• Title/Summary/Keyword: Comparison Model

Search Result 8,772, Processing Time 0.038 seconds

Impacts of Argo temperature in East Sea Regional Ocean Model with a 3D-Var Data Assimilation (동해 해양자료동화시스템에 대한 Argo 자료동화 민감도 분석)

  • KIM, SOYEON;JO, YOUNGSOON;KIM, YOUNG-HO;LIM, BYUNGHWAN;CHANG, PIL-HUN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.20 no.3
    • /
    • pp.119-130
    • /
    • 2015
  • Impacts of Argo temperature assimilation on the analysis fields in the East Sea is investigated by using DAESROM, the East Sea Regional Ocean Model with a 3-dimensional variational assimilation module (Kim et al., 2009). Namely, we produced analysis fields in 2009, in which temperature profiles, sea surface temperature (SST) and sea surface height (SSH) anomaly were assimilated (Exp. AllDa) and carried out additional experiment by withdrawing Argo temperature data (Exp. NoArgo). When comparing both experimental results using assimilated temperature profiles, Root Mean Square Error (RMSE) of the Exp. AllDa is generally lower than the Exp. NoArgo. In particular, the Argo impacts are large in the subsurface layer, showing the RMSE difference of about $0.5^{\circ}C$. Based on the observations of 14 surface drifters, Argo impacts on the current and temperature fields in the surface layer are investigated. In general, surface currents along the drifter positions are improved in the Exp. AllDa, and large RMSE differences (about 2.0~6.0 cm/s) between both experiments are found in drifters which observed longer period in the southern region where Argo density was high. On the other hand, Argo impacts on the SST fields are negligible, and it is considered that SST assimilation with 1-day interval has dominant effects. Similar to the difference of surface current fields between both experiments, SSH fields also reveal significant difference in the southern East Sea, for example the southwestern Yamato Basin where anticyclonic circulation develops. The comparison of SSH fields implies that SSH assimilation does not correct the SSH difference caused by withdrawing Argo data. Thus Argo assimilation has an important role to reproduce meso-scale circulation features in the East Sea.

Comparison study of dermal cell toxicity and zebrafish brain toxicity by humidifier sterilizer chemicals (PHMG, PGH, CMIT/MIT) (가습기 살균제 성분(PHMG, PGH, CMIT/MIT)의 사람 피부세포 독성 및 제브라피쉬 뇌신경 독성 비교 연구)

  • Cho, Kyung-Hyun;Kim, Jae-Ryong
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.2
    • /
    • pp.271-277
    • /
    • 2020
  • Toxicities to many organs caused by humidifier disinfectants have been reported. Recently, humidifier disinfectants have been reported to cause cardiovascular, embryonic, and hepatic toxicities. This study was designed to investigate the toxic mechanism of humidifier disinfectants and compare toxicity in a cellular model and a zebrafish animal model. Because brain toxicity and skin toxicity have been less studied than other organs, we evaluated toxicity in a human dermal cell line and zebrafish under various concentrations of humidifier disinfectants that included polyhexamethyleneguanidine phosphate (PHMG), oligo-[2-(2-ethoxy)-ethoxyethyl-guanidinium-chloride] (PGH) and methylchloroisothiazolinone/methylisothiazolinone (CMIT/MIT). A human dermal fibroblast cell line was treated with disinfectants (0, 2, 4, 6, 8, and 16 mg L-1) to compare their cytotoxicity. The fewest PHMG-treated cells survived (up to 33%), while 49% and 40% of the PGH- and CMIT/MIT-treated cells, respectively, survived. The quantification of oxidized species in the media revealed that the PHMG-treated cells had the highest MDA content of around 28 nM, while the PGH- and CMIT/MIT-treated cells had 13 and 21 nM MDA, respectively. As for brain toxicity, treatment of the zebrafish tank water with CMIT/MIT (final 40 mg L-1) for 30 min resulted in a 17-fold higher production of reactive oxygen species (ROS) than in the control. Treatment with PGH or PHMG (final 40 mg L-1) resulted in 15- and 11-fold higher production, respectively. The humidifier disinfectants (PHMG, PGH, and CMIT/MIT) showed severe dermal cell toxicity and brain toxicity. These toxicities may be relevant factors in understanding why some children have language disorders, motor delays, and developmental delays from exposure to humidifier disinfectants.

