• 제목/요약/키워드: Comparison of efficiency

검색결과 3,222건 처리시간 0.029초

박격포의 형상에 따른 열적 내구성의 해석에 대한 연구 (A Study on the Analysis of Thermal Durability due to the Configuration of Mortar)

  • 한문식;조재웅
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.69-76
    • /
    • 2015
  • This study investigates the thermal efficiency and the efficiency of heat transfer through thermal analysis when the same heat is applied to a mortar frame by firing with various configurations of mortar. As the inside diameter of the mortar increases, the additional material must be reinforced. In comparison with the extent of getting cold due to models, a mortar with the strut under the gun barrel becomes cooler than one with no strut. The thermal deformation at firing becomes different. According to the configuration of mortar and its inside diameter, the extent of getting cold becomes different. This study result can be effectively applied for improving the efficiency of the heat transfer of mortar.

공기 엔진의 에너지 효율 평가 (Evaluation of the Energy Efficiency of the Air Engine)

  • 박재현;백제현
    • 한국자동차공학회논문집
    • /
    • 제23권5호
    • /
    • pp.494-501
    • /
    • 2015
  • Nowadays, many people are trying to develop eco-friendly engines such as the electric motor and the air engine because the I.C. engine cause a lot of pollutants. Nevertheless of these effort, there are few evaluation and comparison of these engines to conventionally used I.C. engines. Because of this, it is difficult to determine that the eco-friendly engines are really energy saving engines. In this paper, the efficiency of the air engine is calculated. The air engine does not cause environmental pollution problem because it uses "Compressed air". Due to the air engine operated at a low temperature and spark-free condition, this engine can be used in extreme condition for safety. Despite the many advantages of the air engine, there are few analysis on the air engine because of an air engine is low energy density.

렌즈에 따른 광콜리메이터 성능 비교 분석 (Analysis add Comparison of the Performance of Optical Collimator by Lenses)

  • 선화영;최두선;제태진;최기봉;김동식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.132-136
    • /
    • 2002
  • Optical collimating lenses are play a role as maintenance parallel light and as a kind of optical collimating lens, there is Ball lenses, GRIN-rod lenses, spherical lenses and aspherical lenses etc. but recently GRIN lens has monopolized a market. The performance of optical collimator depended on the coupling efficiency. In this paper, we were compared and analyzed to be measured values of coupling efficiency with respect to optical working distance using GRIN rod lenses and spherical lenses. In the case of GRIN lenses with a beam size of 420 ${\mu}{\textrm}{m}$, the minimum coupling efficiency was obtained to a measured value of 0.15 ㏈ and in the case of spherical lenses was obtained to a measured value of 0.12 ㏈ on the same condition. In results, we found that a performance of spherical lenses be better as compared with a that of GRIN lens.

  • PDF

대칭 사다리꼴 핀과 비대칭 사다리꼴 핀의 성능 비교 (Comparison of Performance between Symmetric Trapezoidal Fins and Asymmetric Trapezoidal Fins)

  • 강형석
    • 한국자동차공학회논문집
    • /
    • 제24권2호
    • /
    • pp.205-213
    • /
    • 2016
  • Heat loss and fin efficiency of symmetric and asymmetric trapezoidal fins with variable slope of fin's top surface are obtained by using a two-dimensional analytic method. Shapes of symmetric and asymmetric fins are changed from rectangular through trapezoidal to triangular by adjusting the fin shape factor. The ratio of symmetric trapezoidal fin length to asymmetric trapezoidal fin length is presented as a function of fin base height and convection characteristic number. The ratio of symmetric trapezoidal fin efficiency to asymmetric trapezoidal fin efficiency is presented as a function of the fin base height and fin shape factor. One of results shows that asymmetric trapezoidal fin length is shorter than symmetric trapezoidal fin length (i.e., asymmetric trapezoidal fin volume is smaller than symmetric trapezoidal fin volume) for the same heat loss when the fin base height and fin shape factor are the same.

정수 측정 시험에 의한 고효율 유도 전동기의 손실 특성 비교 (Comparison of Loss Characteristics of High-Efficiency Induction Motor by Parameter Measurement Test)

  • 변한섭;김성철;양성한;한성진;주수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.318-320
    • /
    • 1999
  • Electric motor transforms electric power into mechanical power. It is important to increase efficiency of motor to save energy and to decrease operating cost. In this paper, some parameters and losses of high-efficiency induction motor and standard induction motor are measured by blocked-rotor test and no-load test. Operational parameters of high-efficiency induction motor that are compared with those of standard motor.

