• 제목/요약/키워드: Complex Conductivity

검색결과 258건 처리시간 0.026초

IMI-O 고분자 LB막의 금속 이온의 착체 농도에 따른 전기특성 및 표면분석 (Surface Analysis and Electrical Properties for Complex with Concentration of Metal ion in LB Ultra-thin Films Using IMI-O Polymer)

  • 정상범;유승엽;박재철;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1711-1713
    • /
    • 2000
  • We fabricated an IMI-O polymer containing an imidazole group that could form a complex structure between the monolayer and the metal ions at the air-water interface. Also, the surface analysis and the electrical properties of metal ion complex of Langmuir-Blodgett (LB) films were investigated by using $\pi$-A isotherms. Atomoic force microscopy (AFM), current-voltage (I-V) measurements. In the $\pi$-A isotherms the molecular area was expanded with $Fe^{3+}$ concentration increase. It is considered that the expansion of molecular area is due to electrostatic repulsion between the polymer chains and hydrophobic increase of ionic strength. In the I-V characteristics, it is found that the limiting area has effects on the change of conductivity. And, the dielectric relaxation time decreased for increase of the $Fe^{3+}$ concentration.

  • PDF

확장된 Born 근사에 의한 시추공간 전자탐사 2.5차원 모델링 (Crosshole EM 2.5D Modeling by the Extended Born Approximation)

  • 조인기;서정희
    • 지구물리와물리탐사
    • /
    • 제1권2호
    • /
    • pp.127-135
    • /
    • 1998
  • 전자탐사에서 Born 근사는 이상체내에서의 전기장을 이상체가 없는 균질 매질에서의 일차장으로 대치하는 방법으로 복잡한 전자기 산란(EM scattering)문제를 근사하는데 널리 사용되고 있는 방법이다. 그러나 Born 근사는 이상체의 전도도가 주변 매질에 비하여 너무 크거나, 이상체의 크기가 클 때는 상당히 부정확한 결과를 나타낸다. 확장된 Born근사법은 이러한 Born근사의 문제점을 해결하기 위하여 제안된 방법으로 이상체내의 전기장을 탈분극 텐서와 일차 전기장의 곱으로 근사하는 방법이다. 한편 전자탐사에 3차원 송신원을 사용하는 2차원 모델링은 주로 유한차분법과 유한요소법이 이용되었다. 일반적으로 이들 미분 방정식을 이용하는 2차원 전자탐사 모델링에서 3차원 송신원 문제의 해결을 위하여 Fourier변환을 통해 파수영역(wavenumber domain)으로 이동하는 방법이 사용되어 왔다. 또한 파수영 역에서 계산된 결과는 Fourier 역변환을 통하여 다시 공간영역(space domain)으로 이동해야 하는 번거로움이 있다. 따라서 이들 방법은 계산시간이 많이 걸리고 이상체가 없는 지역도 미소체로 분할해야 하므로 수치계산시 대량의 기억용량이 필요하다. 본 연구에서는 Born근사의 문제점 및 전자탐사 2차원 모델링시 3차원 송신원 문제를 해결할 수 있는 확장된 Born 근사법에 근거한 전자탐사 2.5차원 모델링 프로그램을 개발하였다. 이 모델링 프로그램을 이용하여 수직 자기 쌍극자를 송신원으로 하는 시추공간 전자탐사법에 대한 2차 자기 장을 계산하고 적분 방정식에 의한 3차원 모델링 결과와 비교, 분석하였다. 모든 주파수 대역에서 확장된 Born근사에 의한 2.5차원 모델링 결과가 3차원 모델링 결과와 잘 일치하고 있다. 그러나 이상체의 전도도와 모암의 전도도 차이가 10배 이상의 경우일 때는 두 반응은 상당한 차이를 보인다. 따라서 본 연구에서 개발된 확장된 Born 근사에 의한 2.5차원 모델링은 이상체와 모암의 전도도 차이가 너무 크지 않을 경우 이상체의 위치 및 형상을 파악하는데 효과적일 것으로 기대된다.

