• 제목/요약/키워드: Composed Unit Cost

검색결과 80건 처리시간 0.036초

기능 분석에 따른 제품 원가 구조개선 알고리즘에 대한 연구 (The Algorithm of Improvement of Production cost using Function based cost estimating)

  • 서지한;이재명;나승훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.207-213
    • /
    • 2010
  • Now days, the marketing environment is rapidly changed. Therefore, a lot of companies try to reduce production cost. Especially, Design is a important activities in new product development. While the concepts of design for manufacturable and concurrent engineering have made significant advances in integrating the design function with other areas in the firm. There are still major gaps in timely and accurate costing information available to designers. Inappropriate design could result in high redesign cost and delay in product relation. The generation of design and improvement is a time-consuming and mentally exhaustion process. It involves combining design features to generate as many potential design as possible. As not all features combinations are feasible, decision-makers have to narrow down the potential solutions and subsequently select appropriate design for further development. This new study is composed of 3 steps aiming at the Low Cost Design of the product. The three steps are consisted that setting up the target Cost, estimating the current functional cost, the design of a unit's reviewing according to the priority of the difference between the target cost and the functional cost.

명령어 버퍼를 이용한 최적화된 수퍼스칼라 명령어 이슈 구조 (An optimized superscalar instruction issue architecture using the instruction buffer)

  • 문병인;이용환;안상준;이용석
    • 전자공학회논문지C
    • /
    • 제34C권9호
    • /
    • pp.43-52
    • /
    • 1997
  • Processors using the superscalar rchitecture can achieve high performance by executing multipel instructions in a clock cycle. It is made possible by having multiple functional units and issuing multiple instructions to functional units simultaneously. But instructions can be dependent on one another and these dependencies prevent some instructions form being issued at the same cycle. In this paper, we designed an issue unit of a superscalar RISC microprocessor that can issue four instructions per cycle. The issue unit receives instructions form a prefetch unit, and issues them in order at a rate of as high as four instructions in one cycle for maximum utilization of functional units. By using an instruction buffer, the unit decouples instruction fetch and issue to improve instruction ussue rate. The issue unit is composed of an instruction buffer and an instruction decoder. The instruction buffer aligns and stores instructions from the prefetch unit, and sends the earliest four available isstructions to the instruction decoder. The instruction decoder decodes instructions, and issues them if they are free form data dependencies and necessary functional units and rgister file prots are available. The issue unit is described with behavioral level HDL (lhardware description language). The result of simulation using C programs shows that instruction issue rate is improved as the instruction buffer size increases, and 12-entry instruction buffer is found to be optimum considering performance and hardware cost of the instruction buffer.

  • PDF

DP법에 의한 화력계통의 최적병렬치수 결정 및 부하배분 (Determination of optimal unit commitment and load dispatch for thermal power system by DP method)

  • 양흥석;이문호
    • 전기의세계
    • /
    • 제21권2호
    • /
    • pp.34-40
    • /
    • 1972
  • This paper describes the problem of the shortange-economic-scheduling for unit commitment and load dispatching in thermal power system. For economic operation of thermal system, the optimum time of startup and shoutdown of the generating unit must be determined so as to minimize the sum of generating and starting fuel cost over a given period. The above problems are analyzed for the purpose of the application of Dynamic Programing Method. Also the technique of Dynamic Programming is applied to the problems. For the illustative purpose, a case study was made on a model system composed of eight units and the computing time was about 190 seconds by IBM 360-40 system. Therefore, one can utilize this suggested method on any of the practical power systems.

  • PDF

32비트 DSP RISC 프로세서를 위한 ALU 설계 및 테스트 (ALU Design & Test for 32-bit DSP RISC Processors)

  • 최대봉;문병인
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.1169-1172
    • /
    • 1998
  • We designed an ALU(Airthmetic Logic Unit) with BIST(Built-In Self Test), which is suitable for 32-bit DSP RISC processors. We minimized the area of this ALU by allowing different operations to share several hardware blocks. Moreover, we applied DFT(Design for Testability) to ALU and offered Bist(Built-In Self-Test) function. BIST is composed of pattern generation and response analysis. We used the reseeding method and testability design for the high fault coverage. These techniques reduce the test length. Chip's reliability is improved by testing and the cost of testing system can be reduced.

