 분석하였다. 검사 결과, 초등학생들은 수식과 문장제로 된 혼합계산에서 86.2%와 73.5%의 정답률과 수식에서 계산 순서의 오류, 문장제에서 수식을 구성하지 못하는 오류를 나타내었다. 예비교사들의 경우에 나타난 몇 개의 오류와 해결과정에 비추어 혼합계산이 이루어지는 식의 계산 원리와 규약을 이해할 수 있도록 교과 교육 내용을 유의해서 지도할 필요를 제시하였다. 또한 검사 결과를 통해 혼합계산 시 괄호 사용의 유무와 적절성, 등호 개념의 사용 방법에서 문제점을 확인할 수 있었다.

  • PDF

대전 4공단 소각로 후연소로 모델 연구 (Numerical Study of the Post Combustion Chamber of Grate Type Incinerator in Daejon 4th Industrial Complex)

  • 김혜숙;신미수;장동순;박병수;엄태인
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 추계 학술대회논문집
    • /
    • pp.133-138
    • /
    • 2002
  • A 3-D axisymmetric computer program is developed to predict the NO behavior in SNCR system for the stoker incinerator with the waste treatment capacity, 200ton/day. To this end a turbulent reacting flow field calculation is made using proper assumption and empiricism. The stoker bed is assumed to be a homogeneous waste-volatilized gaseous state. The initial composition or reactants are assumed based on the data of the ultimate analysis. Turbulent is resolved by k-e model and turbulent reaction is handled by eddy-breakup model harmonized with empirical chemistry data for gaseous combustion, NO and urea reaction. The liquid droplet is traced by Lagrangian method incorporated by aerodynamic drag, Coriolis and crntrifugal forces. Radiation is treated by sensible heat loss model. Calculation results are in good agreement with experimental data at the outlet of post combustion chamber in Daejon 4th industrial complex. The flue gas shows the temperature range of $900\sim1000^{\circ}C$, velocity of 5m/s and NO concentration of 140ppm at the exit while the measured temperature, flue gas velocity and NO concentration are $967^{\circ}C$, $3\sim4m/s$ and $100\sim200ppm$respectively. Using the developed computer program a parametric study has been made with the variation of heat content of waste, castable length and SNCR variables for the determination of proper injector location. In general, the calculated results are consistent and physically acceptable.

  • PDF

창호를 통한 열전달 현상에 관한 연구 (A Study on the Heat Transfer Phenomenon through the Glazing System)

  • 강은율;오명원;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

RADIOLOGICAL CHARACTERISTICS OF DECOMMISSIONING WASTE FROM A CANDU REACTOR

  • Cho, Dong-Keun;Choi, Heui-Joo;Ahmed, Rizwan;Heo, Gyun-Young
    • Nuclear Engineering and Technology
    • /
    • 제43권6호
    • /
    • pp.583-592
    • /
    • 2011
  • The radiological characteristics for waste classification were assessed for neutron-activated decommissioning wastes from a CANDU reactor. The MCNP/ORIGEN2 code system was used for the source term analysis. The neutron flux and activation cross-section library for each structural component generated by MCNP simulation were used in the radionuclide buildup calculation in ORIGEN2. The specific activities of the relevant radionuclides in the activated metal waste were compared with the specified limits of the specific activities listed in the Korean standard and 10 CFR 61. The time-average full-core model of Wolsong Unit 1 was used as the neutron source for activation of in-core and ex-core structural components. The approximated levels of the neutron flux and cross-section, irradiated fuel composition, and a geometry simplification revealing good reliability in a previous study were used in the source term calculation as well. The results revealed the radioactivity, decay heat, hazard index, mass, and solid volume for the activated decommissioning waste to be $1.04{\times}10^{16}$ Bq, $2.09{\times}10^3$ W, $5.31{\times}10^{14}\;m^3$-water, $4.69{\times}10^5$ kg, and $7.38{\times}10^1\;m^3$, respectively. According to both Korean and US standards, the activated waste of the pressure tubes, calandria tubes, reactivity devices, and reactivity device supporters was greater than Class C, which should be disposed of in a deep geological disposal repository, whereas the side structural components were classified as low- and intermediate-level waste, which can be disposed of in a land disposal repository. Finally, this study confirmed that, regardless of the cooling time of the waste, 15% of the decommissioning waste cannot be disposed of in a land disposal repository. It is expected that the source terms and waste classification evaluated through this study can be widely used to establish a decommissioning/disposal strategy and fuel cycle analysis for CANDU reactors.

탄화규소 CVD 공정에서 CH3SiCl3-H2과 C3H8-SiCl4-H2계의 열역학적 비교 (Thermodynamic Comparison of Silicon Carbide CVD Process between CH3SiCl3-H2 and C3H8-SiCl4-H2 Systems)

  • 최균;김준우
    • 대한금속재료학회지
    • /
    • 제50권8호
    • /
    • pp.569-573
    • /
    • 2012
  • In order to understand the difference in SiC deposition between the $CH_3SiCl_3-H_2$ and $C_3H_8-SiCl_4-H_2$ systems, we calculate the phase stability among ${\beta}$-SiC, graphite and silicon. We constructed the phase-diagram of ${\beta}$-SiC over graphite and silicon via computational thermodynamic calculation considering pressure (P), temperature (T) and gas composition (C) as variables. Both P-T-C diagrams showed a very steep phase boundary between the SiC+C and SiC region perpendicular to the H/Si axis, and also showed an SiC+Si region with a H/Si value of up to 6700 in the $C_3H_8-SiCl_4-H_2$, and 5000 in the $CH_3SiCl_3-H_2$ system. This difference in phase boundaries is explained by the ratio of Cl to Si, which is 4 for the $C_3H_8-SiCl_4-H_2$ system and 3 for the $C_3H_8-SiCl_4-H_2$ system. Because the C/Si ratio is fixed at 1 in the $CH_3SiCl_3-H_2$ system while it can be variable in the $C_3H_8-SiCl_4-H_2$ system, the functionally graded material is applicable for better mechanical bonding during SiC coating on graphite substrate in the $C_3H_8-SiCl_4-H_2$ system.