  • PDF

라텍스 입자 크기가 폴리스티렌/탄소나노튜브 나노복합재료의 유변물성 및 전기적 물성에 미치는 영향 (Effect of Latex Particle Size on Rheological and Electrical Properties of Polystyrene/Multi-Walled Carbon Nanotube Nanocomposites)

  • 강명환;노원진;이성재
    • 폴리머
    • /
    • 제35권5호
    • /
    • pp.451-457
    • /
    • 2011
  • 라텍스 기법으로 제조한 폴리스티렌(PS)/다중벽 탄소나노튜브(MWCNT) 나노복합재료의 라텍스 입자 크기에 따른 유변학적, 전기적 물성을 고찰하였다. 나노복합재료는 무유화제 유화중합과 분산중합으로 합성한 단분산 PS 입자에 MWCNT를 초음파 분산시킨 다음 동결건조 과정을 거쳐 제조하였다. PS/MWCNT 나노복합재료는 MWCNT 함량이 증가할수록 점차 네트워크 구조를 형성하여 저장 탄성률, 복소 점도 및 전기 전도도가 급격하게 증가하였다. MWCNT 함량에 따른 저장 탄성률 및 복소 점도 증가 효과는 라텍스 입자 크기가 큰 경우 더욱 뚜렷하였다. 입자 크기에 따른 전기적 물성은 MWCNT 함량에 따라 상이한 경향을 보여 주었는데, 함량이 적은 경우 작은 입자로 제조한 나노복합재료가 높은 전기 전도도를 보여 주었으나 함량이 증가할수록 큰 입자의 경우가 높은 값을 보여 주었다.

염색공장의 흡진율 계측을 위한 복합센서 흡진율 계측 모델 개발 (Development of a complex sensor software for measuring the exhaustion rate of dyeing factories)

  • 이정인;박완기;김상하
    • 전기전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.219-225
    • /
    • 2022
  • 우리나라의 섬유산업 중 염색가공 분야는 에너지 다소비 업종으로, 노동 집약적 특성에 따라 원단위 생산성이 낮고, 대부분 중소·영세기업 특징이 있다. 염색 원단의 불량률이 높아지면 재염색으로 인한 생산단가 상승과 초과 에너지 투입으로 비용이 증가하기 때문에, 불량률을 최소를 통한 생산량 향상이 초점이었다. 또한 고온고압의 환경에서 이루어지는 염색공정은 사고 위험으로 염색기 원단 투입구를 실시간으로 개방할 수 없기 때문에 실시간으로 원단의 염색상태 확인이 어려웠다. 최근에는 염액을 실시간으로 모니터링하는 연구가 활발히 진행중이다. 본 논문에서는 탁도, pH, 전도도 센서를 이용하여 염액의 흡진율을 계측할 수 있는 복합센서 흡진율 모델 및 구성시스템을 제안하였으며, 실험방법소개와 실험결과 분석을 실시하였다.

지하수수질측정망 자료를 활용한 경남 오염우려지역의 지하수 수질 특성 (Groundwater Quality Characteristics of Pollution Concerned Area in Gyeongnam Using Groundwater Quality Monitoring Data)