  • PDF

IBM PC를 이용한 심장 박동 간격의 측정 (Heart beat interval measurement using an IBM PC)

  • 이동하;박경수
    • 대한인간공학회지
    • /
    • 제9권1호
    • /
    • pp.3-14
    • /
    • 1990
  • This article develops a cost-effective and accurate measurement system for heart best intervals. The system is composed of an analog to digital (A/D) converter, an IBM personal computer (an 8088 microprocessor, an 8253-5 timer, an 8259A interrupt controller, and memories) and assembler programs for controlling these hardware components. An exponential smoothing algorithm effectively reduced noise effects from A/D converted electrocardiogram (ECG) signals influenced by 60 Hz alternating current (AC). The system can collect 15000 heart beat intervals with an 1/5400 second unit.

  • PDF

전력선 통신을 이용한 원격부하관리시스템 개발 (Development of Remote Load Management System Using PowerLine Communication)

  • 나채동;이성범;정을기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.149-152
    • /
    • 2002
  • In this paper, an simple load management system was introduced. This system is composed of Main Controller, DTU(Dispersion Terminal Unit), Power Line Modem and HMI (Human Machine Interface) program. To control distant loads, network function using powerline communication is implemented in DTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved in a several experiments.

  • PDF

천연가스 개질 방식 중소형 고순도 수소제조 장치 개발 연구 (Study on the development of small-scale hydrogen production unit using steam reforming of natural gas)

  • 서동주;주국택;정운호;박상호;윤왕래
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.720-722
    • /
    • 2009
  • This work is mainly focused at developing the hydrogen production unit with the capacity of 20 $Nm^3/h$ of high purity hydrogen. At present steam reforming of natural gas is the preferable method to produce hydrogen at the point of production cost. The developed hydrogen production unit composed of natural gas reformer and pressure swing adsorption system. To improve the thermal efficiency of steam reforming reactor, the internal heat recuperating structure was adopted. The heat contained in reformed gas which comes out of the catalytic beds recovered by reaction feed stream. These features of design reduce the fuel consumption into burner and the heat duty of external heat exchangers, such as feed pre-heater and steam generator. The production rate of natural gas reformer was 41.7 $Nm^3/h$ as a dryreformate basis. The composition of PSA feed gas was $H_2$ 78.26%, $CO_2$ 18.49%, CO 1.43% and $CH_4$ 1.85%. The integrated production unit can produce 21.1 $Nm^3/h$ of high-purity hydrogen (99.997%). The hydrogen production efficiency of the developed unit was more than 58% as an LHV basis.

  • PDF

종합병원에 입원한 환자의 간호원가 산정에 관한 연구 (Determination of Nursing Costs for Hospitalized Patients Based on the Patient Classification System)