Development and Comparison of Growth Regression Model of Dry Weight and Leaf Area According to Growing Days and Accumulative Temperature of Chrysanthemum "Baekma" (국화 "백마"의 생육 일수 및 누적 온도에 따른 건물중과 엽면적의 생장 회귀 모델 개발 및 비교)

  • Kim, Sungjin;Kim, Jeonghwan;Park, Jongseok
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.414-420
    • /
    • 2020
  • This study was carried out to investigate the growth characteristics of standard chrysanthemum 'Baekma', such as fresh weight, dry weight, and leaf area and to develop prediction models for the production greenhouse based on the growth parameters and climatic elements. Sigmoid regressions models for the prediction of growth parameters in terms of dry weight and leaf area were analyzed according to the number of the day after transplanting and the accumulate temperature during this experimental period. The relative growth rate (RGR) of the chrysanthemum was 0.084 g·g-1·d-1 on average during the period.The dry weight and leaf area of 'Beakma' increased exponentially according to the number of day after transplanting and the accumulated temperature, in the case of dry weight increased by an average of 39.1% until 63 days (accumulated temperature of 1601℃), after that dry weight increased by an average of 7.4% before harvest. The leaf area increased by an average of 63.3% until the 28th day after transplanting, and by an average of 6.5% until the 84th day before flower bud differentiation occurred, and increased by an average of 10.6% before harvest. This experiment can be used as a useful data for establishing a cultivation management system and a planned year-round production system for standard chrysanthemum "Baekma". To make a more precise growth prediction model, it will need to be corrected and verified based on various weather data including accumulated irradiation.

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Technical Efficiency of Medical Resource Supply and Demand (의료자원 공급, 수요의 성과 효율성에 대한 실증분석)

  • Chang, Insu;Ahn, Hyeong Seok;Kim, Brian H.S.
    • Journal of the Korean Regional Science Association
    • /
    • v.34 no.2
    • /
    • pp.3-19
    • /
    • 2018
  • The objective of this study is to observe the efficiency of clinical performance on the supply and demand of medical resources in Korea. For the empirical analysis, we constructed the dataset on age standardized mortality rate, the number of physician, specialist, surgery, medical institution, ratio of general hospitals of 16 provinces in Korea from 2006 to 2013. The panel probability frontier model is employed as an analysis method and considered heteroscedasticity and autocorrelation of the error in panel data. In addition, the demographic and socioeconomic characteristics of the 16 provinces, unemployment rate, elderly population ratio, GRDP per capita, and ratio of hospitals in comparison to the general hospitals are used to find the effect on the technical efficiency of clinical performance on supply and demand of medical resources. The results are as follows. First, for the clinical performance, the supply side of human resources such as doctors and specialists and the demand side factors such as chronic illness clinic per unit population have a significant influence, respectively. Second, the technical efficiency of clinical performance on the supply and demand of medical resources of each input component was 59-70% in terms of clinical efficiency in each region. Third. estimates of technical efficiency of inputs that affect clinical performance showed a slight increase in all regions during the analysis period, but the increase trend decreased slightly. Fourth, the ratio of the elderly population and GRDP per capita have a positive influence on the technical efficiency of clinical performance on the supply and demand of medical resources. The difference of each efficiency by region is due to the regional differences of the input medical resources and the combination of them and the demographic and socioeconomic characteristics of the region. It is understood that the differences in technological efficiency due to the complexity of supply and demand of medical resources, demographic structure and economic difference affecting clinical performance by region are different.

Methods for Genetic Parameter Estimations of Carcass Weight, Longissimus Muscle Area and Marbling Score in Korean Cattle (한우의 도체중, 배장근단면적 및 근내지방도의 유전모수 추정방법)

  • Lee, D.H.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.4
    • /
    • pp.509-516
    • /
    • 2004
  • This study is to investigate the amount of biased estimates for heritability and genetic correlation according to data structure on marbling scores in Korean cattle. Breeding population with 5 generations were simulated by way of selection for carcass weight, Longissimus muscle area and latent values of marbling scores and random mating. Latent variables of marbling scores were categorized into five by the thresholds of 0, I, 2, and 3 SD(DSI) or seven by the thresholds of -2, -1, 0,1I, 2, and 3 SD(DS2). Variance components and genetic pararneters(Heritabilities and Genetic correlations) were estimated by restricted maximum likelihood on multivariate linear mixed animal models and by Gibbs sampling algorithms on multivariate threshold mixed animal models in DS1 and DS2. Simulation was performed for 10 replicates and averages and empirical standard deviation were calculated. Using REML, heritabilitis of marbling score were under-estimated as 0.315 and 0.462 on DS1 and DS2, respectively, with comparison of the pararneter(0.500). Otherwise, using Gibbs sampling in the multivariate threshold animal models, these estimates did not significantly differ to the parameter. Residual correlations of marbling score to other traits were reduced with comparing the parameters when using REML algorithm with assuming linear and normal distribution. This would be due to loss of information and therefore, reduced variation on marbling score. As concluding, genetic variation of marbling would be well defined if liability concepts were adopted on marbling score and implemented threshold mixed model on genetic parameter estimation in Korean cattle.