  • 차수연;서양곤
    • 청정기술
    • /
    • 제27권2호
    • /
    • pp.174-181
    • /
    • 2021
  • 본 연구에서는 경상남도 지역의 오염감시전용측정망의 5년간(2013 ~ 2017) 자료를 이용하여 주오염원과 분기별 지하수 수질특성을 분석하였다. 주오염원은 산업단지지역, 광산·폐광산지역 및 하수처리시설로 구별하였다. 분석 항목은 현장측정 항목(수온, pH, 전기전도도, 용존산소, 산화물환원전위), 양이온 그리고 음이온이었다. 수온과 pH는 주오염원에 따라 크게 변하지 않았다. 양이온과 음이온의 평균농도의 합은 산업단지지역에서 가장 높았고, 하수처리시설 그리고 광산·폐광산지역 순이었다. 산업단지지역에서는 전기전도도의 값이 가장 높았고, 용존산소의 값이 가장 낮았다. 산업단지지역은 나트륨이온이 가장 높은 구성비를 보인 반면 하수처리시설과 광산·폐광산지역에서는 칼슘이온이 가장 높은 값을 나타내었다. 모든 주오염원에서 중탄산염의 농도가 가장 높게 나타났다. 수온, pH 그리고 양이온과 음이온의 농도는 분기마다 크게 다르지 않았다. 수질유형 중 Na-HCO3 유형이 가장 높은 비율을 차지하였으나, 외부 오염의 가능성이 높은 Na-Cl 유형도 오염감시전용측정망의 전체 자료 중 약 20%를 차지하였다.

${Nd_{1-x}}{Sr_x}{Ga_{1-x}}{Mg_x}{O_{3-\delta}$ 고체전해질의 복소임피던스 특성과 전기전도도 (Complex Impedance Characteristics and Electrical Conductivity of ${Nd_{1-x}}{Sr_x}{Ga_{1-x}}{Mg_x}{O_{3-\delta}$ Electrolytes)

  • 유광수
    • 한국세라믹학회지
    • /
    • 제38권4호
    • /
    • pp.325-330
    • /
    • 2001
  • 고상반응법으로 이론 밀도의 약 97%의 소결 밀도를 갖는 N $d_{1-x}$S $r_{x}$G $a_{1-x}$M $g_{x}$ $O_{3{\delta}}$(x=0, 0.03, 0.07, 0.1) 고체전해질을 제조하였다. X선 회절 분석 결과, x=0.03일 때의 X선 회절도는 순수한 NdGa $O_3$와 같았으나, x=0.07, 0.1일 때에는 불순물이 나타났다. 교류 복소임피던스는 4$50^{\circ}C$~90$0^{\circ}C$의 온도 범위에서 공기 중에서 측정하였으며, 각 조성에 대하여 상호 비교 분석하기 위하여 복소비저항 스펙트럼으로 변환하여 해석하였다. 전기전도도는 N $d_{0.93}$S $r_{0.07}$G $a_{0.93}$M $g_{0.07}$ $O_{0.97}$(x=0.07) 시편이 90$0^{\circ}C$에서 6$\times$$10^{-3}$ S$cm^{-1}$ /로 가장 우수하였으며, 활성화 에너지는 저온 영역에서는 1 eV, 고온 영역에서는 0.74 eV이었다.다.

  • PDF

Electrocardiography as an early cardiac screening test in children with mitochondrial disease

  • Baik, Ran;Chae, Jung-Hyun;Lee, Young-Mock;Kang, Hoon-Chul;Lee, Joon-Soo;Kim, Heung-Dong
    • Clinical and Experimental Pediatrics
    • /
    • 제53권5호
    • /
    • pp.644-647
    • /
    • 2010
  • Purpose: To evaluate myocardial conductivity to understand cardiac involvement in patients with mitochondrial disease. Methods: We performed retrospective study on fifty-seven nonspecific mitochondrial encephalopathy patients with no clinical cardiac manifestations. The patients were diagnosed with mitochondrial respiratory chain complex defects through biochemical enzyme assays of muscle tissue. We performed standard 12-lead electrocardiography (ECG) on all patients. Results: ECG abnormalities were observed in 30 patients (52.6%). Prolongation of the QTc interval (>440 ms) was seen in 19 patients (33.3%), widening of the corrected QRS interval in 15 (26.3%), and bundle branch block in four (7.0%). Atrioventricular block, premature atrial contraction and premature ventricular contraction were seen in two patients each (3.5%) and Wolff-Parkinson-White syndrome in one patient (1.8%). Conclusion: Given this finding, we recommend active screening with ECG in patients with mitochondrial disease even in patients without obvious cardiac manifestation.