  • PDF

Comparative Study on 220V AC Feed System and 300V DC Feed System for Internet Data Centers

  • Kim, Hyo-Sung
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.157-163
    • /
    • 2012
  • Internet Data Centers (IDCs), which are essential facilities in the modern IT industry, typically have scores of MW of concentrated electric loads. The provision of an Uninterruptible Power Supply (UPS) is necessary for the power feed system of IDCs owing to the need for stable power. Thus, conventional IDC AC power feed systems have three cascaded power conversion stages, (AC-DC), (DC-AC), and (AC-DC), resulting in a very low conversion efficiency. In comparison, DC power feed systems require only a single power conversion stage (AC-DC) to supply AC main power to DC server loads, resulting in comparatively high conversion efficiency and reliability [4-11]. This paper compares the efficiencies of a 220V AC power feed system with those of a 300V DC power feed system under equal load conditions, as established by the Mok-Dong IDC of Korea Telecom Co. Ltd. (KT). Experimental results show that the total operation efficiency of the 300V DC power feed system is approximately 15% higher than that of the 220V AC power feed system.

부분 포스트텐션닝 방법에 의해 연속화된 교량의 주형단면 (Girder Section of Continuous Bridges Spliced by Partial Post-Tensioning)

  • 이환우;곽효경;송영용
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.43-50
    • /
    • 2000
  • In this paper, a new splicing method was applied to design the girder section of bridges with the span length of 25m, 30m, 35m, 40m and 45m. A U-type precast prestressed section was also determined for each bridge. Additionally, the sectional area, beam depth and Guyon's efficiency factor of the spliced U-type sections in each span were analyzed in comparison with the present I-type PSC bridges. As a result, in spite of an increase of 31%∼50% in the sectional areas compared with the I-type precast girders, the spliced U-type the beam depth of the spliced U-type girder was designed as 2,050 mm compared with the I-type precast girder of 2,600mm in a 40m span bridge. The sectional efficiency factors of the spliced U-type sections were analyzed as 0.76∼0.99. It shows that the spliced U-type sections ar of a superior structural efficiency in contrast to the average sectional efficiency factor of 0.66 value in the I-type girders.

전기자동차 구동시스템에서의 유도전동기의 최대효율제어 효과(II) (An Effect of Maximizing Efficiency Control of Induction Motor for Electric Vehicle Drive Systems(II))

  • 최욱돈;김동희;노채균
    • 조명전기설비학회논문지
    • /
    • 제14권5호
    • /
    • pp.74-79
    • /
    • 2000
  • 본 논문에서는 유도전동기의 손실을 고려한 최대 효율제어기법을 전기자동차 구동시스템에 적용하고, 그 효과를 검증하기 위해 최대 효율제어를 적용하였을 때와 기존의 일정자속 제어방식을 적용하였을 경우에 대해 각각 ­미국의 F.T.P-72와 E.P.A의 HWFET(Highway Fuel Effciency Test)에서 정한 시내 주행모드(LA-4 Mode) 와 고속 주행 모드에서의 주행시험을 통해 그 결과를 비교 제시하였다. 또한 시험을 통해 전기자동차의 주행거리 증대를 위해 최대 효율제어 적용시 효과를 검토하였다.

  • PDF

Auxiliary Address Pulse Driving Scheme for Improving Luminance and Luminous Efficiency in 42-inch WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.16-21
    • /
    • 2004
  • The effects of an auxiliary address pulse driving scheme, in which an auxiliary short pulse is applied to the address electrode during a sustain-period, were examined under the various image patterns of the 42-inch WVGA ac-PDP. When the auxiliary address pulse driving scheme was applied, the luminance of the red, green and blue cells were measured respectively. And the luminance, luminous efficiency, and current were measured under the full-white pattern of the 42-inch ac-PDP. As a result, the luminance of blue cells was improved approximately by 17 %, whereas the luminous efficiency of the full-white pattern was improved approximately by 34 % without a misfiring discharge in comparison with conventional driving scheme.

원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교 (Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System)

  • 김상도;박영옥;강용
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.