A Study on the Efforts of Technological Innovation by Academia-Industrial Collaboration for Venture Businesses (산학협력이 중소벤처기업의 기술혁신성과에 미치는 영향에 관한 연구)

  • Song, Geon-Ho;Lee, Cheol-Gyu;Yoo, Wang-Jin;Lee, Dong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3340-3353
    • /
    • 2009
  • This paper aims to study the effect of academia-industrial cooperation on the technical innovation of small and medium-sized companies. A survey was conducted on about 1,100 businesses located in the Sihwa-Banwol industrial estate to analyze the consequence of three factors of academia-industrial cooperation. the joint use of equipments, technological support of universities to businesses, and cooperative technological development through technical guidance-on entrepreneurial capability and their knowledge-absorption ability, and ultimately on their technological innovation,. The validity of the survey result was tested through the Structural Equation Model. On the basis of the comparison between companies which have participated in academy-industry cooperation and companies which have not, this paper suggests that venture businesses should take advantage of the cooperation with universities to boost their competitiveness. The analysis of the three individual factors of the academy-industry cooperation based on the Structural Equation Model shows that all of them have remarkable influence on entrepreneurial capability, but that they don't have as much impact on businesses' knowledge absorption ability. However, the outcome of technological innovation of businesses is primarily influenced by entrepreneurial capability rather than their knowledge absorption ability. The survey also shows that the three factors of the cooperation have an equal impact on the competitiveness of companies regardless of their business type or their products' growth stages. As the companies involved in academy industry cooperation outweigh other businesses, in terms of technological innovation, the numbers of new product development, and the numbers of their process improvement cases, this paper argues that new strategies should be taken for the businesses to fully take advantage of academy-industry cooperation.

Interannual and Seasonal Variations of Water Quality in Terms of Size Dimension on Multi-Purpose Korean Dam Reservoirs Along with the Characteristics of Longitudinal Gradients (우리나라 다목적댐 인공호들의 규모에 따른 연별.계절별 수질변이 및 상.하류간 종적구배 특성)

  • Han, Jeong-Ho;Lee, Ji-Yeoun;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.319-337
    • /
    • 2010
  • Major objective of this study was to determine interannual and seasonal water quality along with characteristics of longitudinal gradients along the reservoir axis of the riverine zone (Rz)-to-lacustrine zone (Lz). Water quality dataset of five years during 2003~2007 used here were obtained from Ministry of Environment, Korea and ten physical, chemical and biological parameters were analyzed in the study. Similarity analysis, based on moropho-hydrological variables of reservoir surface area, watershed area, total inflow, and outflow, showed that the reservoirs were categorized as three groups of large-dam reservoirs (Chungju Reservoir, Daecheong Reservoir and Soyang Reservoir), mid-size reservoirs (Andong Reservoir, Yongdam Reservoir, Juam Reservoir and Hapcheon Reservoir), and small-size reservoirs (Hoengseong Reservoir and Buan Reservoir). According to the data comparison of high-flow year (2003) vs. lowflow year (2005), dissolved oxygen (DO), pH, biological oxygen demand (BOD), suspended solids (SS), total nitrogen (TN), total phosphorus (TP), chlorophyll-a (CHL) and electrical conductivity (EC) declined along the longitudinal axis of Rz to Lz and water transparency, based on Secchi depth (SD), increased along the axis. These results indicate that transparency was a function of Values of pH, DO, SS, SD, and EC at each site were greater in the low-flow year (2005) than the high-flow year (2003), whereas values of BOD, COD, TN, TP and CHL were greater in the high-flow year (2003). When values of TN, TP, CHL and SD in nine reservoirs were compared in the three zones of Rz, Tz, and Lz, values of TN, TP and CHL declined along longitudinal gradients and SD showed the opposite due to the sedimentation processes from the water column. Values of TN were not statistically correlated with TP values. The empirical linear models of TP-CHL and CHL-SD showed significant (p<0.05, $R^2$>0.04). In the mid-size reservoirs, the variation of CHL was explained ($R^2$=0.2401, p<0.0001, n=239) by the variation of TP. The affinities in the correlation analysis of mid-size reservoirs were greater in the CHL-SD model than any other empirical models, and the CHL-SD model had an inverse relations. In the meantime, water quality variations was evidently greater in Daecheong Reservoir than two reservoirs of Andong Reservoir and Hoengseong Reservoir as a result of large differences of water quality by long distance among Rz, Tz and Lz.

BIOMECHANICS OF ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES UNDER UNILATERAL LOADING

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Jeong-Taek;Roh, Hyun-Ki;Kim, Hyo-Jin;Lee, Seok-Hyung;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.753-759
    • /
    • 2007
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading specially. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs under unilateral loading, using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1: Clasp-retained mandibular removable partial denture with unsplinted abutments Group 2: Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge. Group 3: Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm dose to the abutments. Two unilateral vertical experimental loadings (30N and 100N) were applied subsequently via miniature load cell that were placed at mandibular left first molar region. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Tukey test was used as post hoc comparisons. Results. The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Strain values increased as the applied load in increased from 30N to 100N (p<.05) except for right side in group 1. Under 30N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 100N loading in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 30N loading, group 2 and 3 showed higher strain values in right side than in left side. Under 100N loading, right side strain values were higher than left side ones for all groups. Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments under unilateral loading. Bar-retained removable partial denture showed the lowest strain of three groups, and compressive nature.