  • 박정호;송미숙
    • 대한간호학회지
    • /
    • 제20권1호
    • /
    • pp.16-37
    • /
    • 1990
  • A cost analysis for hospitalized patients was carried out based upon Patient Classification System(PCS) in order to determine an appropriate nursing fee. The data were collected from 21 nursing units of three teaching hospitals from April 1 to June 30, 1989. first, all of the 22,056 inpatients were classified into mildly ill(Class Ⅰ), moderately ill(Class Ⅱ), acutely ill(Class Ⅲ), and critically ill(Class Ⅳ) by the PCS which had been carefully developed to be suitable for the Korean nursing units. Second. PCS cost accounting was applied to the above data. The distribution of inpatients, nursing costs, and nursing productivity were as follows : 1) Patient distribution ranged from 45% to class Ⅰ, 36% to class Ⅱ, 15% to class Ⅲ, and 4% to class Ⅳ, the proportion of class Ⅳ in ‘H’ Hospital was greater than that of the other two hospitals. 2) The proportion of Class Ⅲ and Ⅳ in the medical nursing units was greater than that of surgical nursing units. 3) The number of inpatients was greatest on Tuesdays, and least on Sundays. 4) The average nursing cost per hour was W 3,164 for ‘S’ hospital, W 3,511 for ‘H’ hospital and W 4,824 for ‘K’ hospital. The average nursing cost per patient per day was W 14,126 for ‘S’ Hospital, W 15,842 for ‘H’ hospital and W 21,525 for ‘K’ hospital. 5) The average nursing cost calculated by the PCS was W 13,232 for class Ⅰ, W 18,478 for class Ⅱ, W 23,000 for class Ⅲ, and W 25,469 for class Ⅳ. 6) The average nursing cost for the medical and surgical nursing units was W 13,180 and W 13,303 respetively for class Ⅰ, W 18,248 and W 18,707 for class Ⅱ, W 22,303 and W 23,696 for class Ⅲ, and W 24,331 and W 26,606 for class Ⅳ. 7) The nursing costs were composed of 85% for wages and fringe benefits, 3% for material supplies and 12% for overhead. The proportion of wages and fringe benefits among the three Hospitals ranged from 75%, 92% and 98% for the ‘S’, ‘H’, ‘K’ hospitals respectively These findings explain why the average nursing cost of ‘K’ hospital was higher than the others. 8) According to a multi- regression analysis, wages and fringe benefits, material supplies, and overhead had an equal influence on determining the nursing cost while the nursing hours had less influence. 9) The productivity of the medical nursing units were higher than the surgical nursing units, productivity of the D(TS) - nursing units was the lowest while the K(Med) - nursing unit was the highest in 'S' hospital. In ‘H’ hospital, productivity was related to the number of inpatients rather than to the characteristics of the nursing units. The ‘K’ hospital showed the same trend as ‘S’ hospital, that the productivity of the medical nursing unit was higher than the surgical nursing unit. The productivity of ‘S’ hospital was evaluated the highest followed by ‘H’ hospital and ‘K’ hospital. Future research on nursing costs should be extended to the other special nursing areas such as pediatric and psychiatric nursing units, and to ICU or operating rooms. Further, the PCS tool should be carefully evaluated for its appropriateness to all levels of institutions(primary, secondary, tertiary). This study took account only of the quantity of nursing services when developing the PCS tool for evaluating the productivity of nursing units. Future research should also consider the quality of nursing services including the appropriateness of nursing activities.

  • PDF

Development of Rotational Motion Estimation System for a UUV/USV based on TMS320F28335 microprocessor

  • Tran, Ngoc-Huy;Choi, Hyeung-Sik;Kim, Joon-Young;Lee, Min-Ho
    • International Journal of Ocean System Engineering
    • /
    • 제2권4호
    • /
    • pp.223-232
    • /
    • 2012
  • For the accurate estimation of the position and orientation of a UUV (unmanned underwater vehicle), a low-cost AHRS (attitude heading reference system) was developed using a low-cost IMU (inertial measurement unit) sensor which provides information on the 3D acceleration, 3D turning rate and 3D earth-magnetic field data in the object coordinate system. The main hardware system is composed of an IMU sensor (ADIS16405) and TMS320F28335, which is coded with an extended kalman filter algorithm with a 50-Hz sampling frequency. Through an experimental gimbal device, good estimation performance for the pitch, roll, and yaw angles of the developed AHRS was verified by comparing to those of a commercial AHRS called the MTi system. The experimental results are here presented and analyzed.

A Study of I/O Serial Communication Systems Between Overground And Overhead Controllers

  • Kim, Duk-Hyun
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.122-128
    • /
    • 2007
  • This paper represents the Input/Output (I/O) serial communication methods between overground and overhead controllers using a programmable logic controller (PLC). In general, the systems composed by overground and overhead controllers use exclusive serial communication units. This, however, has a demerit such as a high cost as well as some restrictions of the system itself. Thus, this paper suggests methods by I/O cards for data communication between overground and overhead controllers. In this system, there is no special card and it therefore has a lower cost and is more flexible than the exclusive serial communication unit.