The thermal impedance spectroscopy on Li-ion batteries using heat-pulse response analysis

  • Barsoukov Evgenij;Jang Jee Hwan;Lee Hosull
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2001년도 전지기술심포지움
    • /
    • pp.145-161
    • /
    • 2001
  • Novel characterization of thermal properties of a battery has been introduced by defining its frequency-dependent thermal impedance function. Thermal impedance function can be approximated as a thermal impedance spectrum by analyzing experimental temperature transient which is related to the thermal impedance function through Laplace transformation. In order to obtain temperature transient, a process has been devised to generate external heat pulse with heating wire and to measure the response of battery. This process is used to study several commercial Li-ion batteries of cylindrical type. The thermal impedance measurements have been performed using potentionstat/galvanostate controlled digital signal processor, which is more commonly available than flow-meter usually applied for thermal property measurements. Thermal impedance spectra obtained for batteries produced by different manufactures are found to differ considerably. Comparison of spectra at different states of charge indicates independence of thermal impedance on charging state of battery. It is shown that thermal impedance spectrum can be used to obtain simultaneously thermal capacity and thermal conductivity of battery by non-linear complex least-square fit of the spectrum to thermal impedance model. Obtained data is used to simulate a response of the battery to internal heating during discharge. It is found that temperature inside the battery is by one-third larger that on its surface. This observation has to be considered to prevent damage by overheating.

  • PDF

금속이온 농도에 의한 고분자 LB막의 전자 특성 (Electronic Properties of Polymer LB Films for the Metal Ion Concentration)

  • 박재철;정상범;유승엽
    • 대한전자공학회논문지TE
    • /
    • 제37권2호
    • /
    • pp.1-5
    • /
    • 2000
  • 금속이온 농도를 변화시켰을때의 IMI-O 고분자 LB막에 대한 단분자막의 거동과 MIM구조의 LB막 소자에 대한 전기 특성 및 유전 특성을 조사하였다. π-A 등온선의 측정에서 금속 이온 농도가 증가함에 따라 단분자가 차지하는 극한 단면적이 증가하였다. 이러한 변화는 금속이온 농도 변화에 따른 금속이온의 강도 증가에 의한 단분자막의 거동의 차이에 의한 것으로 생각된다. 전압-전류 특성에서 ohmic 영역의 기울기로부터 구한 전기전도도는 금속 이온의 농도가 증가할 수록 증가하였다. 이것은 전개분자와 금속이온간의 결합에 의한 극한 단면적의 변화가 전기전도도에 직접적인 관계가 있기 때문으로 생각된다. 한편, 유전 특성에서 금속이온의 농도가 증가할 수록 허수부 유전율이 최대가 되는 주파수 역시 증가하였다. 따라서 금속이온의 증가에 의해 완화시간 γ가 감소되는 것을 알 수 있었다.

  • PDF

Nafion-Sulfonated Poly(arylene ether sulfone) Composite Membrane for Direct Methanol Fuel Cell

  • Choi Jisu;Kim II Tae;Kim Sung Chul;Hong Young Taik
    • Macromolecular Research
    • /
    • 제13권6호
    • /
    • pp.514-520
    • /
    • 2005
  • Composite membranes of Nafion and sulfonated poly(arylene ether sulfone) were prepared. Sulfonated poly(arylene ether sulfone)s with different degrees of sulfonation were blended with Nafion to reduce the methanol crossover. The morphology, proton conductivity and methanol permeability of the resulting composite membranes were investigated by SEM, EDAX, AC impedance spectroscopy and permeability measuring instrument. The cross­sections of the composite membranes showed a phase separated morphology. The morphology and phase separation mechanism could be controlled by varying the blend ratio and the degree of sulfonation of poly(arylene ether sulfone). These complex morphologies can be applied for reducing methanol crossover. The methanol permeability and proton conductivity of the composite membranes were lower than those of Nafion 117 membrane since the development of an ionic pathway in the blend membrane was more difficult than that in Nafion itself.